The effect of high performance gradients on fast gradient echo imaging.

The effect of gradient system performance on segmented k-space gradient echo imaging is presented. Three cases were investigated. First, an ideal system that has infinite slew rates and unlimited maximum gradient strengths was considered. Second, a "high speed" imaging system (2.3 (G/cm), 23 (G/cm)/ms) was considered. These two cases were compared with a "conventional" imaging system (1(G/cm), 1.67 (G/cm)/ms). It was found that substantial increases in SNR can be achieved (approximately 45%) by using high speed versus a conventional gradient system, for a TR of 6 ms. For trapezoidal gradient waveforms, there exists an optimum maximum gradient strength for a given slew rate, and any increase in gradient strength above this optimum will not be utilized by an optimized sequence. These studies have shown that increasing TR without decreasing the bandwidth is not a good way to increase SNR for constant scan time.

Algorithms↗

Tagged MR imaging in a deforming phantom: photographic validation.

PURPOSE: To validate cine magnetic resonance (MR) image tagging measurements of a deforming object by means of a precise photographic method. MATERIALS AND METHODS: A piece of silicone rubber that acted as a phantom was stretched in a cyclical fashion inside a plastic clamp driven by a respirator pump. Deformation as a function of time was measured with a rapid gradient-echo cine tagging sequence and with sequential stroboscopic photographs. Deformations from 1.0 to 1.2 (0% to 20% stretch) in the readout direction were measured over a 7-cm region of the phantom, which had a maximum standard error of +/- 0.001 with photography and a maximum standard error of +/- 0.003 with MR imaging. RESULTS: The deformation versus time values measured with MR imaging had a standard error of 0.002 about a straight line fit to the photographic deformation versus time data. These results demonstrate that the MR imaging deformation estimates were accurate and precise. CONCLUSION: The validated tagging method can now be used to evaluate MR imaging motion estimation techniques.

Artifacts↗

Advanced cardiac MR imaging of ischemic heart disease.

Important advances in rapid magnetic resonance (MR) imaging technology and its application to cardiovascular imaging have been made during the past decade. High-field-strength clinical magnets, high-performance gradient hardware, and ultrafast pulse sequence technology are rapidly making the vision of a comprehensive "one-stop shop" cardiac MR imaging examination a reality. This examination is poised to have a significant effect on the management of coronary artery disease by means of assessment of wall motion with tagging and pharmacologic stress testing, evaluation of the coronary microvasculature with perfusion imaging, and direct visualization of the coronary arteries with MR coronary angiography. This article reviews current state-of-the-art pulse sequence technology and its application to the evaluation of ischemic heart disease by means of MR tagging with dobutamine stress testing, MR perfusion imaging, and MR coronary angiography. Cutting edge areas of research in coil design and exciting new areas of metabolic and oxygen level-dependent imaging are also explored.

Cardiotonic Agents↗