PubMed Health⌕ Search

Biomedical subjects

S Attiya

Publications and source records attributed to S Attiya.

4 recordsLinked to original sources

Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay.

A six-channel microfluidic immunoassay device with a scanned fluorescence detection system is described. Six independent mixing, reaction, and separation manifolds are integrated within one microfluidic wafer, along with two optical alignment channels. The manifolds are operated simultaneously and data are acquired using a singlepoint fluorescence detector with a galvano-scanner to step between separation channels. A detection limit of 30 pM was obtained for fluorescein with the scanning detector, using a 7.1-Hz sampling rate for each of the reaction manifolds and alignment channels (57-Hz overall sampling rate). Simultaneous direct immunoassays for ovalbumin and for anti-estradiol were performed within the microfluidic device. Mixing, reaction, and separation could be performed within 60 s in all cases and within 30 s under optimized conditions. Simultaneous calibration and analysis could be performed with calibrant in several manifolds and sample in the other manifolds, allowing a complete immunoassay to be run within 30 s. Careful chip conditioning with methanol, water, and 0.1 M NaOH resulted in peak height RSD values of 3-8% (N = 5 or 6), allowing for cross-channel calibration. The limit of detection (LOD) for an anti-estradial assay obtained in any single channel was 4.3 nM. The LOD for the cross-channel calibration was 6.4 nM. Factors influencing chip and detection system design and performance are discussed in detail.

Journal Article↗

Design of an interface to allow microfluidic electrophoresis chips to drink from the fire hose of the external environment.

An interface design is presented that facilitates automated sample introduction into an electrokinetic microchip, without perturbing the liquids within the microfluidic device. The design utilizes an interface flow channel with a volume flow resistance that is 0.54-4.1 x 10(6) times lower than the volume flow resistance of the electrokinetic fluid manifold used for mixing, reaction, separation, and analysis. A channel, 300 microm deep, 1 mm wide and 15-20 mm long, was etched in glass substrates to create the sample introduction channel (SIC) for a manifold of electrokinetic flow channels in the range of 10-13 microm depth and 36-275 microm width. Volume flow rates of up to 1 mL/min were pumped through the SIC without perturbing the solutions within the electrokinetic channel manifold. Calculations support this observation, suggesting a leakage flow to electroosmotic flow ratio of 0.1:1% in the electrokinetic channels, arising from 66-700 microL/min pressure-driven flow rates in the SIC. Peak heights for capillary electrophoresis separations in the electrokinetic flow manifold showed no dependence on whether the SIC pump was on or off. On-chip mixing, reaction and separation of anti-ovalbumin and ovalbumin could be performed with good quantitative results, independent of the SIC pump operation. Reproducibility of injection performance, estimated from peak height variations, ranged from 1.5-4%, depending upon the device design and the sample composition.

Animals↗

Integrated system for high-throughput protein identification using a microfabricated device coupled to capillary electrophoresis/nanoelectrospray mass spectrometry.

An integrated microsystem providing rapid analyses of trace-level tryptic digests for proteomics application is presented. This modular microsystem includes an autosampler and a microfabricated device comprising a sample introduction port and an array of separation channels together with a low dead-volume facilitating the interface to nanoelectrospray mass spectrometry. Sequential injection and separation of peptide standards and tryptic digests was achieved with a throughput of up to 30 samples per hour with less than 3% sample carryover. Replicate injections of peptide mixtures indicated that reproducibility of migration time was typically better than 2.3% relative standard deviation (RSD) whereas RSD values of 3.7-11.8% were observed on peak height. Mass spectral detection of submicromolar protein digests (< 7 femtomoles/injection) was achieved using a quadrupole/time of flight instrument in less than 2 min/per sample with peak widths of 1.8-7.0 s. The analytical potential of this integrated device for the identification of gel isolated proteins from Neisseria meningitidis immunotype L3 has been demonstrated using both peptide mass-fingerprint database searching and on-line tandem mass spectrometry.

Amino Acid Sequence↗

Red diode laser induced fluorescence detection with a confocal microscope on a microchip for capillary electrophoresis.

A highly sensitive laser induced fluorescence (LIF) detection system based on a 635 nm laser diode and cyanine-5 (Cy-5) dye, is described for use with a planar, microfluidic, capillary electrophoresis (CE) chip. The CE-chip is able to determine a protein biological threat agent simulant, ovalbumin (Ov), by performing an immunoassay separation of Cy-5 labeled anti-ovalbumin from its complex with Ov, in under 30 s. A confocal, epiluminescent detection system utilizing a photomultiplier tube gave optimum results with a 400 microm pinhole, an Omega 682DF22 emission filter, a 645DRLP02 dichroic mirror, a 634.54 +/- 5 nm excitation filter, and a Power Technology ACMO8 635 nm laser operated at 11.2 mW. Using this detector, a microchip CE device with a separation efficiency of 42,000 plates and an etch depth of 20 microm, gave a concentration detection limit of 9 pM Cy-5. This limit corresponds to the determination of 4560 injected molecules and detection of 900 of these molecules, given a probe volume of 1.6 pl and a probing efficiency of 20%.

Electrophoresis, Capillary↗