PubMed Health⌕ Search

Biomedical subjects

S A Wickline

Publications and source records attributed to S A Wickline.

At least 19 recordsLinked to original sources

Occult cardiac contractile dysfunction in dystrophin-deficient children revealed by cardiac magnetic resonance strain imaging.

BACKGROUND: Duchenne muscular dystrophy (DMD) is an inherited disease characterized by early onset of skeletal muscle degeneration and progressive weakness. Although dilated cardiomyopathy may occur during adolescence, it is often undetected early in its course because of physical inactivity and generalized debilitation. The purpose of this study was to apply the technique of cardiac magnetic resonance (CMR) tagging to detect occult cardiac dysfunction in young subjects with DMD by measuring myocardial strain and torsion. METHODS AND RESULTS: Thirteen DMD pediatric subjects without clinically apparent heart disease and 9 age-matched healthy males were recruited. Each was scanned on a 1.5-T clinical scanner to acquire contiguous short-axis planes from the apex to the mitral valve plane and then 3 tagged images at base, midventricle, and apex. Global and segmental myocardial net twist and circumferential strain were computed with the use of 2D homogeneous strain analysis. Ventricular torsion was computed by normalizing net twist by the distance from apex to mitral valve plane. DMD patients exhibited normal left ventricular volumes and ejection fractions but manifested reduced midventricular and basal cross-sectional global circumferential strain compared with the reference group (P<0.005). These alterations also appeared in segmental analyses in the septal, anterior, lateral, and inferior walls (P<0.05). CONCLUSIONS: In patients predisposed to cardiomyopathies because of dystrophinopathy, occult regional cardiac dysfunction can be diagnosed with CMR tagging. This method of strain imaging analysis may offer a sensitive approach for delineating the presence and progression of cardiovascular disease and for assessing therapies designed to modulate the onset and course of heart failure.

Child↗

Novel MRI contrast agent for molecular imaging of fibrin: implications for detecting vulnerable plaques.

BACKGROUND: Molecular imaging of thrombus within fissures of vulnerable atherosclerotic plaques requires sensitive detection of a robust thrombus-specific contrast agent. In this study, we report the development and characterization of a novel ligand-targeted paramagnetic molecular imaging agent with high avidity for fibrin and the potential to sensitively detect active vulnerable plaques. METHODS AND RESULTS: The nanoparticles were formulated with 2.5 to 50 mol% Gd-DTPA-BOA, which corresponds to >50 000 Gd(3+) atoms/particle. Paramagnetic nanoparticles were characterized in vitro and evaluated in vivo. In contradistinction to traditional blood-pool agents, T1 relaxation rate as a function of paramagnetic nanoparticle number was increased monotonically with Gd-DTPA concentration from 0.18 mL. s(-1). pmol(-1) (10% Gd-DTPA nanoparticles) to 0.54 mL. s(-1). pmol(-1) for the 40 mol% Gd-DTPA formulations. Fibrin clots targeted in vitro with paramagnetic nanoparticles presented a highly detectable, homogeneous T1-weighted contrast enhancement that improved with increasing gadolinium level (0, 2.5, and 20 mol% Gd). Higher-resolution scans and scanning electron microscopy revealed that the nanoparticles were present as a thin layer over the clot surface. In vivo contrast enhancement under open-circulation conditions was assessed in dogs. The contrast-to-noise ratio between the targeted clot (20 mol% Gd-DTPA nanoparticles) and blood was approximately 118+/-21, and that between the targeted clot and the control clot was 131+/-37. CONCLUSIONS: These results suggest that molecular imaging of fibrin-targeted paramagnetic nanoparticles can provide sensitive detection and localization of fibrin and may allow early, direct identification of vulnerable plaques, leading to early therapeutic decisions.

Animals↗

Age-related alterations of cardiac tissue microstructure and material properties in Fischer 344 rats.

The cardiac aging process is accompanied by global mechanical dysfunction that reflects increased myocardial stiffness. Accordingly, age-related changes in microscopic material properties of myocardium were delineated with high-frequency ultrasound (US) (30 to 44 MHz) tissue characterization methods for aging Fischer 344 rats at 6 (adult), 18 (aged), and 24 (senescent) months of age. The excised lateral wall of the left ventricle of rats (n = 10 per group) was insonified with a 50-MHz acoustic microscope for determination of integrated backscatter, backscatter coefficient and attenuation coefficient. Histological and biochemical analyses for collagen content and cardiac myocyte diameter were performed. Collagen concentration increased progressively with age, with the greatest increments occurring from 6 to 18 months (38.0 +/- 6.3 to 53.0 +/- 7.1 mg/g dry wt), and leveling off at 24 months (60.0 +/- 7.4 mg/g dry wt). Tissue microscopic material properties also changed progressively from 6 to 24 months of age, as determined by US methods: integrated backscatter increased (-44.7 +/- 1.8 vs. -40.8 +/- 1.9 dB, p < 0.05), attenuation increased (47.1 +/- 5.9 to 65.3 +/- 7.8 dB/cm, p < 0.05), and the backscatter coefficient increased (0.73 +/- 0.16 x 10(-5) to 3.76 +/- 1.6 x 10(-5) cm(-1), p < 0.05), from 6 to 24 months of age in each case. Age-related alterations in indices of cardiac microscopic material properties were closely correlated with the changes in cardiac microstructure. Ultrasonic tissue characterization may prove to be a sensitive tool to monitor changes in the cardiac microstructure, such as increased collagen deposition, that occur within age-related diastolic dysfunction.

Aging↗

Echocardiographic characterization of fundamental mechanisms of abnormal diastolic filling in diabetic rats with a parameterized diastolic filling formalism.

Abnormalities of diastolic function (DF) precede systolic dysfunction in diabetic cardiomyopathy. Transmitral Doppler flow analysis is the primary method for noninvasively assessing DF. We used model-based Doppler E-wave analysis to evaluate diastolic function differences between normal and diabetic rat hearts. Control rats and those with diabetes underwent echocardiography with analysis by traditional Doppler indexes and by the parameterized diastolic filling (PDF) formalism, generating 3 parameters, x0, c, and k, that uniquely characterize each E-wave. Significant intergroup differences in the E/A ratios (P <.01), isovolumic relaxation times (P <.01), and the modeling parameter c (P <.05) were found. There were no significant differences in shortening fraction, deceleration time, myocardial collagen content, or the parameters x0 and k between diabetic and control rats. These results indicate that differences in diastolic function may be noninvasively quantified and that diabetic hearts may exhibit defects in uncoupling of the contractile apparatus without concomitant increases in chamber stiffness.

Animals↗

Temperature dependence of ultrasonic enhancement with a site-targeted contrast agent.

Molecular imaging contrast agents specifically detect the biochemical "signatures" of disease before anatomical manifestations are apparent. Sensitive and specific localization of fibrin both in vivo and in vitro has been demonstrated with the use of a ligand-directed liquid perfluorocarbon nanoparticle. Since the acoustic properties of perfluorocarbons are known to vary with temperature, it was hypothesized that temperature could be used to augment the magnitude of enhancement imparted by targeted nanoparticles. Accordingly, the acoustic backscatter of two different substrates, nitrocellulose membrane and human plasma clot, targeted by the nanoparticles was measured at temperatures ranging from 27 degrees to 47 degrees C in 5 degrees C increments. Classic avidin-biotin interactions were utilized to couple biotinylated nanoparticles to avidin-conjugated nitrocellulose membranes. Ultrasonic contrast enhancement of the nitrocellulose membrane at 25 MHz, measured by acoustic microscopy, increased from 2.0+/-0.3 dB at 27 degrees C to 3.7+/-0.4 at 47 degrees C. In a similar experiment, antifibrin nanoparticles bound to human plasma clots also exhibited temperature-dependent ultrasonic signal enhancement ranging from 13.9+/-1.5 dB at 27 degrees C to 18.1+/-1.5 dB at 47 degrees C. The increase in ultrasonic contrast enhancement measured was well described by a simple, acoustic transmission line model with temperature-dependent impedance. These results suggest that temperature-dependent changes in acoustic backscatter may be used to further differentiate tissues targeted with site-specific nanoparticles from surrounding normal soft tissues.

Acoustics↗

Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering method.

In many cardiac patients, image quality and/or scan efficiency is reduced due to imprecise R-wave ability to trigger the scan due to noise on the electrocardiogram (ECG) caused by the magnetic resonance (MR) environment. We developed a triggering system that uses the spatial information of the vectorcardiogram (VCG) to minimize the effects of MR-related noise on triggering. Fifteen volunteers underwent standard cardiovascular MR exams, and a total of 52,474 R-waves were evaluated with the algorithm, giving a performance index of 99.91%. The mean propagation delay of the system was -10.64 +/- 3.19 msec, which falls within the real-time definition for cardiac MRI triggering. Five patients had arrhythmias consisting of premature ventricular depolarizations (PVDs) and supraventricular extra systoles. For those patients with PVDs, all arrhythmic beats were rejected unless they passed through the algorithm's reference point. The performance index for the arrhythmic patients approached 100%. VCG-based triggering has been demonstrated to provide near 100% triggering performance during cardiac MR examinations.

Adult↗

Magnetic resonance contrast enhancement of neovasculature with alpha(v)beta(3)-targeted nanoparticles.

Site-directed contrast enhancement of angiogenic vessels in vivo was demonstrated using antibody targeting of an MRI contrast agent to the alpha(v)beta(3) integrin, a molecular marker characteristic of angiogenic endothelium. The agent was tested in a rabbit corneal micropocket model, in which neovasculature is induced in the cornea using basic fibroblast growth factor. The targeted contrast agent consists of Gd-perfluorocarbon nanoparticles linked to alpha(v)beta(3) integrin antibody DM101. The animal group receiving the targeted contrast agent displayed a 25% increase in the average MR signal intensity after 90 min. Control groups in which the nanoparticles are either used alone, linked to an isotype-matched antibody, or linked to DM101 and administered following receptor blocking did not display MR contrast enhancement at similar dose levels. These findings indicate that the antibody-targeted agent enhances MR signal intensity in the capillary bed in a corneal micropocket model of angiogenesis, and is selectively retained within the angiogenic region via specific interaction with the alpha(v)beta(3) epitope.

Animals↗

High-resolution MRI characterization of human thrombus using a novel fibrin-targeted paramagnetic nanoparticle contrast agent.

In this study, the sensitivity of a novel fibrin-targeted contrast agent for fibrin detection was defined in vitro on human thrombus. The contrast agent was a lipid-encapsulated perfluorocarbon nanoparticle with numerous Gd-DTPA complexes incorporated into the outer surface. After binding to fibrin clots, scanning electron microscopy of treated clots revealed dense accumulation of nanoparticles on the clot surfaces. Fibrin clots with sizes ranging from 0.5-7.0 mm were imaged at 4.7 T with or without treatment with the targeted contrast agent. Regardless of sizes, untreated clots were not detectable by T(1)-weighted MRI, while targeted contrast agent dramatically improved the detectability of all clots. Decreases in T(1) and T(2) relaxation times (20-40%) were measured relative to the surrounding media and the control clots. These results suggest the potential for sensitive and specific detection of microthrombi that form on the intimal surfaces of unstable atherosclerotic plaque.

Antibodies, Monoclonal↗

High-frequency ultrasound for quantitative characterization of myocardial edema.

Myocardial edema has been associated with impaired ventricular compliance and diastolic filling. To determine the sensitivity of high-frequency (40 MHz) ultrasound to myocardial edema, we employed a model in which myocardial edema was induced by immersion of tissue in isotonic saline. The effect of freezing tissue on edema formation was also evaluated. Rat hearts were arrested at end-diastole and insonified fresh within 15 min of excision (n = 5) or following being frozen for 24 h and thawed (n = 4). Measurements of attenuation, backscatter, tissue thickness and speed of sound were performed at baseline and hourly for 4 h, and compared with direct measurements of myocardial edema. Fresh tissue demonstrated a greater propensity for the development of edema than frozen tissue. Integrated backscatter increased in both tissues, whereas the magnitude and slope of attenuation decreased as edema evolved. We conclude that high-frequency ultrasound sensitively detects myocardial edema, and we propose that the extension of these methods to clinical frequencies may prove useful for monitoring and treatment of cardiac edematous disease states.

Acoustics↗

Delineation of the extracellular determinants of ultrasonic scattering from elastic arteries.

Elastic arteries consist of three primary components: elastin fibers, extracellular collagen matrix and smooth muscle cells. However, the relative contribution of elastin and collagen fibers to overall ultrasonic scattering from an intact arterial wall is poorly understood. To define the principal source of extracellular scattering from the medial layer of elastic arteries, canine ascending aortas (n = 10) were excised, fixed and sectioned for insonification. Subsequently, aortic specimens were restudied after treatment to dissolve all tissue components except extracellular collagen matrix (n = 5) and elastin fibers (n = 5). Histological staining revealed very few elastin fibers and sparse intact collagen in collagen-isolated and elastin-isolated tissues, respectively. Integrated backscatter, attenuation and backscatter coefficients differentiated these two treated tissues. The backscatter coefficient for elastin-isolated tissue demonstrated a fivefold increase over collagen-isolated tissue, suggesting that elastin fibers represent a primary scattering component within elastic arteries, and the collagen fibers may provide a secondary component of scattering.

Animals↗

In vivo molecular imaging of stretch-induced tissue factor in carotid arteries with ligand-targeted nanoparticles.

Molecular imaging permits tissues to be functionally characterized by identification of specific cell-surface receptors with targeted contrast agents. In our study, a ligand-targeted acoustic nanoparticle system was used to identify the angioplasty-induced expression of tissue factor by smooth muscle cells within the tunica media. Pig carotid arteries were overstretched bilaterally with balloon catheters, treated with a tissue factor-targeted or a control nanoparticle system, and imaged with intravascular ultrasound (20 MHz) before and after treatment. Carotid wall acoustic reflectivities were unaffected by overstretch injury. Tissue factor-targeted nanoemulsion bound and increased the echogenicity of smooth muscle cells expressing tissue factor within the tunica media. The targeted emulsion increased the arterial wall gray scale (99.4+/-14.5; P<.05) relative to pretreatment (41.8+/-11.1, P<0.05) and the control gray scale (pre-emulsion: 49.3+/-9.5; post-emulsion: 43.7+/-6.4; P<.05). The area of acoustic enhancement appeared to coincide with expression of induced tissue factor in the tunica media confirmed by immunohistochemistry. We have demonstrated that this novel nanoemulsion can infiltrate into arterial walls after balloon injury and localize the expression of overstretch-induced tissue factor within pig carotid arteries. Molecular imaging and quantification of complex, biochemical change, such as tissue factor expression after angioplasty, may prove to be a prognostically important predictor of subsequent restenosis.

Acoustics↗

Molecular imaging of stretch-induced tissue factor expression in carotid arteries with intravascular ultrasound.

RATIONALE AND OBJECTIVES: Molecular imaging with targeted contrast agents enables tissues to be distinguished by detecting specific cell-surface receptors. In the present study, a ligand-targeted acoustic nanoparticle system is used to identify angioplasty-induced expression of tissue factor by smooth muscle cells within carotid arteries. METHODS: Pig carotid arteries were overstretched with balloon catheters, treated with tissue factor-targeted or a control nanoparticle system, and imaged with intravascular ultrasound before and after treatment. RESULTS: Tissue factor-targeted emulsions bound and increased the echogenicity and gray-scale levels of overstretched smooth muscle cells within the tunica media, versus no change in contralateral control arteries. Expression of stretch-induced tissue factor in carotid artery media was confirmed by immunohistochemistry. CONCLUSIONS: The potential for abnormal thrombogenicity of balloon-injured arteries, as reflected by smooth muscle expression of tissue factor, was imaged using a novel, targeted, nanoparticulate ultrasonic contrast agent.

Animals↗

Left ventricular contractility is impaired following myocardial infarction in the pig and rat: assessment by the end systolic pressure-volume relation using a single-beat estimation technique and cine magnetic resonance imaging.

The end systolic pressure-volume relation (ESPVR) has been shown to be a relatively load independent measure of left ventricular (LV) contractility. Recently, several single-beat ESPVR computation methods have been developed, enabling the quantification of LV contractility without the need to alter vascular loading conditions on the heart. Using a single-beat ESPVR method, which has been validated previously in humans and assumes that normalized elastance is constant between individuals of a species, we studied the effects of myocardial infarction on LV contractility in two species, the rat and the pig. In our studies, LV pressure was acquired invasively and LV volume determined noninvasively with magnetic resonance imaging, at one week postinfarction in pigs and at 12 weeks postinfarction in rats. Normalized systolic elastance curves in both animal species were not statistically different from that of humans. Also, the slope of the ESPVR (Ees) decreased significantly following infarction in both species, while the volume-axis intercept (V0) was unaffected. These results indicate that a single-beat ESPVR method can be used to measure the inotropic response of the heart to myocardial infarction, and that the basis for this method (i.e., constant normalized elastance) is applicable to a variety of mammalian species.

Animals↗

Time evolution of enhanced ultrasonic reflection using a fibrin-targeted nanoparticulate contrast agent.

Complex molecular signaling heralds the early stages of pathologies such as angiogenesis, inflammation, unstable atherosclerotic plaques, and areas of remote thrombi. In previous studies, acoustic enhancement of blood clot morphology was demonstrated with the use of a nongaseous, fibrin-targeted acoustic nanoparticle emulsion delivered to areas of thrombosis both in vitro and in vivo. In this study, a system was designed and constructed that allows visualization of the evolution of acoustic contrast enhancement. To evaluate the system, two targets were examined: avidin-complexed nitrocellulose membrane and human plasma clots. The time evolution of enhancement was visualized in 10-min increments for 1 h. A monotonic increase was observed in ultrasonic reflection enhancement from specially treated nitrocellulose membranes for targeted emulsions containing perfluorooctylbromide (1.30+/-0.3 dB) and for perfluorooctane (2.64+/-0.5 dB) within the first 60 min of imaging. In comparison, the inherently nonechogenic plasma clots showed a substantial increase of 12.0+/-0.9 dB when targeted with a perfluoro-octane emulsion. This study demonstrates the concept of molecular imaging and provides the first quantifiable time-evolution report of the binding of a site-targeted ultrasonic contrast agent. Moreover, with the incorporation of specific drug treatments into the nanoparticulate contrast agent, ultrasonic molecular imaging may yield reliable detection and quantification of nascent pathologies and facilitate targeted drug therapy.

Contrast Media↗

The extracellular matrix is an important source of ultrasound backscatter from myocardium.

Ultrasound tissue characterization with measurement of backscatter has been employed in numerous experimental and clinical studies of cardiac pathology, yet the cellular components responsible for scattering from cardiac tissues have not been unequivocally identified. This laboratory has proposed a mathematical model for myocardial backscatter that postulates the fibrous extracellular matrix (ECM) as a significant determinant of backscatter. To demonstrate the importance of ECM, this group sought to determine whether measurements of backscatter from the isolated ECM could reproduce the known directional dependence, or anisotropy of backscatter, from intact cardiac tissues in vitro. Segments of left ventricular free wall from ten formalin fixed porcine hearts were insonified at 50 MHz, traversing the heart wall from endo- to epicardium to measure the anisotropy of myocardial backscatter, defined as the difference between peak (perpendicular to fibers) and trough (parallel to fibers) backscatter amplitude. The tissue segments were then treated with 10% NaOH to dissolve all of the cellular components, leaving only the intact ECM. Scanning electron micrographs (SEM) were obtained of tissue sections to reveal complete digestion of the cellular elements. The dimensions of the residual voids resulting from cell digestion were approximately the diameter of the intact myocytes (10-30 microm). These samples were reinsonified after seven days of treatment to compare the anisotropy of integrated backscatter. The magnitude of anisotropy of backscatter changed from 15.4 +/- 0.8 to 12.6 +/- 1.1dB for intact as compared with digested specimens. Because digestion of the myocardium leaves only extracellular sources of ultrasonic scattering, and because the isolated ECM exhibits similar ultrasonic anisotropy as does the intact myocardium, it is concluded that there is a direct association between the ECM and the anisotropy of backscatter within intact tissue. Thus, it is suggested that ultrasonic tissue characterization represents a potentially clinically applicable method for delineating the structure and function of the ECM.

Animals↗

Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse.

The ability of a blood pool contrast agent to enhance MR coronary angiography was defined. The proximal coronary vessels of pigs were imaged before and after administration of Gd-DTPA bound covalently to bovine serum albumin (0.2 mmol/ kg). The contrast agent resulted in a reduction of the blood T1 value to 33+/-5 msec, as determined in vivo with a Look-Locker technique. Both 2D and 3D imaging techniques were performed. An inversion pulse suppressed the signal of nonblood tissue postcontrast. After contrast agent administration, in the 3D data set the signal-to-noise ratio (SNR) of blood and contrast-to-noise ratio (CNR) of blood to myocardium were improved by factors of 2.0+/-0.2 and 15+/-8, respectively (P < 0.05). Postcontrast, the 3D acquisition was superior to the 2D technique in terms of spatial resolution, SNR of blood, and CNR of blood to myocardium. The high contrast of the 3D data set allowed for direct and rapid display of coronary arteries using a "closest vessel projection."

Animals↗