Utilization of a pressure-sensing monitor to improve in-flight chest compressions.

Previous research at the Division of Air Medical Services at East Carolina University School of Medicine has demonstrated impairment of chest compression efficacy in the setting of an airborne BO-105 helicopter. This study was undertaken to determine whether in-flight compression efficacy could be improved with utilization of a pressure-sensing monitor providing real-time feedback during cardiopulmonary resuscitation (CPR). Ten flight nurses each performed two minutes of in-flight chest compressions on a mannequin that electronically assessed compression depth and hand placement. The session was then repeated using the pressure-sensing device. The mean proportion of correct compressions (95.7 +/- 3.2%) achieved with utilization of the pressure-sensing monitor was significantly higher (P < .01) than the corresponding proportion for the control group (33.4 +/- 12.1%). This study demonstrated that the difficulties of performing effective in-flight chest compressions are largely overcome with utilization of a pressure-sensing device providing real-time feedback on compression efficacy.

Aerospace Medicine↗

A computer directed pneumatic tube system: its effects on specimens.

When the new Erie County Medical Center (Buffalo, NY) was built, a pneumatic tube network, manufactured by Mosler Airmatic and Electronic Systems Company, was installed. This network, called the Mosler System 4000, was designed to handle 600 transactions per hour in the hospital, and therefore had to have a high carrier speed (8m/sec). When blood specimens were sent through the system, blood cells were slightly damaged and lactic dehydrogenase activity in the serum was consistently elevated. But neither acidic phosphatase, potassium, blood gases nor urinary casts were significantly affected by tube transport.

Blood↗

The effectiveness of esophageal stethoscopy in a simulated in-flight setting.

PURPOSE: Previous research has confirmed the inability of flight nurses in an airborne BO-105 helicopter to hear breath sounds using normal or amplified transthoracic stethoscopy. The purpose of this study was to determine whether esophageal stethoscopy enabled effective auscultation of breath sounds in a simulated in-flight environment. METHODS: The cabin-sound environment of an in-flight BO-105 was recorded and recreated in an audiology laboratory, where five flight nurses were evaluated listening to taped breath sounds via an esophageal stethoscope. This audiotape model, validated in a previously published study, used a tape consisting of 24 20-second segments. Each segment, the beginning of which was marked with a beep signal, consisted of 20 seconds of silence or breath sounds. The distal (esophageal) end of the esophageal stethoscope was attached to the tape recorder; the intensity level of breath sounds heard at the stethoscope earpiece was calibrated to equate the sound level of actual esophageal breath sounds recorded on a volunteer. RESULTS: All nurses correctly identified the 24 taped segments as silent or including breath sounds 100% of the time. CONCLUSION: In the simulated environment tested, esophageal stethoscopy enabled 100% accuracy in identification of breath sounds, as compared with previously reported 0% efficacy for standard transthoracic auscultation. Study in the actual patient-care environment is indicated to confirm the usefulness of esophageal stethoscopy in the in-flight setting.

Air Ambulances↗

Red cabin lights impair air medical crew performance of color-dependent tasks.

INTRODUCTION: Red cabin lighting is often used for nighttime patient transports in helicopters. This study was conducted to determine if red lighting results in impairment of color-dependent tasks. METHODS: An emergency medical services pilot adjusted red lighting in a BO-105 cabin to maximum acceptable intensity. Thirteen emergency room residents were shown positive and negative CO2 detectors and skin-colored and cyan-tinted rubber masks; percentages of correctly identified masks and detectors were noted. Subjects also read drug name and amount from 12 medication labels. Wilcoxon analysis (p = 0.05) was used to compare label reading accuracy between two groups: control (black/white lettering/background) and red (red lettering or background). RESULTS: Percentages of accurately identified masks and detectors in the red light setting were as follows: normal mask 61.5%, cyanotic mask 30.8%, negative and positive CO2 detectors 46.2%. Ability to correctly read medication labeling was significantly (p = 0.003) greater in control (76.9 +/- 10.9%) as compared to red groups (16.3 +/- 13.4%). CONCLUSION: Red cabin lighting appears to impair performance of certain critical tasks requiring color discernment. Consideration of this by medical crews working under red light conditions could reduce risk for patient-care errors.

Air Ambulances↗