PubMed Health⌕ Search

Biomedical subjects

S Aburuz

Publications and source records attributed to S Aburuz.

6 recordsLinked to original sources

A cross-sectional study evaluating the relationship between cortisol suppression and asthma control in patients with difficult asthma.

AIM: To examine the relationship between cortisol suppression and asthma symptoms in patients with difficult asthma. METHODS: Patients, referred to a specialist difficult asthma service and who fulfilled the criteria for difficult asthma, were recruited to the study in a sequential, unselected manner. At each clinic visit, all patients completed a validated asthma control questionnaire. For measuring cortisol suppression, early morning urinary cortisol [corrected for creatinine to give urinary cortisol creatinine ratio (UCC ratio)] was used. The urine samples were collected and stored at -70 degrees C until ready for analysis. Urinary cortisol was extracted (solid-phase extraction) and analysed using high-performance liquid chromatography. The Pearson correlation coefficient was used for correlation analysis while t-tests were used for between-group differences for normally distributed data. If the data were not normally distributed, nonparametric statistics were used. A P-value < 0.05 was considered statistically significant. RESULTS: During the study period all the patients who attended the difficult asthma clinic and fulfilled the criteria for difficult asthma (n = 66) agreed to take part in the study. There were moderate to strong and significant associations between several measures of asthma control and UCC ratio. The correlation coefficient with five indicators of asthma control ranged between 0.3 and 0.5 (P < 0.05). CONCLUSIONS: We have demonstrated a relationship between cortisol suppression and asthma control in difficult asthmatics on high-dose steroid therapy. We have proposed a model based on the relationship between symptom control and cortisol suppression, whereby both adherence and therapeutic adjustments could potentially be made. A properly controlled prospective clinical trial should examine the utility of this approach in clinical practice.

Adult↗

An innovative pharmaceutical care practical course.

The innovative practical course was developed to improve the students' ability to acquire pharmaceutical care skills. The primary components of the course were in-school training using small group discussions and hospital experience including identification, analysis, prevention and resolution of drug-therapy problems, patient counseling on their medications and diseases, and interaction with medical team. Specific objectives of the research were to (1) compare students' performance before and after the course, (2) measure students' perceptions of their pharmaceutical care skills before and after the course, (3) determine students' perception of the value of the course. Statistical comparison of pre-test and post-test grades indicated both a retention and acquiring pharmaceutical care skills. A pre-course and post-course survey instrument was designed to measure students' perception of their pharmaceutical care skills. Perception of most of the items of the survey was significantly improved at the end of the course. Overall, the majority of students were highly satisfied with the course. In conclusion, the present study demonstrates that the innovative pharmaceutical care practical course was successfully introduced.

Clinical Competence↗

Simultaneous determination of sildenafil and N-desmethyl sildenafil in human plasma by high-performance liquid chromatography method using electrochemical detection with application to a pharmacokinetic study.

A method which employed high-performance liquid chromatography coupled with electrochemical detection was developed for the simultaneous determination of sildenafil and its metabolite, N-desmethyl sildenafil, in human plasma has. The method was developed and validated for purposes of its application to a pharmacokinetic study in healthy volunteers after an oral dose of 50mg/tablet under fasting conditions. High precision and accuracy were demonstrated. A one-step liquid-liquid extraction further provides a simple and practical way to process plasma samples containing sildenafil with good quantitative recovery. Sampling lasted for 24h after dosing; consequently a limit of quantitation (LOQ) of 7.858 ng/mL was achieved for sildenafil whereas a LOQ of 8.675 ng/mL was obtained for N-desmethyl sildenafil. The mobile phase consisted of acetonitrile, methanol and phosphate buffer (0.05 M) (18.5:34.5:47.0, v/v/v) pH 7.68. The stationary phase was a C(8) (150 mm x 4.6 mm), 5 microm particle size operated at 27 degrees C. All analytes were stable at the pH of the supernatant, and during the analytical time window. At the applied potential of +1.20 V versus Ag/AgCl, no interferences from endogenous plasma compounds were recorded at the retention times of sildenafil, N-desmethyl sildenafil. High resolution was obtained between the analytes and the employed internal standards.

Acetonitriles↗

Dried blood spot liquid chromatography assay for therapeutic drug monitoring of metformin.

The use of blood spot collection cards is a simple way to obtain specimens for analysis of drugs for the purpose of therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in routine clinical setting. We describe the development and validation of a microanalytical technique for the determination of metformin from dried blood spots. The method is based on reversed phase high-performance liquid chromatography with ultraviolet detection. Drug recovery in the developed method was found to be more than 84%. The limits of detection and quantification were calculated to be to be 90 and 150 ng/ml, respectively. The intraday and interday precision (measured by CV%) was always less than 9%. The accuracy (measured by relative error, %) was always less than 12%. Stability analysis showed that metformin is stable for at least 2 months when stored at -70 degrees C. The small volume of blood required (10 microL), combined with the simplicity of the analytical technique makes this a useful procedure for monitoring metformin concentrations in routine clinical settings. The method is currently being applied to the analysis of blood spots taken from diabetic patients to assess adherence to medications and relationship between metformin level and metabolic control of diabetes.

Drug Monitoring↗

The development and validation of liquid chromatography method for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma.

This article describes the development of SPE and HPLC methods for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Several extraction and HPLC methods have been described previously for the determination of each of these analytes in plasma separately. The simultaneous determination of these analytes is important for the routine monitoring of diabetic patients who take combination medications and for studying the pharmacokinetics of the combined dosage forms. In addition this developed method can serve as a standard method for the plasma determination of these analytes therefore saving time, effort and money. The recoveries of the developed methods were found to be between 76.3% and 101.9%. The limits of quantification were between 5 and 22.5 ng/ml. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error %) was always less than 12%. Stability analysis showed that all analytes are stable for at least 3 months when stored at -70 degrees C.

Chromatography, High Pressure Liquid↗

Relationship between lung function and asthma symptoms in patients with difficult to control asthma.

Several studies have demonstrated a poor relationship between measures of asthma control and lung function in patients with asthma. We sought to examine this relationship in a cohort of difficult to control asthmatics attending a hospital outpatient clinic. FEV1 % and asthma control scores (ACSs) were measured at the first clinic visit and at a follow-up visit. A total of 59 patients took part in the study. At the initial visit, FEV1 % correlated with limitation of activity (p = 0.002), shortness of breath (p = 0.02), wheezing (p = 0.029), and ACS (p = 0.014). However, at follow-up, there was no correlation between FEV1 % and any measured index of asthma control. When patients with severe fixed airflow obstruction were excluded from the analysis (n = 16), FEV1 % at follow-up became significantly correlated with night waking (p = 0.02), wheezing (p = 0.05), and ACS (p = 0.036). The improvement in asthma control score at follow-up was significantly and strongly associated (r = 0.51 for total asthma control, p < 0.001) with the improvement in lung function in patients without severe fixed airflow obstruction. Lung function was not associated with any measure of asthma control in patients with severe fixed airflow obstruction. FEV1 % correlates well with asthma symptoms in difficult asthma patients with poor control but not when control improves. This loss of relationship is due to subjects with severe fixed airflow obstruction where good subjective control does not exclude the presence of significant obstruction. How severe fixed airflow obstruction should be prevented, delayed, or managed in asthma requires further research.

Adult↗