PubMed Health⌕ Search

Biomedical subjects

S A Taylor

Publications and source records attributed to S A Taylor.

At least 19 recordsLinked to original sources

CT colonography: automatic measurement of polyp diameter compared with manual assessment - an in-vivo study.

AIM: To investigate whether automated diameter assessment was feasible for CT colonography. MATERIALS AND METHODS: Two experienced observers independently measured the maximum diameter of 50 polyps (colonoscopic reference size range 5-12 mm) from colonography datasets using conventionally placed software callipers and a variety of two-dimensional (2D) computed tomography (CT) window settings (colon, abdominal, bone, lung), and also three-dimensional (3D) perspective rendering. Polyps were also measured using automated polyp-segmentation software. Agreement between observers and with the colonoscopic reference measurement was determined using Bland-Altman, Wilcoxon, and Mann-Whitney U analyses. RESULTS: Inter-observer agreement was similar for all window displays: mean difference in millimetres (SD difference; 95% limits of agreement) ranged from 0 (1.7, -3.3, 3.3) for 2D colon to -1.1mm (1.6, -4.3, 2.0) for 3D, compared with -0.5 (2.09, -4.6, 3.6) for automated measurement. When compared to colonoscopy, the largest discrepancy occurred using the 3D display (mean difference 1.3mm, 2.5mm for each observer). There was also a significant difference between estimates and reference size when using the 2D abdominal and 3D displays (p=0.03, <0.001). CONCLUSION: Automated polyp measurement is possible in vivo. Automated and conventional methods have comparable inter-observer agreement. The greatest measurement error is encountered when using a 3D display for estimates of diameter.

Colon↗

In vitro production of llama (Lama glama) embryos by intracytoplasmic sperm injection: effect of chemical activation treatments and culture conditions.

Assisted reproductive technologies in the llama (Lama glama) are needed to provide alternative methods for the propagation, selection and genetic improvement; however, recovery of adequate quantity and quality of spermatozoa for conventional IVF is problematic. Therefore, an effort was made to adapt the intracytoplasmic sperm injection (ICSI) procedure for the in vitro production of llama embryos. The specific objectives of this study were: (1) to determine in vitro maturation rates of oocytes recovered by transvaginal ultrasound-guided oocyte aspiration (TUGA) or flank laparotomy; (2) to evaluate the effects of activation treatments following ICSI; (3) to evaluate the development of llama ICSI embryos in CR1aa medium or in an oviduct cell co-culture system. Llamas were superstimulated by double dominant follicle reduction followed by oFSH administered in daily descending doses over a 3-day interval. Oocytes were harvested by flank laparotomy or TUGA and matured in vitro for 30 h. Mature oocytes were subjected to ICSI followed by no chemical activation (Treatment A), ionomycin only (Treatment B) or ionomycin/DMAP activation (Treatment C). More oocytes were recovered by flank laparotomy procedure compared with TUGA (94% versus 61%, P<0.05) and a greater number of oocytes harvested by flank laparotomy reached the metaphase-II stage (77% versus 44%, P<0.05). After ICSI, the proportion of cleaved and 4-8-cell stages embryos was significantly greater when injected oocytes were activated with ionomycin/DMAP combination (63% and 38%, respectively, P<0.05). The co-culture of ICSI embryos with llama oviduct epithelial cells resulted in progression to morula (25%) and blastocyst (12%) stages; whereas, all embryos cultured in CR1aa medium arrested at the 8-16-cell developmental stage.

Animals↗

Distance between the rectal wall and mesorectal fascia measured by MRI: Effect of rectal distension and implications for preoperative prediction of a tumour-free circumferential resection margin.

AIM: To determine the effect of rectal distension, used by some workers to facilitate staging, on mesorectal tissues. SUBJECTS AND METHODS: Ninety-seven consecutive rectal cancer staging MRI examinations were identified of which 76 were analysable: 48 studies were performed using rectal insufflation of 100 ml room air and 28 were performed without distension. Median age was 69 and 72 years, respectively. In each patient a single experienced observer measured the distance from the outer rectal wall to the inner margin of the mesorectal fascia at four locations (12, 3, 6 and 9 o'clock), excluding sites of tumour involvement, from the T1-weighted axial image at the level of the sacro-coccygeal junction. The two groups of measurements were compared using Mann-Whitney test statistic, and frequencies then categorized into <5 mm or > or =5 mm, and compared using Fisher's exact test. RESULTS: The median distance between the rectal wall and mesorectal fascia in the distended group was approximately half that found in the non-distended group, and significantly lower at the 3, 6 and 9 o'clock positions (p<0.001). 68/167 (41%) of measurements were 5mm or less, compared with 19/104 (18%) in the non-distended group (p<0.001). CONCLUSION: Rectal distension before MRI significantly reduces the distance between the rectal wall and mesorectal fascia. Although this is advocated to facilitate visualization of the primary tumour, it potentially affects the accuracy with which a clear circumferential resection margin can be predicted.

Aged↗

Computer-assisted detection for CT colonography: external validation.

AIM: To externally validate a computer-assisted detection (CAD) system for computed tomography (CT) colonography, using data from a single centre uninvolved with the software development. MATERIALS AND METHODS: Twenty-five multi-detector CT colonography examinations of patients with validated polyps accumulated at a single centre were examined by two readers who used endoscopic and histopathological data to identify polyp coordinates. A CAD system that had been developed using data from elsewhere, and had not previously encountered the present data, was then applied to the data at sphericity filter settings of 0.75 and 0.50 and identified potential polyps. True-positive, false-negative, and false-positive counts were determined by comparison with the known polyp coordinates. RESULTS: Twenty-five patients had 57 polyps, median size 6mm (range 1-15mm). Per-patient sensitivity for the CAD system was 96% (24 of 25). The CAD system detected 44 (77%) polyps at sphericity setting 0.75 and 49 (86%) polyps at sphericity 0.50: the additional five polyps detected all measured 5mm or less. Sphericity of 0.75 resulted in a median of 10 (one to 34) easily dismissed false-positive prompts per patient and a median of 4 (zero to 15) that needed three-dimensional rendering before dismissal. This rose to 32 (16 to 99) and 11 (three to 35), respectively, at sphericity 0.5. CONCLUSIONS: A per-patient sensitivity of 96% was found for the CAD system (in patients with a median polyp diameter of 6mm) using external validation, a more stringent test than either internal cross-validation or temporal validation. Decreasing sphericity increases sensitivity for small polyps at the expense of decreased specificity.

Colonic Polyps↗

Comparison of radiologists' confidence in excluding significant colorectal neoplasia with multidetector-row CT colonography compared with double contrast barium enema.

The aim of this study was to compare the confidence of experienced radiologists in excluding colonic neoplasia with CT colonography (CTC) compared with barium enema. 78 patients (median age 70 years, range 61-87 years, 44 women) underwent same day CTC and barium enema. Two radiologists experienced in reporting barium enema assessed whether the examination had excluded a polyp 6 mm or greater as "yes", "probably" or "no" for each of 6 colonic segments. Two different radiologists experienced in CTC independently performed the same assessment on the CT datasets. Responses were compared using a paired exact test. Formal barium enema and CT reports were compared with any endoscopic examination performed within 1 year. Studies reporting polyps 6 mm+ in patients not subsequently undergoing endoscopy were reviewed by two independent observers. Radiologists stated they had confidently excluded a significant lesion in 314 (71%) and 382 (86%) of 444 segments with barium enema and CTC, respectively (p<0.001). Confidence was significantly higher with CTC in the in the descending and ascending colon (p = 0.02 and p<0.001, respectively), and caecum (p<0.001). 22 patients underwent some form of endoscopy. Of five patients with proven colorectal neoplasia (including two with cancer), CTC and barium enema correctly identified five and three, respectively. In 56 patients not undergoing endoscopy, CTC reported 17 polyps 6 mm+, of which 16 were retrospectively classified as definite or probable. 11 could not be identified on the barium enema, even in retrospect. Confidence in excluding polyps 6 mm or larger is significantly greater with CT colonography particularly in the proximal colon.

Aged↗

Ghrelin enhances gastric emptying in diabetic gastroparesis: a double blind, placebo controlled, crossover study.

BACKGROUND: Diabetic gastroparesis is a disabling condition with no consistently effective treatment. In animals, ghrelin increases gastric emptying and reverses postoperative ileus. We present the results of a double blind, placebo controlled, crossover study of ghrelin in gastric emptying in patients with diabetic gastroparesis. METHODS: Ten insulin requiring diabetic patients (five men, six type I) referred with symptoms indicative of gastroparesis received a two hour infusion of either ghrelin (5 pmol/kg/min) or saline on two occasions. Blood glucose was controlled by euglycaemic clamp. Gastric emptying rate (GER) was calculated by real time ultrasound following a test meal. Blood was sampled for ghrelin, growth hormone (GH), and pancreatic polypeptide (PP) levels. Cardiovagal neuropathy was assessed using the Mayo Clinic composite autonomic severity score (range 0 (normal)-3). RESULTS: Baseline ghrelin levels were mean 445 (SEM 36) pmol/l. Ghrelin infusion achieved a peak plasma level of 2786 (188) pmol/l at 90 minutes, corresponding to a peak GH of 70.9 (19.8) pmol/l. Ghrelin increased gastric emptying in seven of 10 patients (30 (6)% to 43 (5)%; p = 0.04). Impaired cardiovagal tone correlated inversely with peak postprandial PP values (p < 0.05) but did not correlate with GER. CONCLUSIONS: Ghrelin increases gastric emptying in patients with diabetic gastroparesis. This is independent of vagal tone. We propose that analogues of ghrelin may represent a new class of prokinetic agents.

Adult↗

Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema.

AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p = 0.03) and overall satisfaction was greater compared with barium enema (p = 0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p = 0.002), and were less prepared to undergo barium enema again (p < 0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

Aged↗

Comparative mapping between Medicago sativa and Pisum sativum.

Comparative genome analysis has been performed between alfalfa (Medicago sativa) and pea (Pisum sativum), species which represent two closely related tribes of the subfamily Papilionoideae with different basic chromosome numbers. The positions of genes on the most recent linkage map of diploid alfalfa were compared to those of homologous loci on the combined genetic map of pea to analyze the degree of co-linearity between their linkage groups. In addition to using unique genes, analysis of the map positions of multicopy (homologous) genes identified syntenic homologs (characterized by similar positions on the maps) and pinpointed the positions of non-syntenic homologs. The comparison revealed extensive conservation of gene order between alfalfa and pea. However, genetic rearrangements (due to breakage and reunion) were localized which can account for the difference in chromosome number (8 for alfalfa and 7 for pea). Based on these genetic events and our increasing knowledge of the genomic structure of pea, it was concluded that the difference in genome size between the two species (the pea genome is 5- to 10-fold larger than that of alfalfa) is not a consequence of genome duplication in pea. The high degree of synteny observed between pea and Medicago loci makes further map-based cloning of pea genes based on the genome resources now available for M. truncatula a promising strategy.

Base Sequence↗

CT colonography practice in the UK: a national survey.

AIM: To determine the provision of computed tomography (CT) colonography in UK radiology departments. MATERIALS AND METHODS: A questionnaire relating to the availability of CT colonography, barriers to implementation, clinical indications, technique, and practitioners was posted to clinical directors of UK radiology departments. RESULTS: One hundred and thirty-eight departments responded. Fifty (36%) offered CT colonography in day-to-day clinical practice. Of those that did not, 68 of 87 (64%) cited limited scanner capacity as the main barrier. Of the 50 departments offering a service, 39 (78%) offered CT after incomplete colonoscopy, 36 (72%), after failed barium enema, and 37 (74%) as an alternative to barium enema. Of those offering a service, the number of studies performed varied between one per month (38%) to more than one per day (8%). Total experience varied between 20 or fewer studies (28%) to more than 300 (12%). Full bowel preparation was common (92%), as was dual positioning (90%). Colonography was interpreted by radiologists with a subspecialty interest in gastrointestinal imaging in 64% of centres offering a service. CONCLUSION: CT colonography is widely available in the UK, with approximately one-third of responders offering a service. Experience and throughput varies considerably. Limited CT scanner capacity is the major barrier to further dissemination.

Colonography, Computed Tomographic↗

Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study.

AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy.

Adenomatous Polyposis Coli↗

CT colonography: methods, pathology and pitfalls.

Computed tomography colonography (CTC) is a relatively new technique that is currently challenging more established methods of large bowel imaging. Several workers have suggested CTC surpasses the barium enema and approaches conventional endoscopy for detection of colorectal neoplasia. Accurate diagnosis relies on technically good studies, the main aim of which is adequate bowel cleansing and distension. Furthermore, the learning curve is steep and normal colonic anatomy has to be re-learned in a CT context. This review aims to describe the technique, revise the imaging features of both normal and pathological colon, and to highlight potential diagnostic pitfalls and their avoidance.

Colitis↗

Optimizing bowel preparation for multidetector row CT colonography: effect of Citramag and Picolax.

AIM: To compare the adequacy and acceptability of Picolax and Citramag bowel cleansing agents for CT colonography. MATERIALS AND METHODS: Multidetector row CT colonography was performed in 124 subjects; 43 had been prepared with Picolax and 81 with Citramag. Datasets were assessed for retained fluid and solid residue, and overall adequacy of segmental visualization. Preparation acceptability was also assessed. RESULTS: There was significantly less retained fluid with Picolax. The odds of being in the next higher category for retained fluid when using Picolax were 0.33 (CI: 0.22-0.50, p<0.0001) when compared with Citramag, for all segments combined. However there was significantly more retained solid residue with Picolax. The odds of being in the next higher category for retained residue when using Picolax were 2.44 (CI: 1.41-4.24, p=0.002) when compared with Citramag, for all segments combined. There was no significant difference with respect to overall segmental visualization: the odds of a segment being adequately visualized when using Picolax were 1.52 (CI: 0.88-2.65, p=0.14) when compared with Citramag. There was no significant difference with respect to acceptability. CONCLUSION: Picolax results in a significantly drier colon than Citramag and associated with more retained residue. We found Picolax the more suitable preparation for CT colonography.

Adenoma↗

Use of multidetector-row CT colonography for detection of colorectal neoplasia in patients referred via the Department of Health "2-Week-wait" initiative.

AIM: Patients referred under the Department of Health 2-week wait initiative with symptoms of colorectal cancer frequently undergo whole-colon examination. We investigated the use of computed tomography (CT) colonography as an alternative to colonoscopy in this scenario. MATERIALS AND METHODS: Fifty-four consecutive patients, referred via the 2-week wait initiative and scheduled for colonoscopy, consented to undergo multidetector CT colonography immediately before endoscopy. The site and morphology of any polyp or cancer detected by CT was noted and comparison made with subsequent colonoscopy. RESULTS: Colonoscopy detected polyps or cancer in 29 patients (53.7%). CT colonography prospectively detected 18 of 41 (44%) polyps of 1-5 mm, three of four (75%) polyps of 6-9 mm, four of four (100%) polyps 10 mm or larger, and five of six (83%) cancers. The missed cancer occurred early in the series and was a perceptive error. The overall sensitivity, specificity, positive predictive value and negative predictive value of CT colonography for cancer and polyps 10 mm or greater on a per patient basis were 90, 100, 100 and 98%, respectively. CT detected one renal cancer and one colonic cancer, initially missed due to incomplete colonoscopy. CONCLUSION: CT colonography is a robust technique for investigation of symptomatic patients. The learning curve must be overcome for optimal performance.

Adult↗

Phase II trial of CI-980 in patients with disseminated malignant melanoma and no prior chemotherapy. A Southwest Oncology Group study.

Malignant melanoma is increasing in frequency at a rapid rate in the United States. Metastatic disease is chemoresistant with DTIC considered the most active single agent. CI-980 is a synthetic mitotic inhibitor that blocks the assembly of tubulin and microtubules. It has shown cytotoxic activity against a broad spectrum of murine and human tumor cell tines. CI-980 can cross the blood brain barrier, is effective when given orally or parenterally, and is active against multidrug resistant cell lines overexpressing P-glycoprotein. In this trial, patients with disseminated melanoma with measurable disease, SWOG performance status of 0-1, no prior chemotherapy or immunotherapy for metastatic disease, and adequate hepatic and renal function, were enrolled. Treatment with CI-980 was given by 72 h continuous i.v. infusion at a dose of 4.5 mg/m2/day, days 1-3 every 21 days. Twenty-four patients were registered on this study with no patients ineligible. They ranged in age from 33-78 with performance status of 0 in 15 patients and 1 in 9 patients. Nineteen patients had visceral disease with 12 having liver involvement. There were no confirmed responses. The overall response rate was 0% (95% CI 0%-14%). The median overall survival is eleven months (95% CI 4-14 months). The most common toxicities were hematologic and consisted of leukopenia/granulocytopenia and anemia, with nausea/vomiting and malaise/fatigue/weakness also frequent. CI-980 administered at this dose and schedule has insufficient activity in the treatment of disseminated malignant melanoma to warrant further investigation.

Adult↗

Place identification and positive realities of aging.

The concepts of place attachment and place identity inform this study of the experiences of older African Americans in a small town in the midwestern United States. Life stories collected from ordinary people remembering the past fifty years offer a view of aging which is contrary to the widely reported negative status that stems from lifelong experiences of injustice and inequality. Individuals do not see themselves in such a state. Experiences relative to identification with and the attachment to a place hold powerful memories for older people. The cumulative memories of place allow individuals to maintain a favorable self-image in spite of the contingencies of later life. This affirms a positive rather than negative view of aging in a region people call 'God's Country'.

Journal Article↗

Physiological responses of the airway wall and lung in hyperresponsive pigs.

Airway hyperresponsiveness (AHR) might be driven by mechanisms inherent to the airway wall, and/or by factors arising from outside the airways. A porcine model of allergen-induced AHR was utilized to investigate physiological responses in intact airways in vitro and their contribution to responsiveness in vivo. Responsiveness to acetylcholine (ACh) was measured in eight ovalbumin (OA)-sensitized/challenged pigs (tests) and eight saline-challenged controls. In vivo responsiveness to ACh was determined from pulmonary resistance (RL). In vitro responsiveness to ACh was determined from airway pressure in isovolumic bronchial segments, after exposure via the adventitial or the luminal surface. Test pigs had lung (255+/-26% increase in RL, p<0.0001) and skin responses to OA, and AHR to ACh (p<0.0001). In vitro, test bronchi were less sensitive than controls to ACh applied to the airway adventitia (negative log of the ACh concentration producing half the maximum response (pD2)=4.18 and 4.58 respectively, p<0.01), but not the lumen. Test bronchi had an increased amount of smooth muscle normalized for airway size versus controls (p<0.05). Maximum responses to lumenal ACh in vitro showed a weak positive correlation with maximum changes to ACh in vivo (r=0.599, p=0.05). This study concludes that the effect of antigen challenge on bronchial responsiveness varies with the route of exposure to acetylcholine. In vitro responses to lumenal acetylcholine are increased despite a possible reduction in responsiveness of airway smooth muscle. Responsiveness of the bronchial wall only partially explains responsiveness of the lungs in vivo.

Acetylcholine↗