Successful use of recombinant factor VIIa in a patient with intractable bleeding during extracorporeal membrane oxygenation.

Bleeding is still the most common complication during extracorporeal membrane oxygenation (ECMO) for temporary cardio-circulatory support. We present a case of a young man suffering from intractable hemorrhage during ECMO support, who was pre-treated with glycoprotein IIb/IIIa receptor antagonist Tirofiban due to a suspicion of myocardial ischemia. After failure of conventional hemostatic means, hemostasis was achieved by the donation of recombinant Factor VIIa (rFVIIa). Aspects of bleeding control during extracorporeal circulatory support, the use of Tirofiban and rFVIIa are discussed.

Adolescent↗

Prediction of fluid responsiveness in patients during cardiac surgery.

BACKGROUND: Left ventricular stroke volume variation (SVV) has been shown to be a predictor of fluid responsiveness in various subsets of patients. However, the accuracy and reliability of SVV are unproven in patients ventilated with low tidal volumes. METHODS: Fourteen patients were studied immediately after coronary artery bypass grafting (CABG). All patients were mechanically ventilated in pressure-controlled mode [tidal volume 7.5 (1.2) ml kg(-1)]. In addition to standard haemodynamic monitoring, SVV was assessed by arterial pulse contour analysis. Left ventricular end-diastolic area index (LVEDAI) was determined by transoesophageal echocardiography. A transpulmonary thermodilution technique was used for measurement of cardiac index (CI), stroke volume index (SVI) and intrathoracic blood volume index (ITBI). All variables were assessed before and after a volume shift induced by tilting the patients from the anti-Trendelenburg (30 degrees head up) to the Trendelenburg position (30 degrees head down). RESULTS: After the change in the Trendelenburg position, SVV decreased significantly, while CI, SVI, ITBI, LVEDAI, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) increased significantly. Changes in SVI were significantly correlated to changes in SVV (r=0.70; P<0.0001) and to changes in LVEDAI, ITBI, CVP and PAOP. Only prechallenge values of SVV were predictive of changes in SVI after change from the anti-Trendelenburg to the Trendelenburg position. CONCLUSIONS: In patients after CABG surgery who were ventilated with low tidal volumes, SVV enabled prediction of fluid responsiveness and assessment of the haemodynamic effects of volume loading.

Aged↗

Epicardial echocardiography for correct placement of the intracardial biventricular assist device (Impella).

BACKGROUND: Correct placement of the intracardial biventricular assist device (Impella) as a supporting system for off-pump coronary surgery is routinely checked by transesophageal echocardiography and invasive pressure measurements. However, it remains difficult to verify the accurate position of the right heart system when the posterior wall is exposed. METHODS: In 23 patients undergoing augmented beating heart CABG surgery, the correct placement of the lmpella-system was controlled by TEE as well as by a new 15-6 L epicardial echotransducer (EE) (Agilent, Andover, MA). RESULTS: TEE assisted well in inserting the system in all patients. The correct placement of the distal end of the right heart system 1.5 cm behind the pulmonary valve was verified in 18/23 cases by TEE vs. 23/23 cases by EE. Dislocation of the devices during tilting of the heart could only be verified by EE. CONCLUSIONS: Epicardial echocardiography is a useful, innovative method for monitoring the correct placement of the new intracardial biventricular assist device during beating-heart surgery.

Coronary Artery Bypass↗

Comparison of ultrasonic scalpel versus argon-beam and conventional electrocautery for internal thoracic artery dissection.

BACKGROUND: We used an ultrasonic scalpel (USS) and an argon beam coagulator (ABC) to test their effectiveness and feasibility in comparison to conventional electrocautery for Internal Thoracic Artery (ITA) takedown, time for takedown, number of clips, thermal impact, along with morphological integrity assessed by histology. PATIENTS AND METHODS: Ninety-three patients undergoing elective coronary bypass surgery were prospectively randomized into three groups. In thirty-one patients, either an ultrasonic scalpel (USS, group A), an argon-beam coagulator (ABC, group B) or conventional electrocautery (CEC, group C) was used for ITA harvesting. RESULTS: Harvest times for ITA takedown using CEC (16.7 +/- 6 min) was significantly faster compared to ABC (21.6 +/- 8.1 min; p = 0.02) and USS (24.1 +/- 8.1 min; p < 0.001). There was no significant difference comparing harvest times of USS and ABC (p = 0.1). The number of hemostatic clips used was significantly lower when using USS (5.5 +/- 4.6 clips) compared to both CEC (16.6 +/- 6.2 clips; p < 0.001) and ABC (20.4 +/- 6.5 clips; p < 0.001) and significantly lower using CEC compared to ABC (p < 0.007). There were no significant differences in bleeding points within the tissue bed among the groups (ABC 11/31 patients, CEC 11/31 patients and USS 12/31 patients). CONCLUSION: This study demonstrates that dissection of the ITA pedicle can be safely done with USS, ABC, and CEC. However, USS is associated with less hemostatic clip demand but prolonged harvest time compared it to ABC and CEC; histological assessment revealed no significant difference when comparing groups and equipment used. A variety in design of the hooks may probably ease ultracision practicability.

Aged↗

A new intracardiac microaxial pump: first results of a multicenter study.

As coronary artery bypass grafting (CABG) surgery in the beating heart technique is progressing, new devices have been developed to overcome hemodynamic instabilities while tilting the heart for exposure of back wall vessels. A new device for in heart biventricular intracorporeal circulation was applied in 42 patients undergoing CABG surgery (Group 1). The control group consisted of 38 patients operated on using a conventional cardiopulmonary bypass setup (Group 2). The study protocol of the prospective, randomized multicenter study was approved by the local ethics committees. Patients were included following inclusion criteria and patient informed consent. Mean age, procedure time, mean arterial pressure (MAP), and hemolysis by means of plasma free hemoglobin (fHb) were assessed preoperatively, perioperatively, on postoperative Days 1 to 3, at discharge, and at a 3 month follow-up. The mean age was 62.1 (range 59-74) years (Group 1), 62.7 (range 48-72) years (Group 2); procedure time was 112 min +/- 31.9 min (Group 1), 137.4 min +/- 36.2 min (Group 2); and 2.3 +/- 0.6 (Group 1), 2.2 +/- 0.7 (Group 2), vessels were revascularized. The flow on pump was 3.7 (2.5/4.4) L/min (Group 1), 4.9 (3.6/6.2) L/min (Group 2) which resulted in a MAP of 69.8 (4.0/143) mm Hg (Group 1), 58.3 (5.3/94) mm Hg while assessing the vessels of the back wall. Hemolysis defined by fHB was lower than 20 mg/dl at all times pre- and postoperatively. Intraoperative maximum values were up to 100 mg/dl in 4 patients (2 in Group 1 and 2 in Group 2). Body mass index was 26.4 +/- 2.6 (Group 1), 27.9 +/- 3.2. New York Heart Association Class was II to III in both groups. There were no pump related life threatening or severe adverse events. Beating heart procedures with ICC can be reliably and safely achieved. As the device is easy to use, it may deserve a more widespread use in the future.

Aged↗

[Patient-adapted valve selection: biological vs. mechanical heart valve replacement in aortic valve diseases].

Since the first aortic valve replacement performed by Harken in 1960, the operation of aortic valve disease by replacing the native valve with a heart valve prosthesis has become one of the most frequently performed procedures in cardiac surgery. For valve replacement there are biological (xenografts and homografts) and mechanical heart valve prostheses available. When choosing the most suitable prosthesis the limited durability of a biological prosthesis and the risks of lifelong anticoagulation for a mechanical prosthesis have to be balanced. In this article the indication for operation of aortic valve stenosis and aortic regurgitation are discussed first. Based on the literature of the last 2 years the advantages and disadvantages of mechanical and biological heart valve prostheses (xenograft, homograft and ROSS procedure) are discussed. In addition rarely used techniques like aortic valve reconstruction are presented. Due to the fact that a biological prosthesis has a durability of 12-15 years and the risk of bleeding complications under anticoagulation grows with increasing age, the choice of a biological prosthesis can be recommended from the age of 65 years. Results of long-term studies at to whether this limit can be diminished by using a stentless biological prosthesis have to be awaited.

Aged↗

Primary left-atrial leiomyosarcoma.

A patient rapidly developing right heart failure due to a left-atrial leiomyosarcoma was admitted for surgery. A large tumor, originating in the left atrium and extending into both pulmonary veins, was removed. Histology showed an unusual epitheloid appearance of many cells with occasional mitoses and a strong immunexpression to desmin and actin. Six months later heart failure developed again: computer tomography demonstrated regrowth of the tumor in the left atrium with invasion of the mediastinum and the para-aortal lymph nodes. The patient died shortly after.

Aged↗