PubMed Health⌕ Search

Biomedical subjects

S B Solomon

Publications and source records attributed to S B Solomon.

At least 19 recordsLinked to original sources

Robotic assisted radio-frequency ablation of liver tumors--randomized patient study.

The minimally invasive treatment of liver tumors represents an alternative to the open surgery approach. Radio-frequency ablation destroys a tumor by delivering radio-frequency energy through a needle probe. Traditionally, the probe is placed manually using imaging feedback. New approaches use robotic devices to accurately place the instrument at the target. The authors developed an image-guided robotic system for percutaneous interventions using computed tomography. The paper presents a randomized patient study comparing the manual versus robotic needle placement for radio-frequency ablation procedures of liver tumors. The results of this study show that in our case robotic interventions were a very viable solution. Several treatment parameters such as radiation exposures and procedure-times were found to be significantly improved in the robotic case.

Algorithms↗

Field tests of a radon progeny sampler for the determination of effective dose.

A two-screen sampler (an effective dosimeter), with a collection efficiency matched to the particle size response of the radon progeny dose conversion factors (DCF), obtained from the ICRP respiratory tract model as implemented in the computer code RADEP, has been developed to assess the inhalation dose from exposure to radon progeny. In order to evaluate the performance of this sampler, the second stage of a six-stage wire screen diffusion battery was designed to operate as an Effective Dosimeter. This hybrid system allowed two methods for the determination of the radon progeny DCF. For the first method, the activity size distributions, measured using the diffusion battery, were used to obtain a size-weighted DCF. A second determination of DCF was obtained directly from the fraction collected by the Effective Dosimeter. The hybrid diffusion battery was used to measure radon progeny in the Fairy Cave, Buchan, Victoria at 20-min intervals over a 30-h period. This cave had radon concentrations exceeding 2000 Bq m(-3), with low aerosol concentration and low ventilation rates. The measurements were analysed for the radon progeny PAEC, the activity size distribution, the size-weighted DCF and the effective dosimeter collected fraction. The Effective Dosimeter DCFs were determined from the collected fraction using firstly a simple linear function and then using a more complex polynomial function to correct for residual errors. For the linear factor alone, the calculated Effective Dosimeter DCFs were on average 11% lower than the equivalent size-weighted DCF values. The agreement using the polynomial function was improved markedly, with a linear regression of the DCF yielding a fitted ratio of 0.965, with an R value of 0.99. For this study, the use of the ICRP conversion convention to estimate the occupational exposure to the tour guides working in the Fairy Cave would under estimate the effective dose by up to a factor of 2.

Air Pollutants, Radioactive↗

Positron emission tomography in the detection and management of sarcomatous transformation in neurofibromatosis.

Benign neurofibromas undergo sarcomatous transformation in approximately 5% of patients with neurofibromatosis type I. The clinical and radiologic diagnosis of sarcomatous change remains difficult. Positron emission tomography with F-18 fluorodeoxyglucose is a method to assess increased glucose metabolism in malignant tissue such as sarcomas. In this case report, positron emission tomography accurately distinguished malignant from benign neurofibromas. The technique may be useful as a noninvasive screening tool for malignant transformation of neurofibromas.

Adult↗

Noninvasive vasectomy using a focused ultrasound clip: thermal measurements and simulations.

INTRODUCTION: Conventional surgical vasectomy may lead to complications including bleeding, infection, and scrotal pain. Noninvasive transcutaneous delivery of therapeutic focused ultrasound has previously been shown to thermally occlude the vas deferens. However, skin burns and inconsistent vas occlusion have presented complications. This study uses bio-heat transfer simulations and thermocouple measurements to determine the optimal ablation dosimetry for vas occlusion without skin burns. METHODS: A 2-rad ultrasound transducer mounted on a vasectomy-clip-delivered ultrasound energy at 4 MHz to the canine vas deferens co-located at the focus between the clip jaws. Chilled degassed water was circulated through an attached latex balloon, providing efficient ultrasound coupling into the tissue and active skin cooling to prevent skin burns. Thermocouples placed at the vas, intradermal, and skin surface locations recorded temperatures during ablation. Procedures were performed with transducer acoustic powers of 3-7 W and sonication times of 60-120 s on both the left and right vas deferens (n = 2) in a total of four dogs (precooling control, 3 W/120 s, 5 W/90 s, 7 W/60 s). Measurements were compared with bio-heat transfer simulations modeling the effects of variations in power and sonication time on tissue temperatures and coagulation zones. RESULTS: Active skin cooling produces a thermal gradient in the tissue during ablation, allowing sufficient thermal doses to be delivered to the vas without skin burns. However, low-power, long-duration heating produced excessive tissue necrosis due to thermal diffusion, while high power and short heating times reduced the therapeutic window and produced skin burns presumably due to direct ultrasound absorption. CONCLUSIONS: Both simulations and experiments suggest that a therapeutic window exists in which thermal occlusion of the vas may be achieved without the formation of skin burns in the canine model (power = 5-7 W, surface intensity = 1.4-1.9 W/cm2, time = 20-50 s). This range of ablation parameters will help guide future experiments to refine incisionless vasectomy using focused ultrasound.

Animals↗

Focal hepatic ablation using interstitial photon radiation energy.

BACKGROUND: Intratumoral ablative therapy is being used increasingly for the treatment of primary and secondary hepatic malignancies. The interstitial point-source photon radiosurgery system (PRS) is a novel ablative technique that uses radiation therapy similar in dosimetry to interstitial brachytherapy. STUDY DESIGN: To determine the feasibility, toxicity, and local tissue destructive capabilities of the PRS in the liver, preliminary studies in a nontumor-bearing canine model were examined. A 6-month survival study was conducted. Each animal received three radiation treatments, in the right, central, and left hepatic regions. Three low-dose treatments were delivered to each of six animals (group A), generating a 2.0-cm-diameter radiated sphere with a dose of 20 Gy at the lesion edge. Three high-dose treatments were delivered to each of six animals (group B), generating a 3.0-cm-diameter radiated sphere with 20 Gy at the lesion edge. RESULTS: The treatment reproducibly generated sharply demarcated hepatic ablative lesions proportional to the administered dose. Mean lesion diameter at 1 month was 1.6+/-0.2 cm in group A and 3.4+/-1.0 cm in group B. Lesion size was independent of intrahepatic location, including near vascular structures. PRS therapy, when applied to portal structures, resulted in hilar damage. Hilar damage appeared to be associated with arteriolar thrombosis and bile duct injury. Treatment of regions adjacent to large hepatic veins and the IVC was not associated with vessel thrombosis or stricture. CONCLUSIONS: PRS ablation is a generally well-tolerated method that results in consistent, well-demarcated, symmetric lesions of complete necrosis with minimal adjacent parenchymal injury. Application of such an approach for the treatment of liver tumors is promising.

Animals↗

Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: a comparison of two image registration methods.

STUDY OBJECTIVES: To compare two different image registration methods for accurately displaying the position of a flexible bronchoscope on a previously acquired three-dimensional CT scan during bronchoscopy. SETTING: Bronchoscopy suite of a university hospital. PATIENTS: Fifteen adult patients scheduled for nonemergent bronchoscopy. METHODS: A miniature electromagnetic position sensor was placed at the tip of a flexible bronchoscope. Previously acquired three-dimensional CT scans were registered with the patient in the bronchoscopy suite. Registration method 1 used multiple skin fiducial markers. Registration method 2 used the inner surface of the trachea itself for registration. Method 1 was objectively assessed by measuring the error distance between the real skin marker position and the computer display position. Methods 1 and 2 were subjectively assessed by the bronchoscopist correlating visual bronchoscopic anatomic location with the computer display position on the CT image. RESULTS: The error distance (+/- SD) from known points for registration method 1 was 5.6 +/- 2.7 mm. Objective error distances were not measured for method 2 because no accurate placement of the bronchoscope sensor could be correlated with CT position. Subjectively, method 2 was judged more accurate than method 1 when compared with the fiberoptic view of the airways through the bronchoscope. Additionally, method 2 had the advantage of not requiring placement of fiducial markers before the CT scan. Respiratory motion contributed an error of 3.6 +/- 2.6 mm, which was partially compensated for by a second tracking sensor placed on the patient's chest. CONCLUSION: Image registration method 2 of surface fitting the trachea rather than method 1 of fiducial markers was subjectively judged to be superior for registering the position of a flexible bronchoscope during bronchoscopy. Method 2 was also more practical inasmuch as no special CT scanning technique was required before bronchoscopy.

Biopsy↗

Left atrial relaxation and left ventricular systolic function determine left atrial reservoir function.

BACKGROUND: Determinants of left atrial (LA) reservoir function and its influence on left ventricular (LV) function have not been quantified. METHODS AND RESULTS: In an open-pericardium, paced (70 and 90 bpm) pig model of LV regional ischemia (left anterior descending coronary constriction), with high-fidelity LV, LA, and RV pressure recordings, we obtained the LA area with 2D automated border detection echocardiography, LA pressure-area loops, and Doppler transmitral flow. We calculated LV tau, LA relaxation (a-x pressure difference divided by time, normalized by a pressure), and stiffness (slope between x and v pressure points of v loop). Determinants of total LA reservoir (maximum-minimum area, cm(2)) were identified by multiple regression analysis. Different mean rates of LA area increase identified 2 consecutive (early rapid and late slow) reservoir phases. During ischemia, LV long-axis shortening (LAS, LV base systolic descent) and LA reservoir area change decreased (7.3+/-0.3 [SEM] versus 5.6+/-0.3 cm(2), P<0.001) and LA stiffness increased (1.6+/-0.3 versus 3.1+/-0.3 mm Hg/cm(2), P=0.009). Early reservoir area change depended on LA mean ejection rate (LA area at ECG P wave minus minimum area divided by time; multiple regression coefficient=0.9; P<0.001) and relaxation (coefficient=4.9 cm(2)xms/s; P<0.001). Late reservoir area change depended on LAS (coefficient=8 cm/s; P<0.001). Total reservoir filling depended on LA stiffness (coefficient=-0.31 cm(4)/mm Hg; P=0. 001) and cardiac output (coefficient=0.001 cm(2)xmin/L; P=0.002). The strongest predictor of cardiac output was LA reservoir filling (coefficient=301 L/minxcm(2); P<0.001). The v loop area was determined by cardiac output, LV ejection time, tau, and early transmitral flow. CONCLUSIONS: Two (early and late) reservoir phases are determined by LA contraction and relaxation and LV base descent. Acute LV regional ischemia increases LA stiffness and impairs LA reservoir function by reducing LV base descent.

Animals↗

Changes in porcine transmitral flow velocity pattern and its diastolic determinants during partial coronary occlusion.

OBJECTIVES: To define the mechanical determinants of transmitral flow and the effect of heart rate during regional ischemia. BACKGROUND: Myocardial ischemia changes the transmitral flow velocity pattern due to disease-induced changes in the heart's diastolic properties. METHODS: Regional ischemia was produced in 12 pigs by partially occluding the left anterior descending coronary artery until segment-length shortening in the ischemic region fell by 20%. Transmitral flow velocity patterns and their determinants were measured under two conditions, baseline and ischemia, at two heart rates, 70 and 90 beats/min. RESULTS: Regional ischemia had a significant effect on two determinants of filling: relaxation, which was slower, and chamber stiffness, which increased. These changes were associated with reduced contractility and increased myocardial stiffness, resulting in an early transmitral flow pattern that was flatter and narrower, but no change in the late flow pattern. Moderate increases in heart rate accelerated relaxation and decreased atrioventricular pressure gradient but had no effect on contractility or myocardial or chamber stiffness, resulting in an early transmitral flow pattern that was flatter and narrower and an increased late flow velocity. CONCLUSIONS: This model of regional ischemia leads to a flatter and narrower early transmitral flow velocity pattern and no change in late flow due to a combination of slowed left ventricular relaxation and increased chamber stiffness. Reflex increases in heart rate that accompany ischemia tend to mask this effect.

Animals↗

Interactive images in the operating room.

Fluoroscopy has made endourology possible, but its two dimensionality and poor tissue contrast limit its applications. Recent advances in computer technology are making it possible for surgeons to interact with three-dimensional CT and MR images. Initial interactive navigation systems tracked the position of surgical instruments on previously acquired images using optical, ultrasonic, or electromagnetic devices. More recently, real-time imaging and instrument tracking have become possible, such as with the open interventional MR scanners. The problems created by patient motion and tissue deformation during manipulation may thereby be overcome.

Diagnostic Imaging↗

Regional ischemia increases sensitivity of left ventricular relaxation to volume in pigs.

Regional ischemia impairs early diastolic filling due, in part, to changes in left ventricular relaxation. This study uses open-chest pigs instrumented with high-fidelity pressure transducers to investigate the effect of regional ischemia on the active component of relaxation independent of the passive effects of filling and the effect of left ventricular filling and stretch on the rate, duration, and extent of relaxation. During regional ischemia, active relaxation was impaired in the nonfilling ventricle, with a slower rate of relaxation. Stretching the myocardium as the ventricle fills slows the rate of relaxation more during regional ischemia than during normal perfusion, reflecting an increased sensitivity to stretch due to filling and an increased dependence of relaxation on volume. The duration of relaxation depends on the effect of regional ischemia on the end-diastolic pressure-volume relation. Stronger baseline contractile function results in an upward shift in the end-diastolic pressure-volume relation during regional ischemia and no net effect on the duration of relaxation. If this curve is shifted upward, the duration of relaxation shortens. All these effects combine to reduce the atrioventricular pressure gradient and left ventricular filling during regional ischemia.

Animals↗

Contraction-relaxation coupling: determination of the onset of diastole.

Left ventricular relaxation is dependent on afterload conditions during systole. An abrupt increase in afterload while the ventricle is actively contracting prolongs the duration of systole. An increase in afterload during ventricular relaxation shortens the duration of systole. Therefore, we hypothesized that the point during systole when an abrupt increase in afterload had no effect on the duration of systole represented the onset of ventricular relaxation. To determine when this point occurs, we performed aortic occlusions progressively throughout the duration of systole in six dogs. We determined the change in systolic time (t(sys)) after an intervention normalized to t(sys) of a control beat (t(sys,i)/t(sys, c)) as a function of systolic occlusion time as a percentage of total systolic time (t(occ)/t(sys,c)), where t(sys) is the duration from time of left ventricular end-diastolic pressure to the time of minimum first derivative of left ventricular pressure. Our results show the onset of left ventricular relaxation during normal ejection occurs at 34 +/- 3% of systolic time and approximately 16% after the onset of ejection. Thus the beginning of relaxation occurs soon after the beginning of ejection, suggesting that relaxation is modulated by variable loading conditions during ejection, significantly before what has been conventionally been assumed to be the beginning of ventricular relaxation.

Animals↗

UL-FS 49 (zatebradine) does not affect arterial baroreflex in conscious normal or aortic-constricted rats.

Heart-rate reduction is an important element of patient management during cardiac bypass surgery and in therapeutic measures for combating ischemia and relieving pain in patients with angina. UL-FS 49 is a novel bradycardic agent that purportedly acts solely on the sinoatrial node without potentially deleterious effects on arterial pressure and cardiac inotropism. However, little is known about influences of this agent on neuronal tissue and cardiovascular reflexes. Moreover, left ventricular hypertrophy, which often accompanies cardiovascular disease, is known to attenuate the arterial baroreflex and could have effects interactive with those of UL-FS 49. In this study, the effects of UL-FS 49 on the arterial baroreflex were tested in normal rats (N), rats with left ventricular hypertrophy 14 days after abdominal aortic constriction (AC), and sham-operated controls (SH). Arterial baroreflex sensitivity (BRS) was estimated as the slope of the relation between mean arterial pressure (independent variable) and the RR interval (dependent variable). At the time of study, the AC group had significantly greater mean arterial pressure than either SH or N (159 +/- 2, 122 +/- 3, and 124 +/- 3 mm Hg, respectively; mean +/- SEM, p < 0.01) and significantly greater left ventricular mass to body mass ratio than did SH (3.73 +/- 0.11, 2.33 +/- 0.11 mg/g; p < 0.01). As expected, BRS was significantly depressed in AC, compared with either SH or N (0.52 +/- 0.16, 1.48 +/- 0.12, 1.69 +/- 0.25 ms/mm Hg, respectively; p < 0.01). Despite its potent dose-dependent bradycardic effects in all three groups, UL-FS 49 did not affect BRS significantly in any group. These results show that the arterial baroreflex is largely unaffected by UL-FS 49 in both normal rats and rats with systemic hypertension and left ventricular hypertrophy.

Animals↗

Left ventricular diastolic function of remodeled myocardium in dogs with pacing-induced heart failure.

In patients with heart failure, decreased contractility resulting in high end-diastolic pressures and a restrictive pattern of left ventricular filling produces a decrease in early diastolic filling, suggesting a stiff ventricle. This study investigated the elastic properties of the myocardium and left ventricular chamber and the ability of the heart to utilize elastic recoil to facilitate filling during pacing-induced heart failure in the anesthetized dog. Elastic properties of the myocardium were determined by analyzing the myocardial stress-strain relation. Left ventricular chamber properties were determined by analyzing the pressure-volume relation using a logarithmic approach. Elastic recoil was characterized using a computer-controlled mitral valve occluder to prevent transmittral flow during diastole. We conclude that, during heart failure, the high end-diastolic pressures suggestive of a stiff ventricle are due not to stiffer myocardium but to a ventricle whose chamber compliance characteristics are changed due to geometric remodeling of the myocardium. The restrictive filling pattern is a result of the ventricle being forced to operate on the stiff portion of the diastolic pressure-volume relation to maintain cardiac output. Slowed relaxation and decreased contractility result in an inability of the heart to contract to an end-systolic volume below its diastolic equilibrium volume. Thus the left ventricle cannot utilize elastic recoil to facilitate filling during heart failure.

Animals↗

Effect of lidocaine on left ventricular pressure-volume curves during demand ischemia in pigs.

The diastolic pressure-volume curve shifts upward during demand ischemia, most likely because of changes in Ca2+ dynamics within the sarcomere. It is possible that agents that affect Na+/Ca2+ exchange, such as lidocaine, a class 1b-type Na+-channel blocker that decreases intracellular Na+, could affect the diastolic pressure-volume relationship because of indirect effects on intracellular Ca2+. Lidocaine is a drug widely used to treat arrhythmias in patients with myocardial ischemia. We studied the effects of lidocaine on diastolic dysfunction associated with demand ischemia. We compared diastolic (as represented by the shift in the diastolic pressure-volume relationship) and systolic function during demand ischemia before and after lidocaine injection. We created demand ischemia in pigs before and after administering lidocaine (5 mg/kg) in eight open-pericardium anesthetized pigs. Demand ischemia was induced by constricting the left anterior descending coronary artery and then pacing at 1.5-1.8 times the baseline heart rate for 1.5-3 min. Hemodynamics were recorded during baseline, demand ischemia, baseline after lidocaine injection, and demand ischemia after lidocaine. Lidocaine did not affect systolic function or the time constant of isovolumic relaxation, but it increased the upward shift of the diastolic pressure-volume curve during demand ischemia compared with the increase that occurred before lidocaine was administered. This result suggests that lidocaine could aggravate diastolic dysfunction in patients with ischemic heart disease.

Animals↗

Real-time bronchoscope tip localization enables three-dimensional CT image guidance for transbronchial needle aspiration in swine.

STUDY OBJECTIVE: To determine the feasibility of using real-time bronchoscope position technology coupled with previously acquired three-dimensional CT data to enhance transbronchial needle aspiration (TBNA). DESIGN: Eight swine were given percutaneously created target lesions for TBNA. A miniature position sensor was placed at the tip of a bronchoscope, and real-time position information during bronchoscopy was presented on a monitor simultaneously displaying previously acquired three-dimensional CT data. INTERVENTIONS: TBNA of target lesions and submucosal ink-spot injection of computer-generated targets. MEASUREMENTS AND RESULTS: TBNA specimens revealed successful aspiration of target material. Distances between ink marks made at computer-generated tracheal targets varied, on average (+/- SD), 4.2 mm +/- 2.6 mm from predetermined computer-distance coordinates. CONCLUSION: Real-time bronchoscope position technology coupled with previously acquired CT images may aid with TBNA of nonvisible extrabronchial lesions.

Animals↗

Performance of a diffusion barrier charcoal adsorption 222Rn monitor under conditions of varying humidity and temperature.

An investigation of the performance of a diffusion barrier, charcoal-based 222Rn monitor under several artificial environmental conditions showed that both temperature and relative humidity levels affect 222Rn uptake. A physical model was developed adequately describing the temperature effects, while an empirical model was used to summarize the combined effects of temperature and atmospheric water concentration.

Charcoal↗