PubMed Health⌕ Search

Biomedical subjects

S A Turner

Publications and source records attributed to S A Turner.

At least 37 records · Page 2Linked to original sources

Development and evaluation of a long-term, implantable, electrically actuated left ventricular assist system: THI/Gould LVAS.

A long-term, implantable, electrically actuated left ventricular assist system (THI/Gould LVAS) is being developed and characterized in vitro and in vivo for utilization in patients with end-stage heart disease. This system consists of five major components: a long-term, implantable blood pump (THI E-type ALVAD); an electrical-mechanical energy converter (Gould Model V); a control unit with batteries; a volume compensation system; and an external power supply and monitoring unit. Two of these components (blood pump and electrical-mechanical energy converter) have been integrated, and are undergoing chronic in vivo evaluations in calves. Thus far, 44 pneumatically and electrically actuated THI/Gould LVAS evaluations have been performed. This experience has resulted in greater than 6.5 years of actuation in vivo, with durations exceeding 1 year. System in vivo performance in terms of durability, mechanical reliability, hemodynamic effectiveness, and biocompatibility has been satisfactory. Demonstration of long-term (2-year) effectiveness in supporting the circulation is the ultimate goal.

Animals↗

The feasibility and validity of orthodontic screening of children in their tenth year.

The study set out to investigate the problems of the implementation of the Court Report's suggestion that every child in its tenth year be screened for orthodontic treatment by "a dentist with special training in orthodontics' using Grainger's Treatment Priority Index (TPI). The study was divided into two parts. The standardization exercises used 31 orthodontic models of children in their tenth year. The problem of examiner variability, using a Community Dental Officer instead of an orthodontist and of bias that the TPI might have were examined. The main study involved the examination of 362 children in ten separate schools in Oxfordshire and investigated the problem of orthodontic screening at annual school inspections. The findings showed that the TPI may be able to provide a method for screening children in their tenth year if the weights of the clinical entities which are reducing the level of validity of the TPI are identified. The problem of scoring tooth displacements consistently would have to be taken into consideration when training personnel to use the TPI.

Child↗

Calcification in chronically-implanted blood pumps: experimental results and review of the literature.

Blood compatibility is a major objective in the development of long-term, implantable circulatory assist (left ventricular assist devices) and replacement (total artificial heart) devices. An important problem in experimental studies in animals has been the propensity for calcification to occur at the blood/material interface. Presented is a summary of our experience (27 studies) with blood pump calcification and a review of the current literature regarding this complication.

Journal Article↗

Development and evaluation of electrically actuated abdominal left ventricular assist systems for long-term use.

A long-term, totally implantable, electrically actuated, abdominally positioned left ventricular assist system (ALVAS) is being developed, characterized in vitro, and evaluated in vivo for utilization in patients with end-stage cardiac failure refractory to conventional therapeutic techniques. The first two major subsystems of the ALVAS (the pusher-plate blood pump and electrical-mechanical energy converters) have been integrated and are undergoing in vitro characterization and long-term in vivo evaluations in calves. Duration of these studies has exceeded 6 months. System performance in terms of hemodynamic effectiveness, mechanical reliability, and biocompatibility has been excellent and no untoward effects have been observed. Long-term effectiveness of the ALVAS remains to be established in continuing experiments, with a 2 year period of clinical use as an ultimate goal.

Abdomen↗

Combined use of dopamine and nitroprusside therapy in conjunction with intra-aortic balloon pumping for the treatment of postcardiotomy low-output syndrome.

Intra-aortic balloon pumping (IABP) has been utilized in our institution in over 600 patients for the treatment of postcardiotomy low-output syndrome, with a 59% survival rate. Volume loading and pharmacologic treatment have played integral roles in the overall treatment of this syndrome. This investigation documents the hemodynamic effectivenss of combined nitroprusside/dopamine therapy in patients who required IABP for weaning from cardiopulmonary bypass. Serial hemodynamic measurements were made before and during infusion of nitroprusside (0.5 to 5.0 microgram/kg/min) and after combined nitroprusside/dopamine (7.5 micrograms/kg/min) therapy in 10 patients during IABP. Prior to pharmacologic therapy, cardiac index was 1.6 +/- 0.4 L/min/m2 and systemic vascular resistance (SVR) was 2,774 +/- 932 dynes sec cm-5. After nitroprusside infusion, cardiac index increased to 1.8 +/- 0.5 L/min/m2 (NS) and SVR decreased to 1,957 +/- 791 dynes sec cm-5 (p less than 0.01). The simultaneous infusion of nitroprusside and dopamine resulted in further augmentation of cardiac index to 2.5 +/- 0.5 L/min/m2 (p less than 0.01) and an additional reduction of SVR to 1,439 +/- 358 dynes sec cm-5 (p less than 0.02). In addition, pressure-rate-product, an index of myocardial oxygen demand, was decreased by nitroprusside (p less than 0.02) but was not significantly altered by both agents. This study provides a rationale for the combined use of nitroprusside/dopamine in postcardiotomy low-output syndrome necessitating IABP when SVR is greater than 2,000 dynes sec cm-5 and cardiac index is less than 2.0 L/min/m2.

Assisted Circulation↗

Intraaortic balloon pumping women: effects of balloon size on survival.

Between 1972 and 1978, 429 patients underwent intraaortic balloon pump (IABP) counterpulsation in our institution. Ninety-six were women (22.4). The overall mortality was 52.9% for men and 69.8% for women. During 1978, however, the mortality for women decreased to 57.1%, even though they comprised a larger percentage of patients (28.2%) than before. The major indication for IABP support in these women was ischemic myocardial dysfunction resulting in failure to wean from cardiopulmonary bypass (THI hemodynamic Classification C) despite volume expansion and pharmacologic support. Improved results were obtained with the use of larger intraaortic balloons and direct ascending aortic IABP insertion (which allowed use of larger, more effective 30 or 40 ml balloons), combined with delayed sternal closure.

Adult↗

Persistent atrial paralysis: Case report with light microscopy and ultrastructural analyses.

Persistent atrial paralysis in a patient with complete heart block and mild mitral insufficiency is presented. Left atrial specimens obtained during implantation of a permanent cardiac pulse generator showed evidence of hypertrophy and fibrosis; subcellular degenerative changes ranged from near normal to irreversible, thus suggesting that atrial paralysis may be due to the replacement of normal atrial muscle with nonfunctional fibrous tissue.

Journal Article↗