PubMed Health⌕ Search

Biomedical subjects

S Bize

Publications and source records attributed to S Bize.

5 recordsLinked to original sources

Search for variations of fundamental constants using atomic fountain clocks.

Over five years, we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser-cooled 133Cs and 87Rb atomic fountains with an accuracy of approximately 10(-15). These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies: d/dt ln([(nu(Rb))/(nu(Cs))]=(0.2+/-7.0)x 10(-16) yr(-1) (1sigma uncertainty). The same limit applies to a possible variation of the quantity (mu(Rb)/mu(Cs))alpha(-0.44), which involves the ratio of nuclear magnetic moments and the fine structure constant.

Journal Article↗

Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock.

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d(10)6s (2)S(1/2)(F=0)<-->5d(9)6s(2) (2)D(5/2)(F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/-7 x 10(-15) yr(-1) (1sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs)(m(e)/m(p))alpha(6.0) at the same level.

Journal Article↗

Controlling the cold collision shift in high precision atomic interferometry.

We present a new method based on a transfer of population by adiabatic passage that allows one to prepare cold atomic samples with a well-defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountain accuracy at the 10(-16) level realistic. With improvements, the adiabatic passage would allow measurements of density-dependent phase shifts at the 10(-3) level in high precision experiments.

Journal Article↗

Cold collision frequency shifts in a 87Rb atomic fountain.

We present measurements of cavity frequency pulling and collisional frequency shifts in a 87Rb fountain with a frequency resolution of 3x10(-16). Agreement with theory is found for the cavity pulling and the measured collisional shifts. The clock shift is found at least 50 times smaller than in 133Cs.

Journal Article↗