[Pacing mode influence on morbidity and mortality].

It is widely believed that physiologic pacing (defined as atrial or atrioventricular synchronous pacing) reduces cardiac morbidity and mortality and is associated with improved quality of life compared to ventricular pacing. In this review we present data from three large prospective trials (PASE, CTOPP, MOST) comparing physiologic pacing to ventricular pacing. The prospective trials report that physiologic pacing is associated with a reduced risk of developing chronic atrial fibrillation over time and improved quality of life in patients with sinus node disease compared to ventricular pacing. However, these trials failed to demonstrate that physiologic pacing reduces heart failure, thromboembolism, or cardiac death compared to ventricular pacing. Based on the available clinical trials, physiologic pacing is not indicated in patients with a short life expectancy. Physiologic pacing should be considered for younger patients (age < 75 years), patients likely to be pacemaker dependent, and patients for whom maintenance of sinus rhythm is desirable, i.e., patients with ventricular hypertrophy and diastolic dysfunction who are most likely to be severely symptomatic if AV synchrony is lost.

Humans↗

Single pass lead VDD pacing in children and adolescents.

Implantation of permanent pacemakers in children and adolescents is possible but usually is limited to single chamber generators. The natural growth of these patients may require physiological pacing, but until recently two leads were required for this type of pacing. The single pass lead VDD pacing mode makes possible physiological pacing by using only one lead, for both atrial sensing and ventricular sensing and pacing. The feasibility of VDD pacing using endocardial lead was evaluated in 16 children and adolescents with congenital or postsurgical atrioventricular block. Their mean age was 7.9 +/- 4.9 years (range 1-16 years) and the smallest patient's weight was 8.2 kg. In all the patients, a single pass pacing lead with atrial sensing rings and bipolar ventricular pacing and sensing capability was implanted through the left or right subclavian vein. The pacemaker generator was implanted in a rectopectoral position. The mean atrial electrogram during the implantation was 4.2 +/- 2.1 mV and 2.6 +/- 1.9 mV after a mean of 1 week. The ventricular pacing threshold was 0.5 +/- 0.2 V; the ventricular pacing impedance was 560 +/- 95 omega; and the ventricular electrogram amplitude was 9.9 +/- 2.1 mV. This is a first report to demonstrate the feasibility of atrial synchronous ventricular endocardial pacing using a single pass lead in a relatively large group of children and adolescents.

Adolescent↗

The management of soft tissue complications related to pacemaker implantations.

During the last six years (1988-1993) we have treated 15 patients suffering from soft tissue problems related to pacemaker implantations which included: skin erosions (2 patients), impending extrusion of the pacemaker pulse generator due to capsular contracture (4 patients), exposed pacemaker generator (6 patients), and exposed electrode (3 patients). This article describes a conservative approach to the treatment of these complications. Skin erosions are treated topically with antibacterial creams or solutions. Local infection is controlled by the administration of systemic antibiotics according to the antibiogram, as well as with local antibacterial dressings. Impending extrusion or exposure of the pacing system are treated by subcapsular relocation of the pacemaker generator or vertical-to-horizontal transposition of the exteriorized lead. These restricted local surgical interventions are designed to overcome the vertical force which tends to cause the extrusion of pacing hardware without using another implantation site which are already limited in number. This approach, which can be repeated, prevents the reintroduction of a new pacing system. The pre-operative evaluation, surgical techniques and a long term follow-up are presented.

Anti-Bacterial Agents↗

The management of exposed cardiac pacemaker pulse generator and electrode using restricted local surgical interventions; subcapsular relocation and vertical-to-horizontal bow transposition techniques.

This paper describes an approach to the treatment of exposed pacemaker generator and electrode. Local infection is controlled by the administration of systemic antibiotics and topical antibacterial solutions. Because the generator and lead are enveloped by an inert synthetic coating, it is possible to eradicate an infection without their removal if it is due to a weak opportunist pathogen fully sensitive to antibiotics. Thereafter, subcapsular relocation of the exposed generator or vertical-to-horizontal transposition of the exteriorised lead is carried out. These surgical interventions are designed to overcome the vertical force which tends to cause the extrusion of the pacing hardware.

Aged↗

Pacemaker implantation in a patient with a Behçet's disease associated with superior vena cava obstruction.

A 65-year-old man with Behçet's disease developed transient complete A-V block with syncope. An attempt to implant a permanent transvenous endocardial electrode failed owing to obstructions in the subclavian, innominate, and superior vena cava veins demonstrated by angiography. Sutureless epicardial electrodes were successfully implanted through a subxyphoid approach. Obstruction in the great veins is a common feature in patients with Behçet's disease. We suggest that patients with this disorder, who require a permanent pacemaker, should be investigated by angiography prior to implant to rule out obstruction in the upper great veins.

Aged↗

Discrimination of antegrade and retrograde atrial depolarization by electrogram analysis.

The inability of cardiac pacemakers to selectively reject retrograde P waves limits the usefulness of dual-chamber pacemakers (because of the possibility of endless loop tachycardias) and of antitachycardia devices which use a dual-chamber sensing algorithm. In order to determine selective sensing parameters, amplitude, slew rate, and configuration of antegrade and retrograde atrial electrograms were measured in 34 patients undergoing dual-chamber pacemaker implant--31 with unipolar and three with bipolar units. All antegrade and retrograde pairs were measurably different. All 34 cases had measurable antegrade/retrograde amplitude differences; 30 of the unipolar cases (96.8%) and all bipolar cases displayed antegrade/retrograde amplitude differences of at least 0.25 mV. Thirty of the unipolar cases (96.8%) and two bipolar cases had measurable slew rate differences. Configuration differed in 14 of 31 (45.2%) of unipolar and in two bipolar cases. A combined criterion with 0.25 mV sensitivity steps (available in at least two presently available pacemakers) and 0.5 V/sec slew rate gradations (through the use of externally programmable filters) would allow the discrimination of retrograde from antegrade depolarizations in all 34 cases. With the use of amplitude and slew rate differences, it is therefore possible to reject retrograde P waves while sensing antegrade P waves with current technology.

Cardiac Pacing, Artificial↗

"Pseudo-endless loop" tachycardia in an AV universal (DDD) pacemaker.

A 3-beat episode of ventricular arrhythmia was recorded in a patient with an AV universal (DDD) pacemaker. This arrhythmia mimicked "endless loop" tachycardia (ELT) because it appeared following a ventricular premature contraction (VPC), its rate approached the preset upper-rate limit and the regular P waves disappeared during the episode. However, as retrograde conduction was absent ELT could not exist. The mechanism of this arrhythmia was based on a combination of interference by VPC of the regular sequence of QRS complexes produced by P wave and the pacemaker commitment to maintain an upper rate limit by prolongation of the programmed pacemaker AV delay.

Electrocardiography↗

Programmed upper-rate limit dependent endless loop tachycardia.

In a patient with a VDD dual chamber pacemaker, an endless loop tachycardia (ELT) appeared spontaneously or could be provoked by magnet application and removal. The duration of the ELT was dependent on the programmed upper-rate limit of the pacemaker, ie, the higher it was set, the shorter the duration of the ELT. This was caused by the automatic variable pacemaker AV delay (the Wenckebach effect) which prolongs maintaining the programmed cycle length at each upper-rate limit during the tachycardia. This case illustrates the mechanism by which increasing the upper-rate setting of this unit prevents or restrains the ELT.

Aged↗

Maternal permanent bradycardia: pregnancy and delivery.

Presented are six women with permanent bradycardia without myocardial involvement. Four women were asymptomatic, and two had repeated Adams-Stokes attacks and required the use of permanent pacemakers. All six women had 18 pregnancies with 15 deliveries of normal infants. During pregnancy and delivery all patients remained asymptomatic (functional capacity 1). The various cardiologic and obstetric aspects of these patients are discussed, and it is concluded that pregnancy and delivery in women with permanent bradycardia is possible, and their outcome is no different from that of normal, healthy women. However, cases with associated myocardial disease carry an increased risk and should therefore be carefully monitored during pregnancy and delivery.

Adult↗

Atrial lead malposition in a dual chamber (DDD,M) pacemaker.

A model 7000 pacemaker in the DVI mode emitted two stimuli, the first stimulating the right ventricle and the second 110 ms later. The atrial lead was found in the right ventricular outflow tract. The QRS complex produced by the atrial lead fell after the blanking period, and "committed" the ventricular stimulus 110 ms after the "atrial." Intracardiac electrography during the original implant would have enabled proper atrial lead position.

Aged↗

Complete heart block in an adult with corrected transposition of the great arteries treated with permanent pacemaker.

A 53-year-old patient with corrected transposition of the great arteries developed complete heart block with fainting episodes. After temporary pacing through the endocardium of the venous (anatomically left) ventricle, a permanent epicardial pacemaker was implanted. This case shows the progressive nature of the atrioventricular conduction disturbances, which are very common in association with this congenital cardiac anomaly.