PubMed Health⌕ Search

Biomedical subjects

S B Hansen

Publications and source records attributed to S B Hansen.

At least 19 recordsLinked to original sources

Temperature determination using Kalpha spectra from M -shell Ti ions.

The compact multipulse terawatt (COMET) laser facility at LLNL was used to irradiate Al-coated 2-50 microm Ti foils with approximately 10(19) W cm(-2) , 500 fs, 3-6 J laser pulses. Laser-plasma interactions on the front side of the target generate hot electrons with sufficient energy to excite inner-shell electrons in Ti, creating Kalpha emission which has been measured using a focusing spectrometer with spatial resolution aimed at the back surface of the targets. The spatial extent of the emission varies with target thickness. The high spectral resolution (lambda/Deltalambda approximately equal to 3800) is sufficient to measure broadening of the Kalpha emission feature due to the emergence of blueshifted satellites from ionized Ti in a heated region of the target. A self-consistent-field model is used to spectroscopically diagnose thermal electron temperatures up to 40 eV in the strongly coupled Ti plasmas.

Journal Article↗

Measurement of 2l-nl' x-ray transitions from approximately 1 microm Kr clusters irradiated by high-intensity femtosecond laser pulses.

X-ray line emission from 2l-nl' transitions in Ne-like Kr and nearby ions has been observed from approximately 1 microm Kr clusters irradiated by fs-scale laser pulses at the JAERI facility in Kyoto, Japan. The incident laser intensity reached 10(19) W/cm2, with pulse energies from 50 to 300 mJ and pulse durations from 30 to 500 fs. The dependence of the x-ray spectral features and intensity on the incident laser intensity is rather weak, indicating that the 1-2 ps cluster lifetimes limit the number of ions beyond Ne-like Kr that can be produced by collisional ionization. Lines from F- to Al-like Kr emitted from the cluster plasmas have been identified using data from the relativistic multiconfiguration flexible atomic code. A collisional-radiative model based on these data has been constructed and used to determine that the cluster plasma has electron densities near 10(22) cm(-3), temperatures of a few hundred eV, and hot electron fractions of a few percent.

Journal Article↗

Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior.

Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabilizing effect of using two different prior functions as well as image representation by blobs so that the number of iterations could be increased without noise build-up. Reconstruction was performed of simulated phantoms and of real data acquired by positron emission tomography. Image quality measures were calculated for images reconstructed with or without priors. Both priors stabilized the iteration process. The first prior based on the Huber function reduced the noise without significant loss of contrast recovery of small spots, but the drawback of the method was the difficulty in finding optimal values of two free parameters. The second method based on a median root prior has only one Bayesian parameter which was easy to set, but it should be taken into account that the image resolution while using that prior has to be chosen sufficiently high not to cause the complete removal of small spots. In conclusion, the Huber penalty function gives accurate and low noise images, but it may be difficult to determine the parameters. The median root prior method is not quite as accurate but may be used if image resolution is increased.

Algorithms↗

Effects of the electron energy distribution function on modeled x-ray spectra.

This paper presents the results of a broad investigation into the effects of the electron energy distribution function on the predictions of nonlocal thermodynamic equilibrium collisional-radiative atomic kinetics models. The effects of non-Maxwellian and suprathermal ("hot") electron distributions on collisional rates (including three-body recombination) are studied. It is shown that most collisional rates are fairly insensitive to the functional form and the characteristic (central or average) energy of the electron distribution function as long as the characteristic energy is larger than the threshold energy for the collisional process. Collisional excitation and ionization rates are, however, highly sensitive to the number of hot electrons. This permits the development of robust spectroscopic diagnostics that can be used to characterize the electron density, bulk electron temperature, and hot electron fraction of plasmas with nonequilibrium electron distribution functions. Hot electrons are shown to increase and spread out plasma charge state distributions, amplify the intensities of emission lines fed by direct collisional excitation and radiative cascades, and alter the structure of satellite features in both K - and L -shell spectra. The characteristic energy, functional form, and spatial properties of hot electron distributions in plasmas are open to characterization through their effects on high-energy continuum and line emission and on the polarization of spectral lines.

Journal Article↗

Analysis of L -shell line spectra with 50-ps time resolution from Mo X -pinch plasmas.

Mo wire X pinches typically emit several x-ray bursts from a bright spot near the crossing of the X -pinch wires. Streak camera images of L -shell line emission from Mo wire X pinches have been analyzed using a non-local thermodynamic equilibrium (NLTE) collisional-radiative atomic kinetics model, providing temperature and density profiles with approximately 50 ps time resolution over the approximately 350 ps x-ray bursts. In conjunction with nonspectroscopic measurements, the analysis is used to propose a picture of the dynamic evolution of the X -pinch plasma. The L -shell spectra from the first x-ray burst indicate an electron density near 10(22) cm(-3) and an electron temperature near 1 keV; subsequent x-ray bursts have L -shell spectra that indicate electron temperatures slightly above 1 keV and electron densities near 10(20) and 10(21) cm(-3). The size of the L -shell line-emitting region is estimated to be near 10 microm for the first x-ray burst and much larger for the later bursts. It is proposed that inner-shell excitation of low ionization stages of Mo in a microm -scale plasma region contributes to the observed radiation from the first micropinch, which typically emits a short burst of >3 keV radiation and has L -shell spectra characterized by broad spectral lines overlaying an intense continuum.

Journal Article↗

Advanced spectroscopic analysis of 0.8-1.0-MA Mo x pinches and the influence of plasma electron beams on L-shell spectra of Mo ions.

This paper presents a detailed investigation of the temporal, spatial, and spectroscopic properties of L-shell radiation from 0.8 to 1.0 MA Mo x pinches. Time-resolved measurements of x-ray radiation and both time-gated and time-integrated spectra and pinhole images are presented and analyzed. High-current x pinches are found to have complex spatial and temporal structures. A collisional-radiative kinetic model has been developed and used to interpret L-shell Mo spectra. The model includes the ground state of every ionization stage of Mo and detailed structure for the O-, F-, Ne-, Na-, and Mg-like ionization stages. Hot electron beams generated by current-carrying electrons in the x pinch are modeled by a non-Maxwellian electron distribution function and have significant influence on L-shell spectra. The results of 20 Mo x-pinch shots with wire diameters from 24 to 62 microm have been modeled. Overall, the modeled spectra fit the experimental spectra well and indicate for time-integrated spectra electron densities between 2 x 10(21) and 2 x 10(22) cm(-3), electron temperatures between 700 and 850 eV, and hot electron fractions between 3% and 7%. Time-gated spectra exhibit wide variations in temperature and density of plasma hot spots during the same discharge.

Journal Article↗

Hot-electron influence on L-shell spectra of multicharged Kr ions generated in clusters irradiated by femtosecond laser pulses.

Strong L-shell x-ray emission has been obtained from Kr clusters formed in gas jets and irradiated by 60-500-fs laser pulses. Spectral lines from the F-, Ne- Na-, and Mg-like charge states of Kr have been identified from highly resolved x-ray spectra. Spectral line intensities are used in conjunction with a detailed time-dependent collisional-radiative model to diagnose the electron distribution functions of plasmas formed in various gas jet nozzles with various laser pulse durations. It is shown that L-shell spectra formed by relatively long nanosecond-laser pulses can be well described by a steady-state model without hot electrons when opacity effects are included. In contrast, adequate modeling of L-shell spectra from highly transient and inhomogeneous femtosecond-laser plasmas requires including the influence of hot electrons. It is shown that femtosecond-laser interaction with gas jets from conical nozzles produces plasmas with higher ionization balances than plasmas formed by gas jets from Laval nozzles, in agreement with previous work for femtosecond laser interaction with Ar clusters.

Journal Article↗

FDOPA metabolism in the adult porcine brain: influence of tracer circulation time and VOI selection on estimates of striatal DOPA decarboxylation.

Different methodologies for PET data analysis influence the magnitude of estimates of blood-brain transfer coefficients and rate constants for the metabolism of FDOPA in living striatum. We now test the effects on several kinetic parameters of automatic procedures for volume of interest (VOI) selection. We also tested the sensitivity of the estimates to dynamic frame sequence duration, and produced a standard method for minimizing the variations in physiological estimates for FDOPA kinetics in minipig brain. We used minipigs because our previous work has shown them to provide an appropriate animal model for study normal and pathological cerebral DOPA metabolism using PET. Time-activity curves in striatum of adult minipigs were acquired in VOIs defined manually on MR-images, or alternatively on the basis of the radioactivity concentration based on the most radioactive voxel in the last scan frame. For all frame sequences, the relative decarboxylase activity (k(3)(D)) declined significantly (P < 0.006) as the VOI threshold declined from 95 to 70% of the most radioactive voxel. Irrespective of VOI size, the magnitude of k(3)(D) declined significantly (P < 0.001) from 0.074+/-0.008 to 0.045+/-0.005 per min (mean+/-S.E.M.) as total sequence length increased from 60 to 120 min circulation. The method of VOI selection had no significant effect on the striatum decarboxylation index of FDOPA calculated relative to the radioactivity in cerebellum (k(3)(S)).

Animals↗

Synthesis and evaluation of racemic [(11)C]NS2456 and enantiomers as selective serotonin reuptake radiotracers for PET.

Positron emission tomography (PET) radiotracers are needed for quantifying serotonin uptake sites in the living brain. Therefore, we evaluated a new selective serotonin reuptake inhibitor, NS2456, to determine whether it is suited for use in PET. Racemic NS2456 [(1RS,5SR)-8-methyl-3-[4-trifluoromethoxyphenyl]-8-azabicyclo [3.2.1]oct-2-ene] and its N-demethylated analog, racemic NS2463, selectively inhibited serotonin uptake in rat brain synaptosomes; their IC(50) values were 3000-fold lower for [(3)H]serotonin than for either [(3)H]dopamine or [(3)H]noradrenaline. The enantiomers of NS2463 were also potent inhibitors of serotonin uptake in vitro, but they failed to show stereoselectivity. Racemic NS2463 as well as its enantiomers were radiolabelled by N-methylation with C-11, yielding [(11)C]NS2456 for use in PET of the living porcine brain. The compounds crossed the blood-brain barrier rapidly and accumulated preferentially in regions rich in serotonin uptake sites (e.g., brainstem, subthalamus and thalamus). However, their binding potentials were relatively low and no stereoselectivity was found. Thus, neither racemic [(11)C]NS2456 nor its [(11)C]-labelled enantiomers are ideal for PET neuroimaging of neuronal serotonin uptake sites.

Animals↗

[14C]Serotonin uptake and [O-methyl-11C]venlafaxine kinetics in porcine brain.

As part of our program of developing PET tracers for neuroimaging of psychotropic compounds, venlafaxine, an antidepressant drug, was evaluated. First, we measured in vitro rates of serotonin uptake in synaptosomes prepared from selected regions of porcine brain. Then, we determined the pharmacokinetics of venlafaxine, [O-methyl-11C]-labeled for PET. Synaptosomal studies showed that the active uptake of [14C]5-HT differed markedly between brain regions, with highest rates in hypothalamus, raphé region, and thalamus, and lowest rates in cortex and cerebellum. PET studies showed that the unidirectional rate of uptake of [O-methyl-11C]venlafaxine from blood to brain was highest in the hypothalamus, raphé region, thalamus and basal ganglia and lowest in the cortex and cerebellum. Under normal physiological conditions, the capillary permeability-surface area (PS) product for [O-methyl-11C]venlafaxine could not be estimated, because of complete flow-limitation of the cerebral uptake. Nevertheless, a correlation occurred between the apparent partition volume of the radiotracer and the rate of active uptake of 5-HT in selected regions of the porcine brain. During hypercapnia, limitations of blood-brain transfer were observed, giving PS-products for water that were only ca. 50% higher than those of venlafaxine. Thus, under normal physiological conditions, the rate of uptake of venlafaxine from blood into brain is completely flow-limited.

Animals↗

Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling.

UNLABELLED: Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min. Hepatic arterial and portal venous blood samples and flows were measured during the scan. The dual-input function was calculated as the flow-weighted input. RESULTS: For both MG and FDG, the compartmental analysis using arterial input led to systematic underestimation of the rate constants for rapid blood-tissue exchange. Furthermore, the arterial input led to absurdly low estimates for the extracellular volume compared with the independently measured hepatic blood volume of 0.25 +/- 0.01 mL/mL (milliliter blood per milliliter liver tissue). In contrast, the use of a dual-input function provided parameter estimates that were in agreement with liver physiology. Using the dual-input function, the clearances into the liver cells (K1 = 1.11 +/- 0.11 mL/min/mL for MG; K1 = 1.07 +/- 0.19 mL/min/mL for FDG) were comparable with the liver blood flow (F = 1.02 +/- 0.05 mL/min/mL). As required physiologically, the extracellular volumes estimated using the dual-input function were larger than the hepatic blood volume. The linear Gjedde-Patlak analysis produced parameter estimates that were unaffected by the choice of input function, because this analysis was confined to time scales for which the arterial-input and dual-input functions were very similar. CONCLUSION: Compartmental analysis of MG and FDG kinetics using dynamic PET data requires measurements of dual-input activity concentrations. Using the dual-input function, physiologically reasonable parameter estimates of K1, k2, and Vp were obtained, whereas the use of conventional arterial sampling underestimated these parameters compared with independent measurements of hepatic flow and hepatic blood volume. In contrast, the linear Gjedde-Patlak analysis, being less informative but more robust, gave similar parameter estimates (K, V) with both input functions.

3-O-Methylglucose↗

[Detection of cholangiocarcinoma in primary sclerosing cholangitis by positron emission tomography].

Primary sclerosing cholangitis (PSC) predisposes to cholangiocarcinoma (CC). PET scanning can assess metabolism in vivo. The glucose analogue [18 F]fluoro-2-deoxy-D-glucose (FDG) accumulates in malignant tumours because of high glucose metabolism. PET scanning of the liver was performed after intravenous FDG in nine patients with PSC, six with PSC + CC, and five controls. "Hot spots" with radioactivity accumulation were seen in each PSC + CC patient, but not in the two other groups. Values of net metabolic clearance of FDG, K (ml min-1 100 ml-1 tissue), was in CC hot spots 1.59 to 4.17 (median, 2.34; n = 6); in reference liver tissues of these patients 0.40 to 0.69 (0.49); in PSC 0.23 to 0.53 (0.36); in controls 0.20 to 0.34 (0.31). The difference between K in CC hot spots and the other groups was statistically significant (P < 0.001). FDG-PET may detect small CC tumours and be useful in therapeutic management of PSC.

Bile Duct Neoplasms↗

Positron emission tomography of radioligand binding in porcine striatum in vivo: haloperidol inhibition linked to endogenous ligand release.

The ligands N-methylspiperone and haloperidol both bind to D(2)-like dopamine receptors. The competitive nature of the binding over a wide range of haloperidol concentrations and the effect on dopamine release have never been tested in vivo. We determined the competitive interaction between 3-N-[(11)C]methylspiperone ([(11)C]NMSP) and haloperidol binding to striatal dopamine D(2)-like receptors with positron emission tomography (PET) of pig brain. [(11)C]NMSP tomography was performed with haloperidol at five different plasma concentrations maintained constant by programmed infusion. Kinetic parameters of ligand competition for binding in the striatum were determined by deconvolving time-activity curves of the striatum and cerebellum from metabolite-corrected arterial plasma [(11)C]NMSP and haloperidol concentrations. Two types of [(11)C]NMSP-binding sites were evident in the striatum, both saturable by haloperidol administration. The preponderant or primary sites bound [(11)C]NMSP irreversibly, as dopamine D2-like receptors, while the secondary sites bound [(11)C]NMSP reversibly, as do serotonin S2 receptors. Woolf-Hanes plots revealed the predicted approximately linear relationships between the binding indices and the haloperidol plasma concentration. For the irreversible binding sites, this relationship indicated a 50% inhibitory concentration of haloperidol of 2 nM in plasma and a maximum binding capacity of 64 pmol cm(-3) in striatum. For the reversible binding sites, the relationship indicated a 50% inhibitory plasma concentration of haloperidol of 1 nM and a maximum binding capacity of 4.5 pmol cm(-3). Second-order polynomial Eadie-Hofstee-Scatchard plots were consistent with increased competition from an endogenous ligand of the irreversibly binding sites only with increasing doses of haloperidol. At the highest haloperidol dose, this hypothetical endogenous ligand had risen 6-7-fold. We contend that this reveals the release of dopamine by high concentrations of haloperidol.

Animals↗

Dynamic 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography of liver tumours without blood sampling.

Positron emission tomography (PET) using 2-[18F]fluoro-2-deoxy-D-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans with arterial blood sampling in human subjects: First, data from four patients with no liver tumours and five patients with liver tumours were used as a training group. Volumes of interest were defined in the descending aorta (aorta VOIs) by four different methods. K values were calculated based on the corresponding TACs and compared with those based on TACs of the arterial blood sample radioactivity concentrations. The aorta VOI which gave K values that were in best agreement with the K values based on the arterial blood sample measurements was called the AORTA-VOI. Use of the AORTA-VOI was subsequently tested in a test group of 19 tumour patients by comparing the K values from the AORTA-VOI with the K values based on the arterial blood sample measurements. The AORTA-VOI consisted of the sum of small regions of interest (ROIs) drawn in the centre of the aorta (approximately six pixels of 2.4x2.4 mm per transaxial slice of 3.1 mm thickness) in as many transaxial slices as possible (30-40 slices). There were no statistically significant differences between the two sets of K values. The ratio of K values in tumour tissue to K values in reference tissue was 2.1-9.7:1 (mean, 5.4:1) based on the AORTA TACs, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net metabolic clearance of FDG in dynamic PET studies of liver tumours in human subjects.

Adenocarcinoma↗

Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes.

OBJECTIVE: High intensity transient signals (HITS) representing microembolization to the brain have been found to contribute to cognitive impairment and psychoneurological dysfunction in patients carrying a mechanical aortic valve. It is unknown, whether HITS represent gaseous or solid emboli. This animal study evaluates the impact of valve orientation on HITS for two different mechanical valves with both valves implanted in their best and worst orientation, which has been defined in previous studies with respect to downstream turbulence. METHODS: In four pigs a rotation device carrying either a Medtronic Hall (MH) or St. Jude Medical (SJM) valve size 23 mm was implanted. The device allowed rotation of the implanted valves without reopening of the aorta. Approximately 30 min after weaning from extracorporeal circulation, a Doppler probe was placed on both common carotid arteries. In different orientations of the implanted valves (best and worst position), HITS were detected by the Doppler probe and recorded for ten min by a transcranial Doppler sonography device (Medilab Inc., Estenfeld, Germany). RESULTS: HITS showed significant change with rotation for both valve designs. With the major orifice of the MH oriented towards the non-coronary leaflet (optimum position) very low HITS-counts (0.8-1.7/min) were observed. In the worst orientation HITS rose to 43-66/min. For the SJM the HITS count in the optimum position was 23.4-24/min and in the worst orientation 38-48/min. CONCLUSIONS: Valve orientation has an important impact on microembolization to the brain. In the optimum orientation (large orifice facing the non-coronary leaflet) the Medtronic Hall valve showed negligible incidence of HITS. The St. Jude Medical bileaflet valve showed less variation but demonstrated significant HITS counts at any orientation. As the MH in the worst position shows significantly higher turbulent stresses than the SJM but no higher incidence of HITS, a strong correlation between turbulence and HITS was not demonstrated by this study.

Animals↗

High-intensity transient signals (HITS) as a parameter for optimum orientation of mechanical aortic valves.

BACKGROUND: In previous studies [1,2], the impact of valve orientation on the hemodynamic performance of mechanical aortic valves has been demonstrated. This study investigates Turbulence (RNS values) and High Intensity Transient Signals (HITS) as a new and objective parameter for hemodynamics in different orientations of Medtronic Hall (MH) and St. Jude Medical (SJM) aortic valves. METHODS: A rotation device carrying MH or SJM valves was implanted in 4 pigs. The device allowed valve rotation without reopening the aorta. In different orientations, turbulent shear stresses (RNS values) and HITS were measured. RESULTS: RNS and HITS changed for both valve designs in various orientations, with superior results for the MH in the hemodynamically best orientation. Downstream turbulence (RNS) and HITS varied into the same direction, but a one-to-one correlation was not observed. CONCLUSIONS: RNS and HITS vary with respect to valve orientation and design with superior results for the tilting disc valve. Both MH and SJM valves showed lower turbulence and HITS counts in their hemodynamically best orientations. HITS were related to downstream turbulence and the hemodynamic performance of the mechanical aortic valves.

Animals↗

Feasibility of detecting hypoxia in experimental mouse tumours with 18F-fluorinated tracers and positron emission tomography--a study evaluating [18F]Fluoro-2-deoxy-D-glucose.

The study was designed to investigate the binding of [18F]Fluoromisonidazole ([18F]FMISO) and [18F]Fluoro-2-deoxy-D-glucose ([18F]FDG) in a C3H mouse mammary carcinoma. Non-anaesthetized tumour-bearing animals breathing either normal air or carbogen (to reduce tumour hypoxia) were examined by PET after tracer injection. Tumours were identified by radioactive labelling and methods of defining regions of interest (ROI) in the tumours were investigated. Reference tissue was selected elsewhere in the mice and the ratio between mean radioactivity in tumour and reference tissue was compared. The results showed a correlation between the methods of identifying ROIs and a significantly lower tumour to reference tissue ratio for carbogen-treated mice compared with controls when using [18F]FMISO. Only one of the methods showed a significant difference in the tumour labelling between treatment groups using [18F]FDG. The study supports the contention that [18F]FMISO may be able to identify hypoxia in tumours, whereas a similar role for [18F]FDG is more doubtful.

Animals↗

Captopril improves oxygen and glucose extraction in pig hearts during reperfusion after cold cardioplegic storage.

The purpose of this study was to evaluate the haemodynamic and metabolic effects of captopril during reperfusion of pig hearts following 360 min global hypothermic cardioplegia and storage (HCS). The hearts were perfused with one litre of cold crystalloid cardioplegia (Bretschneider solution no. 3), excised and stored in saline at 4 degrees C for 360 min. The hearts were then reperfused with blood in a modified Langendorff model for 60 min. Left ventricular function, myocardial blood flow, and arteriovenous differences in oxygen, glucose and lactate were monitored intraoperatively and during reperfusion. Two groups of hearts were studied. Group I (captopril treated, n = 9): the pigs were pre-medicated with increasing oral doses of captopril for 3 weeks (12.5 mg-150 mg daily) and an intravenous dose (25 mg) upon arrival at the laboratory. Captopril was added to the cardioplegia (1000 microg/l) and to the reperfusion media (1000 microg/l). Group II (controls, n = 8): the pigs were given no premedication, captopril-free cardioplegia and the hearts were reperfused with captopril-free blood. Captopril increased myocardial oxygen and glucose extraction during reperfusion (p < 0.05 for both) while lactate remained unchanged after 360 min HCS. Treatments with captopril increased developed left ventricular pressure (DLVP) and relaxation (-dP/dtmax) during reperfusion (p < 0.05 for both), while contractility (+dP/dtmax) was unchanged. Heart rate was reduced in captopril-treated hearts (p < 0.05) while myocardial blood flow (MBF) was similar in the two groups. Captopril administration prior to and during HCS and postcardioplegic reperfusion improves oxygen and glucose extraction in large spontaneously beating porcine hearts during reperfusion. The underlying mechanisms seem to involve metabolic modulation, since myocardial uptake of oxygen and glucose was increased in the absence of changes in myocardial blood flow.

Angiotensin-Converting Enzyme Inhibitors↗