PubMed Health⌕ Search

Biomedical subjects

S Beloucif

Publications and source records attributed to S Beloucif.

28 records · Page 2Linked to original sources

Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes.

We have developed novel implantable Doppler microprobes to monitor beat-by-beat stroke volume and cardiac output (CO) after cardiac surgery. In 11 adults undergoing either coronary artery bypass grafting (n = 6) or valve replacement (n = 5), Doppler microprobes were implanted on the ascending aorta or the main pulmonary artery to measure aortic blood flow (ABF) or pulmonary artery blood flow (PBF). The diameters of both vessels were determined before surgery using two-dimensional echocardiography. Stroke volume was obtained from velocity tracings measured by a 4-MHz zero-crossing pulsed Doppler flowmeter. Simultaneous measurements of Doppler and thermodilution CO (TDCO) were compared. We found the following: ABF = 1.03 TDCO - 0.22 L/min (r = 0.89); while PBF = 0.69 TDCO - 1.24 L/min (r = 0.75). Furthermore, peak flow velocity and maximum acceleration of blood in the ascending aorta were measured after inotropic stimulation with dobutamine; both values increased significantly from control values (25.2 +/- 6.1 percent and 44.6 +/- 8.6 percent, respectively, at 7.5 micrograms/kg/min). We conclude that implanted aortic Doppler microprobes provide a sensitive and reliable method to measure aortic blood flow velocity after surgery and then allow monitoring of stroke volume and CO and analysis of left ventricular function after cardiac surgery.

Aorta↗

[Nitrate derivatives and anesthesia-resuscitation: physiopathologic bases and therapeutic indications].

This review briefly describes the cellular mechanisms of nitrates and the tolerance. Nitrates activate NO production thus GMPc in the smooth muscle cell explaining their vasodilating properties even in absence of an intact endothelium. The biologic pathway of AMPc is stimulated by prostaglandin activated by nitrates. Tolerance to these agents could result from depletion of sulfhydryl radical but also from reflex cardiovascular adaptation. After a brief recall of pharmacokinetic, pharmacodynamic properties are detailed. Therapeutic use in cardiac surgery, non-cardiac surgery, controlled hypotension, aortic surgery, heart failure, unstable angina, myocardial infarction and systolic hypertension in the elderly are discussed.

Anesthesia↗

Evaluation of pulsed Doppler common carotid blood flow as a noninvasive method for brain death diagnosis: a prospective study.

Among the main causes for the relatively small number of organ donors, the delay in the diagnosis of brain death plays a major role. This prospective study was designed to evaluate whether pulsed Doppler mean and phasic common carotid blood flow (CCBF) combined with arterial and jugular venous blood gases could rapidly and specifically establish a diagnosis of brain death. CCBF was measured by an 8 MHz pulsed Doppler flowmeter, allowing measurement of the vessel diameter via a double transducer probe, which fixed the ultrasonic incidence angle. From an initial series of patients (n = 28) with an established diagnosis [brain death n = 14; severe coma with a Glasgow Coma Scale (GCS) less than 7, n = 14], the results of the logistic regression analysis process yielded the most discriminating parameters for brain death diagnosis: end-diastolic velocity (Ved - 1.4 vs. 12.7 cm/s; t = 7.67, P = 0.001) and blood flow (Qed - 13.6 vs. 121.4 ml/min). These parameters were then tested in a blind fashion on a second series of 28 comatose patients (GCS = 7). They resulted in correct diagnosis (brain death n = 14 or severe coma n = 14) for all patients. Brain death diagnosis was confirmed by clinical signs, EEG, and/or angiography. From the analysis of the overall population (n = 56), a value of Qed of less than 31.4 ml/mn indictes brain death. The authors conclude, that pulsed Doppler measurements of CCBF represent an early, low cost and noninvasive technique, the results of which may prompt legally accepted procedures, which in turn would reduce the delay required before brain death is diagnosed. Moreover, this technique could help in deciding on discontinuation of active therapy in severely injured patients.

Adult↗

Determinants of systolic and diastolic flow in coronary bypass grafts with inotropic stimulation.

Using implanted pulsed Doppler microprobes sutured on saphenous bypass grafts in ten patients we studied, 6 h after cardiac surgery, the effects of 5 and 10 micrograms.kg-1.min-1 of dobutamine on mean (Qm), systolic (Qs), and diastolic (Qd) coronary bypass graft flows, as well as on coronary systolic (integral of Qs) and diastolic (integral of Qd) blood volumes entering the myocardium per cardiac beat. Qm increased during the inotropic stimulation from 61.8 +/- 19.2 to 81.1 +/- 21.8 ml.min-1 (P less than 0.001) and resulted from an unchanged Qs and from a large increase in Qd (P less than 0.01). Qd increased more than did diastolic arterial pressure and was related to rate pressure product taken as an index of myocardial oxygen consumption (r = 0.76, P less than 0.001). Despite the dobutamine-induced increase in heart rate (P less than 0.01), integral of Qs, and integral of Qd, the systolic and diastolic inflow volumes per cardiac beat were unchanged. We conclude that increased myocardial blood supply through the saphenous vein bypass graft during inotropic stimulation by dobutamine resulted from different systolic and diastolic events. The oxygenated blood volume entering the coronary vascular bed per beat was unchanged despite tachycardia.

Coronary Artery Bypass↗

No involvement of antidiuretic hormone in acute antidiuresis during PEEP ventilation in humans.

Decreased urinary output (Vu ml/min) after institution of PEEP is attributed to a variety of mechanisms including decreased cardiac output and renal blood flow (RBF), activation of neurohormonal reflexes, increased catecholamines, plasma renin activity (PRA), and antidiuretic hormone (ADH) release. To evaluate these factors, seven normovolemic patients (36 yr +/- 13 SD), free of preexisting lung, cardiac, or renal disease, requiring continuous mandatory ventilation for neurologic reasons were studied. The authors measured or calculated: total blood volume (TBV) (51Cr); right atrial, pulmonary arterial, pulmonary wedge, and systemic pressures, cardiac index (CI); renal plasma flow (RPF) (iodohippurate sodium 131I [131I PAH] clearance); glomerular filtration rate (GFR) (creatinine clearance), free water clearance (CH2O), osmolal clearance (Cosm), fractional excretion of sodium (FENa+) and potassium (FEK+); and plasma renin activity (PRA) (ng X ml-1 X h-1), plasma ADH (pg/ml; radioimmunoassay), epinephrine (E in pg/ml), and norepinephrine (NE in pg/ml) (double-isotope radioenzymatic assay). Two conditions were studied after 90-min steady state: 1) zero PEEP (ZEEP); and 2) 15 cmH2O PEEP. PEEP caused a significant decrease in CI (-21%; P less than 0.01) and RPF (-19%; P less than 0.05) without significant decrease in GFR. A significant decrease in Vu (-55%; P less than 0.05), FENa+ (-39%; P less than 0.05) and Cosm (-36%; P less than 0.25) occurred without modification in CH2O. Plasma ADH remained in the normal range and did not increase when PEEP was applied.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Gas Analysis↗

[Ventricular tachycardia of ischemic origin. Surgical treatment by encircling thermo-exclusion using the Nd-Yag laser].

Refractory and recurrent ventricular tachycardias are a common cause of death after myocardial infarction. The occurrence of intraventricular re-entries can be prevented by a new surgical treatment based on encircling thermic exclusion. The Nd-YAG laser beam offers 2 major advantages over previous techniques: it acts rapidly with minimal myocardial damage and can even be used in patients with left ventricular dysfunction.

Coronary Disease↗

Comparison of perioperative and postoperative phasic blood flow in aortocoronary venous bypass grafts by means of pulsed Doppler echocardiography with implantable microprobes.

Although graft dimension and hemodynamic variables have been suggested as important determinants of the functional results of aortocoronary bypass grafting, there is no easy-to-use bedside method of monitoring phasic blood flow in coronary bypass grafts. We developed a miniaturized implantable silicone pulsed Doppler flow probe linked to a classic 8 MHz pulsed Doppler system. This apparatus has an adjustable range-gated time system that permits accurate measurement of diameter (D, in mm), cross-sectional blood flow velocity (Vm, in cm/sec), and coronary bypass graft flow (CBGF, in ml/min) as pi D2/4 X Vm X 60. Ten patients (55 +/- 7.2 years SD) with preoperative left ventricular ejection fractions over 45% received the implantable flow probes during the aortocoronary venous bypass procedure. Closure of the chest altered systolic and diastolic components of flow velocity and CBGF decreased from 131 +/- 65.8 to 94 +/- 55 ml/min (-28%; p less than .01). Comparison between early postoperative values (intensive care unit) and values 6 days later showed significant increases in diameter from 4.2 +/- 0.9 to 5.3 +/- 0.9 mm (p less than .01) and in CBGF from 130 +/- 112 to 204 +/- 86 ml/min (p less than .01). We conclude that the implantable pulsed Doppler microprobe is a sensitive bedside method for monitoring aortocoronary bypass graft diameter and blood flow in the postoperative period.

Blood Flow Velocity↗