PubMed Health⌕ Search

Biomedical subjects

S Benderbous

Publications and source records attributed to S Benderbous.

21 records · Page 2Linked to original sources

23Na magnetic resonance imaging: distribution of brine in muscle.

Magnetic resonance imaging (MRI) has been used to characterize tissues in morphological studies. Here, 23Na NMR imaging was used to study the distribution in muscle of brine (5 M NaCl), injected before onset of rigor mortis. First, the distribution of brine was monitored in excised muscle from rabbits for 6 hr following arterial brine injection. Immediately after injection, distribution was clearly heterogeneous. After 6 hr, a steady state was achieved but the observed brine distribution was not fully homogeneous. Second, the same was done for ham processed in various ways (tumbling, cooking). Tumbling increased the homogeneity of distribution in our experimental conditions but only cooking afforded full homogenization of brine in ham. Concentrations of NMR-visible sodium in the muscles were appreciably lower than the expected values calculated from the volume of injected brine. The invisible sodium presumably has T2 values which are too short compared with the echo time in our conventional spectrometer.

Animals↗

MR assessment of iodinated contrast-medium-induced nephropathy in rats using ultrasmall particles of iron oxide.

The purpose of this study was to determine the diagnostic value of ultrasmall particles of iron oxide (USPIO)-enhanced MR imaging at different concentrations to evaluate experimental nephropathy. This study was conducted in 23 uninephrectomized rats using a model of iodinated contrast media-induced renal failure. Eleven rats received selective intra-arterial renal administration of diatrizoate (370 mg I/ml) and were compared to two control groups, including five animals injected with isotonic saline and seven noninjected animals. MR imaging was performed 28 hours after the procedure, including T1- and T2-weighted images before and after intravenous administration of successively 5 mumol Fe/kg and 60 mumol/kg of USPIO. Results were interpreted qualitatively and quantitatively with respect to pathologic data, and differences were studied statistically. The maximal signal intensity decrease was noted in normal kidneys in cortex (-65 +/- 4%) and medulla (-84 +/- 5%) on T2-weighted images after injection of 60 mumol/kg of USPIO. At this dose, diseased kidneys displayed less signal intensity decrease than normal kidneys on T2-weighted images (p = .05). Moreover, qualitative analysis showed that the highest sensitivity and specificity to diagnose kidney involvement were obtained with T2-weighted MR images (75% and 91%, respectively) when 60 mumol/kg of USPIO were used (p < .01). USPIO should be useful for in vivo evaluation of the severity of experimentally induced iodinated contrast media renal impairment in animals.

Animals↗

Ultrasmall superparamagnetic iron oxide particles (AMI 227) as a blood pool contrast agent for MR angiography: experimental study in rabbits.

The purpose of this study was to evaluate the contribution of an ultrasmall superparamagnetic iron oxide particles (USPIOs) based contrast agent (AMI 227), in a transverse three-dimensional time-of-flight TONE MR angiography sequence of abdominal aorta in rabbits. The main goal was to assess improvement in the visualization of small arteries such as renal arteries, when using such a sequence. Imaging experiments were performed on a 1.5 T magnet, using a transverse 3D time-of-flight (TOF) tilted optimized nonsaturating excitation (TONE) sequence with magnetization transfer suppression. The contrast media used were composed of a USPIO core surrounded by a dextran-surfactant (AMI 227). Different concentrations of AMI 227 were evaluated in 12 rabbits. Concentrations varied within the range 8.5-34 micromol Fe/kg - bw: 8.5 micromol Fe/kg (three rabbits); 17 micromol Fe/kg (three rabbits); 25.5 micromol Fe/kg (three rabbits); 34 micromol Fe/kg (three rabbits). A visual analysis based on the improvement of visualization of small arteries (renal arteries) on MIP images and a quantitative analysis based on the percentage of contrast enhancement of the aorta plotted against distance in the slab from the top edge of the acquisition volume were obtained. A signal-to-noise ratio enhancement of the distal part of the aorta and only improvement in the delineation of the renal arteries were noted when using low concentrations of the contrast media. A loss of signal-to-noise ratio of the aorta and a decrease in arterial visualization were respectively noted with higher concentration of contrast media. In this experimental study, using a transverse three-dimensional TOF TONE MR angiography sequence of renal arteries, in which sequence the saturation effect is minimized, the use of AMI 227 allows only improvement in the delineation of small arteries when using low concentrations of contrast media.

Animals↗