Persistent high signal on diffusion-weighted MRI in the late stages of small cortical and lacunar ischaemic lesions.

Diffusion-weighted imaging (DWI) is very sensitive to early brain infarcts. However, the late stages have been insufficiently studied. Infarcts in small vessel disease are often multiple and of different ages, and differentiation between new and old lesions might be difficult. We have therefore studied the change with time in DWI of small (< 3 ml) ischaemic lesions. We imaged 21 patients with an acute lacunar syndrome and a lesion visible on early DWI. They all had three MRI examinations 12-58 h (early), 7-16 and 54-144 days after the onset of stroke; 10 patients with high DWI signal on the third examination had a fourth examination 12-28 months after the stroke. MRI was performed at 1.5 T, using echo-planar DWI with 7 b-values from 0 to 1200 x 10(6) s/m2 and conventional T2-weighted imaging. After 7-16 days 18 of 21 lesions gave high signal on DWI, and 12/16 measurable lesions had a decreased apparent diffusion coefficient (ADC). After 54-144 days ten lesions still gave high DWI signal and two still had an ADC below normal. On the fourth examination there was no remaining high DWI signal and all ADC were higher than normal.

Brain↗

Pre-operative evaluation with MR in tetralogy of fallot and pulmonary atresia with ventricular septal defect.

PURPOSE: To assess whether MR imaging could replace angiography in preoperative evaluation of patients with tetralogy of Fallot and pulmonary atresia with ventricular septal defect (VSD), especially since the surgical correction was done earlier than was previously the rule. MATERIAL AND METHODS: Fourteen patients with tetralogy of Fallot (n = 10) or pulmonary atresia with VSD (n = 4), mean age 7.5 +/- 4.4 months, were evaluated with angiocardiography and MR before definitive surgical correction. RESULTS: There was good diagnostic agreement between the two modalities when evaluating right ventricular outflow obstruction; 86% for valvular and 93% for supravalvular stenosis, but the agreement was somewhat lower for the subvalvular obstruction (57%). Surgery findings, however, were in favour of MR in 5 patients concerning the subvalvular right ventricular outflow tract obstruction. MR images identified all stenoses in the right and left pulmonary arteries, but overlooked one stenosis in the main pulmonary artery. MR could evaluate patency in all palliative shunts. CONCLUSION: Even in this young age group, MR imaging offers a good alternative to angiocardiography for the pre-operative evaluation of the right ventricular outflow tract, the main pulmonary artery and the proximal right and left pulmonary arteries, before definitive surgical correction of tetralogy of Fallot and pulmonary atresia with VSD.

Abnormalities, Multiple↗

Perfusion-related parameters in intravoxel incoherent motion MR imaging compared with CBV and CBF measured by dynamic susceptibility-contrast MR technique.

OBJECTIVE: Perfusion-related parameters obtained by intravoxel incoherent motion (IVIM) MR imaging (MRI) were compared with cerebral blood volume and flow (CBV and CBF), retrieved by dynamic susceptibility-contrast (DSC) MRI. MATERIAL AND METHODS: Twenty-eight volunteers (average age 68.5 years) were investigated. Spin-echo echo-planar imaging with IVIM-encoding gradients was employed (36 different b values, 0-1200 s/mm2). The perfusion fraction and the pseudo-diffusion coefficient were calculated for regions in thalamus gray matter and frontal white matter, using asymptotic and full fitting. In DSC-MRI, a Gd-DTPA-BMA contrast-agent bolus was monitored using simultaneous-dual FLASH. Deconvolution of the measured tissue concentration-versus-time curve with an arterial input function from the carotid artery was applied, and maps of CBV and CBF were calculated. RESULTS: The correlation between the perfusion fraction and CBV was r=0.56 (p<0.0000006) using asymptotic fitting, and r=0.35 (p<0.0004) when full fitting was applied. Average CBF was 41.5 ml/(min 100 g), to be compared with the IVIM-based value of 63.6 ml/(min 100 g), obtained from the median value of the pseudo-diffusion coefficient in combination with assumptions about capillary network structure. CONCLUSION: The IVIM concept provided results that agreed reasonably with conventional CBV and CBF. The non-linear fitting to noisy signal data was problematic, in accordance with previously presented simulations.

Aged↗

MR evaluation ex vivo and in vivo of a covered stent-graft for abdominal aortic aneurysms: ferromagnetism, heating, artifacts, and velocity mapping.

Magnetic resonance imaging (MRI) safety was evaluated at 1.5 T in a covered nickel titanium stent-graft (Vanguard) used for endovascular treatment of abdominal aortic aneurysms (AAAs). Imaging artifacts were assessed on MRI with contrast-enhanced (CE) three-dimensional (3D) MR angiography (MRA) and spiral computed tomography (CT) in 10 patients as well as ex vivo. Velocity mapping was performed in the suprarenal aorta and femoral arteries in 14 patients before and after stent-graft placement. For comparison it was also performed in six healthy volunteers. No ferromagnetism or heating was detected. Metal artifacts caused minimal image distortion on MRI/MRA. The artifacts disturbed image evaluation on CT at the graft bifurcation and graft limb junction. No significant differences in mean flow were found in patients before and after stent-graft placement. Our study indicates that MRI at 1.5 T may be performed safely in patients with the (Vanguard) stent-graft. MRI/MRA provides diagnostic image information. Velocity mapping is not included in our routine protocol.

Aortic Aneurysm, Abdominal↗

High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging.

Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).

Adult↗

Clinical lacunar syndromes as predictors of lacunar infarcts. A comparison of acute clinical lacunar syndromes and findings on diffusion-weighted MRI.

OBJECTIVES: To evaluate if patients with acute lacunar syndromes have acute lacunar infarcts or other types of cerebral lesions on diffusion-weighted MRI. METHODS: Patients with acute lacunar syndromes underwent echo-planar diffusion MRI of the brain within 3 days after stroke onset. Localization and size of lesions with hyperintense signal were determined, compared with clinical characteristics and with findings on follow-up T2-weighted MRI. RESULTS: Twenty-three patients participated in the study. Thirteen patients had pure motor stroke, 1 pure sensory stroke, 8 sensorimotor stroke, and 1 ataxic hemiparesis. Twenty-two patients had at least one lesion with increased signal on diffusion-weighted MR images. These acute lesions were in the internal capsule/ basal ganglia/thalamus in 13 patients, subcortical white matter in 5 patients, brainstem in 2 patients, cortex (multiple small lesions) in 1 patient, and cortex + basal ganglia in 1 patient. The median volume of the lesions was 0.6 ml on the initial examination and on follow-up, of 17 patients after 1 to 5 months, 0.5 ml. CONCLUSIONS: Almost all patients with acute ischemic lacunar syndromes have acute lesions on echo-planar diffusion-weighted MRI within 3 days after stroke onset. These lesions are mostly small and subcortical, compatible with lacunar infarcts caused by single penetrating artery occlusion, but in a minor proportion of patients (2 of 23 in our study) a cortical involvement is found.

Acute Disease↗

Radiological diagnosis of acute stroke. Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging.

PURPOSE: To compare conventional MR imaging, echo-planar diffusion-weighted imaging (EP-DWI) and spin-echo diffusion-weighted imaging (SE)-DWI at radiological diagnosis of acute stroke. MATERIAL AND METHODS: Twenty-seven patients (30-85 years old) were examined. Clinical examination was performed before MR imaging. All MR examinations were assessed by an experienced neuroradiologist blinded to clinical findings. RESULTS: In EP-DWI, every patient had a lesion corresponding to the clinical findings. EP-DWI was used as the gold standard. In conventional PD+T2 imaging, 23/59 focal lesions were interpreted as acute, which was false in 11 lesions, and 36/59 lesions were considered to be old, 6 were in fact acute. Nine acute lesions were only detected retrospectively and 12 acute lesions were not detected at all on PD+T2. SE-DWI including the apparent diffusion coefficient correlated fairly well with EP-DWI but the procedure was impractical. CONCLUSION: EP-DWI is reliable for diagnosis of early ischemic stroke, while SE-DWI performs reasonably well. Conventional PD+T2 imaging is not reliable for diagnosis of early ischemia.

Acute Disease↗

Triggering in quantitative diffusion imaging with single-shot EPI.

PURPOSE: The aim of this study was to evaluate any possible effects of brain motion, CSF pulsations and other possible sources of physiological motion in electrocardiographic (ECG) triggered and non-triggered single-shot echo-planar imaging (EPI) measurements of diffusion. MATERIAL AND METHODS: Three different triggering protocols were evaluated in 6 healthy volunteers: 1) ECG triggering with time delay (TD) 100 ms; 2) ECG triggering with TD 400 ms; and 3) no triggering at all. RESULTS: The results obtained showed that white matter mean apparent diffusion coefficient (ADC) values were similar for all triggering protocols and that the reproducibility in ADC measurements using diffusion-weighted (DW) EPI was good. The average standard deviation of the ADC values was, however, higher for ADC maps obtained without ECG triggering. CONCLUSION: The use of prospective diastolic ECG triggering significantly improves the accuracy of quantitative diffusion measurements but for routine clinical diffusion imaging, where quantitative data is of less importance, the accuracy obtained without ECG triggering can be considered adequate.

Adult↗

Quantitative diffusion coefficient maps using fast spin-echo MRI.

In this work, we have evaluated the performance of a diffusion-sensitive fast spin-echo (FSE) pulse sequence. The proposed pulse sequence utilises velocity-compensating diffusion-encoding gradients and includes the collection of navigator echoes. Spoiler gradients were inserted in the slice-selecting direction to minimise effects from stimulated echoes. Calculations of the b values showed that cross-terms between imaging gradients and diffusion gradients only led to a marginal increase of b values. Pixel-wise calculation of apparent diffusion coefficient (ADC) maps was performed numerically, considering cross-terms between diffusion-encoding and imaging gradients. The sequences investigated used echo train lengths of 16, 8 and 4 echoes and were encoded in either the slice-, frequency- or phase-encoding direction. In order to allow for higher b values a pulse-sequence version using non-motion compensating diffusion-encoding gradients was written. Phantom measurements were performed and the diffusion coefficients of water and acetone were reasonable. Seven healthy volunteers (age 28-50 years) were examined and apparent diffusion coefficient values agreed well with expected values. Diffusion-weighted images, apparent diffusion coefficient maps and images corresponding to the trace of the diffusion tensor of good quality were retrieved in vivo.

Adult↗

MRI thermometry in phantoms by use of the proton resonance frequency shift method: application to interstitial laser thermotherapy.

In this work the temperature dependence of the proton resonance frequency was assessed in agarose gel with a high melting temperature (95 degrees C) and in porcine liver in vitro at temperatures relevant to thermotherapy (25-80 degrees C). Furthermore, an optically tissue-like agarose gel phantom was developed and evaluated for use in MRI. The phantom was used to visualize temperature distributions from a diffusing laser fibre by means of the proton resonance frequency shift method. An approximately linear relationship (0.0085 ppm degrees C(-1)) between proton resonance frequency shift and temperature change was found for agarose gel, whereas deviations from a linear relationship were observed for porcine liver. The optically tissue-like agarose gel allowed reliable MRI temperature monitoring, and the MR relaxation times (T1 and T2) and the optical properties were found to be independently alterable. Temperature distributions around a diffusing laser fibre, during irradiation and subsequent cooling, were assessed with high spatial resolution (voxel size = 4.3 mm3) and with random uncertainties ranging from 0.3 degrees C to 1.4 degrees C (1 SD) with a 40 s scan time.

Animals↗

Quantification of low-velocity motion using a navigator-echo supported MR velocity-mapping technique: application to intracranial dynamics in volunteers and patients with brain tumours.

Gradient-echo pulse sequences with velocity-encoding gradients of 22.5-25 mT/m, were used for brain-motion and CSF-flow studies. To reduce motion artifacts, a phase-correction technique based on navigator echoes was evaluated. Three patients with right-sided parietal tumours were investigated; one astrocytoma grade III-IV, one astrocytoma grade I-II and one benign meningioma. In healthy volunteers, a maximal brain-tissue velocity of (0.94 +/- 0.26) mm/s (mean +/- 1SD) was observed, which is consistent with previously presented results. The phase correction was proven useful for reduction of artifacts due to external head movements in modulus and phase images, without loss of phase information related to internal motion. The tissue velocity within the astrocytomas was low during the entire cardiac cycle. An abnormally high rostral velocity component was, however, observed in the brain tissue frontal to the astrocytomas. In all patients, an abnormal CSF flow pattern was observed. The study of brain motion may provide further understanding of the effects of tumours and other pathological conditions in the brain. When considering intracranial motion as a source of error in diffusion/perfusion MRI, the present study suggests that a pathology can alter the properties of brain motion and CSF flow considerably, leading to a more complex impact on diffusion/perfusion images.

Adult↗

The perfusion fraction in volunteers and in patients with ischaemic stroke.

The fractional volume of capillary blood, i.e. the perfusion fraction f, was measured with the aid of an echo-planar imaging protocol originally designed for the measurement of water diffusion. In healthy volunteers, reasonable f values were obtained. In patients with cerebral ischaemic stroke, a marked decrease in the f value was seen in the infarcted region as compared with corresponding values in the contralateral hemisphere. We suggest that perfusion-fraction measurements may add to the diagnostic value of water-mobility examinations in patients with ischaemic disease.

Adult↗

Postoperative pulmonary vascular supply in congenital heart disease evaluated with MR imaging at 0.3 T.

The aim of this study was to investigate the usefulness of static spin-echo MR imaging at low field strength in evaluating postoperative pulmonary arterial supply. Twenty-seven patients operated on for complex congenital heart disease underwent cardiac MR imaging: 27 stenoses in 20 patients and 4 aneurysms were present in the material. Five of the overlooked stenoses were located in the ventricular outflow tract or in the valvular region. All four aneurysms were well depicted. The final diagnosis were based on two-dimensional echocardiography, Doppler and invasive studies. MR correctly evaluated the pulmonary arterial supply in 21 patients. In two cases the evaluation was incomplete and in the remaining four patients MR failed to show the stenoses. MR imaging at 0.3 T is an effective non-invasive tool for postoperative evaluation of pulmonary arteries.

Adolescent↗

Use of an enhanced gradient system for diffusion MR imaging with motion-artifact reduction.

PURPOSE: A spin-echo diffusion-sensitized pulse sequence using high gradients (23 mT/m) is introduced. MATERIAL AND METHODS: In order to minimize motion artefacts, velocity-compensating gradients, ECG-triggering and post-processing with phase correction and raw data averaging using navigator echoes was performed. The in vitro ratio of diffusion coefficients for water and acetone was determined and the water self-diffusion coefficient at different temperatures was evaluated. The pulse sequence was tested in 7 healthy volunteers and in 2 tumour patients with astrocytomas of grades I-II and III-IV. Both single-slice and multi-slice techniques were used. RESULTS: The incorporation of phase correction clearly improved the quality of both diffusion-encoded images and the calculated diffusion maps. Mean values of the diffusion coefficients in vivo were for CSF 2.66 x 10(-9) m2/s and for white and grey matter 0.69 x 10(-9) m2/s and 0.87 x 10(-9) m2/s, respectively. CONCLUSION: Velocity-compensating gradients in combination with a high gradient strength were shown to be useful for in vivo diffusion MR imaging.

Adult↗

Vertical field MR imaging of upper thorax and spine in small children. Evaluation of a new surface coil.

To improve image quality in a vertical field MR imaging unit, operating at low field strength (0.3 T), we have designed a half-elliptical coil for use in the upper thoracic region of small children. Our intention was also to shorten the examination time, which until now has been long, because several scans with different coils have been necessary to cover the thoracic region. The experimental coil is designed so that a child's shoulders fit into the central region. The coil consists of 2 serially connected cable-loops, mounted on a foam rubber vest. The coil performance was tested in a phantom and improvements relative to standard coils were demonstrated in in vivo studies. The results indicate that by using the half-elliptical coil, the signal-to-noise (S/N) ratio can be improved by a factor of 2 to 3 in the thoracic region of a child.

Child↗

Theoretical and experimental evaluation of phase-dispersion effects caused by brain motion in diffusion and perfusion MR imaging.

We investigated intravoxel phase dispersion caused by pulsatile brain motion in diffusion spin-echo pulse sequences. Mathematical models were used to describe the spatial and temporal velocity distributions of human brain motion. The spatial distribution of brain-tissue velocity introduces a phase spread over one voxel, leading to signal loss. This signal loss was estimated theoretically, and effects on observed diffusion coefficient and perfused capillary fraction were assessed. When parameters from a diffusion pulse sequence without motion compensation were used, and ECG triggering with inappropriate delay times was assumed, the maximal signal loss caused by brain-motion-induced phase dispersion was predicted to be 21%. This corresponds to a 95% overestimation of the diffusion coefficient, and the perfusion-fraction error was small. Corresponding calculations for motion-compensated pulse sequences predicted a 1% to 1.5% signal loss due to undesired phase dispersion, whereas experimental results indicated a signal loss related to brain motion of 4%.

Adult↗