[Effect of qualitative stenosis characteristics on the quality of measurements of various QCA systems].

Reproducibility and accuracy of in vitro measurements are very high using recently developed QCA systems. We analyzed the impact of lesion characteristics ad the image quality on the quality of measurements under clinical conditions. For the study we selected 57 coronary artery lesions which had a clinically relevant distribution for stenosis severity, lesion characteristics, and image quality. Every effort was made to eliminate procedural sources of error. Three investigators measured each lesion five times with each of three QCA systems (AWOS, Cardio and CMS). Only the measurements of the minimal stenosis diameter were analyzed. The precision of all the measurements was high with the AWOS (0.04 mm), the Cardio (0.05 mm), and the CMS systems (0.06 mm). Variability of measurements increased for the following criteria: Ambrose-III morphology (CMS 0.082 mm), surface irregularities (Cardio 0.069 mm, CMS 0.073 mm), TIMI I (Cardio 0.084 mm, CMS 0.0121 mm), and moderate image quality (CMS 0.07 mm). There were no differences in the precision of the measurements in the other groups of lesion characteristics. There were no relevant differences in any of the measurements between the systems (AWOS-Cardio -0.07 mm, AWOS-CMS-0.11 mm, Cardio-CMS-0.04 mm). Smaller diameters were measured with the AWOS system than with the CMS and the Cardio systems when the lesion was calcified (AWOS-Cardio-0.109 mm, AWOS-CMS-0.161 mm). This was only a trend, however, and did not reach statistical significance, which was also true for the other differences found between the systems according to various lesion characteristics. In summary, we found that the measurement quality of the QCA systems used in this study is not altered by the underlying lesion characteristics or the image quality.

Coronary Angiography↗

Comparison of QCA systems.

AIMS: Excellent agreement between different 'second generation' systems for quantitative coronary arteriography (QCA) has been found in in vitro measurements. To verify the quality and stability of QCA when used in clinical practice, three QCA systems (AWOS, Cardio, and CMS) were used in a representative set of coronary artery lesions. METHODS AND RESULTS: This set consisted of angiographic stenosis images of 57 patients which varied in stenosis severity and morphology. The process of image acquisition, calibration, and measurement was strictly standardized to eliminate procedural sources of error. Three observers performed QCA five times in each lesion with each QCA system. Interobserver variability was low (Dnorm 0.01-0.05 mm, Dmin 0.01-0.02 mm, %stenosis 0.3-0.7%). Values of system precision were excellent (Dnorm 0.11-0.13 mm, Dmin 0.04-0.06 mm, %stenosis 2.1-2.6%). Comparison of measurements between three QCA systems revealed good agreement (range of mean differences for Dnorm 0.03-0.12 mm, Dmin 0.04-0.11 mm, and %stenosis 0.5-3.6%) and high correlation (corr 0.902-0.977). There was a tendency to measure smaller values for Dmin and consequently to identify more severe stenoses with the AWOS system than with the Cardio and CMS systems. All QCA results were compared to measurements done with the Brown Dodge method to reveal failure of the QCA measurements. These results showed excellent agreement without any systematic deviation (mean differences for Dnorm 0.01-0.08 mm, Dmin 0.02-0.06 mm, and %stenosis 1.3-1.8%). None of the differences were statistically significant. CONCLUSION: We therefore conclude that using the defined version of the AWOS, Cardio, and CMS systems, there is no difference in precision or accuracy when used for QCA of coronary artery lesions.

Algorithms↗