PubMed Health⌕ Search

Biomedical subjects

S Achenbach

Publications and source records attributed to S Achenbach.

At least 19 recordsLinked to original sources

Atherosclerosis and vascular calcification in chronic renal failure.

Cardiovascular complications are a major clinical problem in patients with chronic kidney disease and end-stage renal failure; cardiac death accounts for approximately 40-50% of all deaths in these patients. Death from cardiovascular causes is up to 20 times more common in uremic patients than in the general population with the risk being even higher than in patients with diabetes mellitus. A high rate of myocardial infarction and excessive cardiac mortality have repeatedly been documented in patients with kidney disease and renal failure. Not only is the prevalence of myocardial infarction high, but also the case fatality rate is significantly higher in uremic patients with and without diabetes, respectively, compared to nonuremic patients. This is of particular interest since the prevalence of coronary atheroma in uremic patients was shown to be approximately 30% by autopsy and coronary angiography studies. Thus, coronary factors, i.e. atherosclerosis, and non-coronary factors may play an important role in the genesis of cardiac complications in the renal patient. In addition, renal failure recently has also be identified as a predictor of mortality in different stages of peripheral vascular disease. In particular, marked differences in the pathogenesis, morphology and course of atherosclerosis and arteriosclerosis under the conditions of renal failure have been documented. Among others increased plaque formation and particularly higher proportion and intensity of vascular calcification have been found in clinical and autopsy studies. In addition to the so-called classical or traditional risk factors, an important role for nonclassical risk factors such as microinflammation, hyperphosphatemia and oxidative stress has been documented in patients with renal failure and is discussed in detail.

Animals↗

Fetal transesophageal echocardiography: clinical introduction as a monitoring tool during cardiac intervention in a human fetus.

Because of insufficient imaging by maternal transabdominal fetal echocardiography (TAE) in a human fetus with aortic atresia, imperforate atrial septum and progressive cardiac failure, we assessed the feasibility of fetal transesophageal echocardiography (TEE) as a monitoring tool during fetal cardiac intervention at 24 + 6 weeks of gestation. Percutaneous fetoscopic intraesophageal deployment of the ultrasound catheter was achieved and did not result in any maternal or fetal complications. Fetal TEE permitted substantially clearer definition of fetal cardiac anatomy and intracardiac device manipulations than conventional maternal TAE. Despite the employment of various devices, no sufficiently large opening could be achieved within the atrial septum. Although the fetus tolerated the procedure remarkably well and satisfactory fetoplacental flow could be documented at the end of the procedure, the fetus died from progressive cardiac failure 3 days after the intervention. Fetoscopic TEE is feasible in the human fetus and permits substantially clearer definition of fetal cardiac anatomy and intracardiac manipulations than conventional maternal TAE. Based on the observation of spontaneous closure of multiple iatrogenic perforations of the atrial septum, specialized devices are required in order to improve the technical success rate of septoplasty methods and hence the survival odds of these high-risk patients.

Adult↗

Hepatitis B virus vaccination of blood donors--what costs may be expected?

Although the risk of transfusion-transmitted hepatitis B virus (TT-HBV) infection is very low, it still exists. Therefore, introduction of further precautions to reduce this risk is discussed at present. However, so far no data are available about the HBV vaccination status among blood donors (BDs). We compared HBV vaccination status of apheresis donors (ADs) of a university based and whole BDs (WBDs) of a Red Cross blood donation service using a standardized questionnaire. On the basis of these data, the estimated costs over 10 years for HBV vaccination were calculated for two different strategies and compared with the costs for HBV nucleic acid amplification technology (NAT) testing. 22.3% of the WBDs and 41.2% of the ADs indicated having received at least one HBV vaccine dose. This difference was related to the different demographic structures of the two BD populations (BDPs). With regard to the primary costs for the blood donation service, HBV vaccination of BDs could be an alternative to HBV NAT testing, especially for BDPs with an already high HBV vaccination rate and a high donation frequency.

Adult↗

Non-interventional cardiac diagnostics: computed tomography, magnetic resonance and real-time three-dimensional echocardiography. Techniques and clinical applications.

New cardiovascular imaging modalities, including computed tomography (CT), magnetic resonance (MR) imaging and real-time three-dimensional echocardiography, have great potential for providing important and additional information concerning cardiac function and pathology. With significant and extremely fast technical improvements, non-invasive cardiac imaging has become a focal point in the diagnosis of cardiac disease. Thereby CT has been shown to allow the visualization of coronary arteries concerning calcifications, significant stenoses and coronary plaques, whereas MR imaging demonstrated its ability to evaluate cardiac morphology and function as well as perfusion imaging and viability assessment. As CT and MR, real-time three-dimensional echocardiography has increasingly progressed in the last years offering the potential for routine clinical application, e.g. in the evaluation of valve disease, the assessment of left ventricular thrombi or the guidance of intracardiac catheter placement. This article will provide a brief overview of each technique, possible clinical applications and their perspectives. Because both, CT and MR, have been successfully applied to visualize the coronary arteries, this article focuses on the abilities and limitations of CT and MR coronary artery imaging.

Coronary Disease↗

Percutaneous fetoscopic tracheal balloon occlusion in sheep.

BACKGROUND: In order to minimize maternal trauma from current techniques for temporary fetoscopic tracheal occlusion, we tried to develop a percutaneous fetoscopic technique in sheep. METHODS: In nine ewes between 77 and 128 days of gestation, the amniotic cavity was entered percutaneously. Each fetus was positioned and the feasibility of fetal laryngoscopy and percutaneous fetoscopic tracheal balloon occlusion was assessed. RESULTS: Percutaneous intraamniotic access, fetal positioning, oropharyngeal sheath insertion, and fetoscopic laryngoscopy were achieved in all nine fetal sheep. Following some technical modifications to the working channel of the fetoscope, percutaneous fetoscopic tracheal balloon occlusion was successfully achieved in the last seven sheep. CONCLUSION: Percutaneous fetoscopic balloon occlusion of the fetal trachea can effectively and safely be achieved in sheep. Because intraamniotic spatial relationships, fetal position, and umbilical cord length are technically less favorable in sheep, our operative techniques might be feasible in humans even if difficult intraamniotic conditions are encountered.

Animals↗

Percutaneous fetoscopic patch coverage of experimental lumbosacral full-thickness skin lesions in sheep.

BACKGROUND: In order to minimize maternal trauma from open fetal surgery for prenatal coverage of fetal myelomeningoceles in humans, we assessed the feasibility of a percutaneous fetoscopic approach in sheep. METHODS: In seven ewes between 90 and 100 days of gestation, the amniotic cavity was entered percutaneously. Each fetus was postured and a full-thickness skin lesion was created in the lumbosacral region. Then, the feasibility of covering this lesion with a patch and fetal skin by standard endoscopic suturing techniques (n = 3) or robot assistance (n = 4) was assessed. RESULTS: Percutaneous fetoscopic patch and skin coverage of the full-thickness skin lesion was achieved in six of the seven fetal sheep. Five fetuses survived gestation and were delivered healthy. CONCLUSIONS: Percutaneous fetoscopic posturing and patch coverage of lumbosacral full-thickness skin lesions can effectively and safely be achieved in sheep. This approach promises to provide a substantial reduction of maternal trauma from fetal surgery for myelomeningoceles.

Animals↗

[Detection of coronary calcifications by electron beam tomography and multislice spiral CT: clinical relevance].

Coronary calcifications can be detected and quantified using electron beam tomography (EBT) or newer generation multi-slice spiral CT (MSCT) scanners. An abundance of data has been acquired by EBT. It could be shown that the amount of coronary calcium correlates to the coronary plaque burden. The detection of coronary calcium with CT imaging methods therefore provides a unique opportunity to detect and quantify coronary atherosclerosis in a subclinical stage. Consequently, the presence and amount of coronary calcium has been shown to be indicative for an increased coronary event risk in symptomatic and asymptomatic individuals. Several clinical studies found a predictive value that was superior to conventional risk factors. Clinically, the use of coronary calcification assessment may therefore be beneficial in patients who, based on traditional risk factors, seem to be at "intermediate risk" for coronary events (10-year event risk 10-20%) in order to decide on the aggressiveness of risk factor modification. The role of coronary calcium quantification to monitor the progression of disease has not been clarified yet. Large, ongoing trials will provide further data as to the relative merit of coronary calcium assessment for risk stratification and will help to more clearly define its clinical role. The relationship between coronary calcium and coronary stenoses is more complex. While the absence of coronary calcifications makes significant coronary stenoses unlikely, even large amounts of coronary calcium do not necessarily indicate the presence of coronary artery stenoses. Pronounced coronary calcifications as an isolated finding should therefore not be the motivation for invasive diagnostic procedures in the absence of other evidence of ischemic heart disease.

Calcinosis↗

Factors associated with coronary artery calcification in young female patients with SLE.

BACKGROUND: With improved survival rates of patients with systemic lupus erythematosus (SLE), damage such as accelerated atherosclerosis gains increasing importance. OBJECTIVE: To identify the prevalence of coronary artery calcifications (CAC) in asymptomatic patients. METHODS: Electron beam tomography (EBT) was performed in 75 female patients with SLE aged <50. The results were correlated with traditional and SLE related factors associated with CAC. 49 women with symptomatic coronary heart disease (CHD) and 279 women without CHD were also analysed. RESULTS: Overall, 21/75 (28%) patients had CAC. Low HDL cholesterol levels <1.40 mmol/l (p=0.03, OR=1.8, 67% v 39%) and cigarette smoking (p=0.01, OR=5.7, 76% v 44%) were identified as factors associated with CAC. Hypertension and high cholesterol were more common in women with CHD (p<0.01) than in those without CHD. SLE related factors were proteinuria (1331 v 465 mg/day, p=0.02), impaired renal function (p=0.02, OR=2.6, 26% v 6%), and high C3 levels (p=0.04, OR=1.8, 65% v 38%). High C3 levels were also more common in symptomatic CHD (p=0.02). The prevalence of Sm antibodies was lower in patients with CAC (15% v 42%, p=0.03). In a multivariate analysis, cigarette smoking, reduced renal function, high C3, and a cumulative steroid dose above 30 g were the most important CAC associated factors in the lupus cohort. CONCLUSION: A subgroup of patients with SLE with CAC without any clinical symptoms of CHD was identified by EBT. Therefore, EBT is useful for assessing asymptomatic atherosclerosis in this group.

Adult↗

Coronary calcifications in young patients with first, unheralded myocardial infarction: a risk factor matched analysis by electron beam tomography.

OBJECTIVE: To compare the presence and extent of coronary calcifications in young patients with first, unheralded acute myocardial infarction with matched controls without a history of coronary artery disease. METHODS: In 102 patients under 60 years of age (19-59 years, mean 41 years; 88% male), electron beam tomography was done 1-14 days after acute myocardial infarction, before any coronary intervention. Coronary calcifications were quantified using the Agatston score. Age related calcium centiles were determined based on the Mayo Clinic "epidemiology of coronary calcification" study, and results were compared with a group of 102 controls without coronary artery disease, matched for sex, age, and risk factors. RESULTS: Calcifications were present in 95.1% of patients with acute myocardial infarction and in 59.1% of controls (p = 0.008). The mean (SD) Agatston score was 529 (901) in the infarct patients versus 119 (213) in the controls (p < 0.001). An Agatston score above the 50th centile was present in 87.2% of infarct patients and 47.0% of controls (p = 0.006), and above the 90th centile in 60.7% of infarct patients and only 5.8% of controls (p = 0.001). CONCLUSIONS: In young patients with their first, unheralded acute myocardial infarction, the presence and extent of coronary calcium are significantly greater than in matched controls.

Adult↗

[Influence of heart rate on image quality and detection of coronary stenoses with multislice spiral CT].

Multi-slice spiral CT (MSCT) permits the detection of coronary stenoses. We investigated the influence of the patient's heart rate (HR) during the scan on stenosis detection and the presence of motion artifacts. In 100 patients MSCT was performed and retrospectively ECG-gated cross-sectional images were reconstructed. 115 of 400 coronary arteries (29%) were unevaluable due to motion artifacts (84/115) or other reasons (31/115). In evaluable arteries, sensitivity was 91% (51/56 high grade stenoses detected), specificity was 89%. With increasing HR, the number of unevaluable arteries increased and overall sensitivity for stenosis detection decreased from 62% (HR < or = 70 bpm) to 33% (HR > 70 bpm). MSCT permits detection of coronary stenoses, but evaluability and accuracy decrease with increasing HR.

Aged↗

Progression of aortic valve calcification: association with coronary atherosclerosis and cardiovascular risk factors.

BACKGROUND: Recent studies demonstrated an influence of atherosclerotic risk factors on the progression of aortic valve stenosis. The extent of aortic valve calcification (AVC) was also found to be a strong predictor of stenosis progression. We investigated the influence of the LDL cholesterol level (LDL), other standard cardiovascular risk factors, and the extent of coronary calcification (CC) on the progression of AVC quantified by electron beam tomography (EBT). METHODS AND RESULTS: In 104 patients (64.7+/-8 years, 89 male) with an EBT scan positive for AVC, CC and AVC were quantified using a volumetric score. EBT was repeated at a mean interval of 15 months (10 to 36 months), and the progression of AVC and CC was determined. Patients were divided into 2 groups according to LDL: group 1, LDL</=3.36 mmol/L (130 mg/dL), 57 patients; group 2, LDL>3.36 mmol/L (130 mg/dL), 47 patients. Mean values for CC were 546+/-932 mm(3) in scan 1 and 665+/-1085 mm(3) in scan 2 for AVC 324+/-796 mm(3) and 404+/-1076 mm(3), respectively. The mean progression of CC was 27+/-37% (group 1, 16+/-22%; group 2, 39+/-46%, P</=0.001) and of AVC was 25+/-38% (group 1, 9+/-22%; group 2, 43+/-44%, P</=0.001). CONCLUSIONS: Quantification of AVC by EBT permits new insights into the progression of aortic valve sclerosis. We observed a strong influence of LDL cholesterol level on the progression of AVC and CC, suggesting that lipid-lowering therapy may decrease the progression of aortic valve calcification.

Aged↗

Multimodal fetal transesophageal echocardiography for fetal cardiac intervention in sheep.

BACKGROUND: The overall performance of available mechanical intravascular ultrasound catheters for fetal transesophageal echocardiography during fetoscopic fetal cardiac interventions in sheep has been limited by radioelectronic interference, low system frame rates, and low acoustic outputs. Therefore, a more reliable device is desired for human fetoscopic surgical procedures. METHODS AND RESULTS: We assessed the potential of a newly available 10-French phased-array intravascular ultrasound catheter for multimodal fetal transesophageal echocardiography in 5 fetal sheep between 78 and 98 days of gestation (term, 145 to 150 d). The intravascular ultrasound catheter was easily inserted through the mouth into the esophagus in all 5 sheep fetuses (mean weight, 600 g), and it permitted high-quality 2D imaging of the fetal heart in vertical imaging planes that were validated by MRI. Color Doppler and pulsed Doppler imaging permitted clear assessment of fetal cardiovascular flows and recording of velocity-time integral tracings of the fetal heart and great vessels. The vertical imaging planes were particularly useful to demonstrate interventional material inside the fetal heart and great vessels. CONCLUSIONS: Our early experience with the phased-array intravascular ultrasound catheter indicates that multimodal fetal transesophageal echocardiography has now become possible in these smallest of patients.

Animals↗

Noninvasive coronary angiography by magnetic resonance imaging, electron-beam computed tomography, and multislice computed tomography.

In recent years, several techniques for noninvasive imaging of the coronary artery lumen (noninvasive coronary angiography) have been developed. These techniques include magnetic resonance imaging, electron-beam computed tomography, and, most recently, multislice computed tomography. Each of these techniques has specific advantages and disadvantages. Currently, EBCT seems to permit the most robust coronary artery imaging. In the future, imaging modalities will have to be further improved and validated in order to define specific areas for potential clinical applications.

Clinical Trials as Topic↗