PubMed Health⌕ Search

Biomedical subjects

S Bullich

Publications and source records attributed to S Bullich.

3 recordsLinked to original sources

Study of the point spread function (PSF) for 123I SPECT imaging using Monte Carlo simulation.

The iterative reconstruction algorithms employed in brain single-photon emission computed tomography (SPECT) allow some quantitative parameters of the image to be improved. These algorithms require accurate modelling of the so-called point spread function (PSF). Nowadays, most in vivo neurotransmitter SPECT studies employ pharmaceuticals radiolabelled with 123I. In addition to an intense line at 159 keV, the decay scheme of this radioisotope includes some higher energy gammas which may have a non-negligible contribution to the PSF. The aim of this work is to study this contribution for two low-energy high-resolution collimator configurations, namely, the parallel and the fan beam. The transport of radiation through the material system is simulated with the Monte Carlo code PENELOPE. We have developed a main program that deals with the intricacies associated with tracking photon trajectories through the geometry of the collimator and detection systems. The simulated PSFs are partly validated with a set of experimental measurements that use the 511 keV annihilation photons emitted by a 18F source. Sensitivity and spatial resolution have been studied, showing that a significant fraction of the detection events in the energy window centred at 159 keV (up to approximately 49% for the parallel collimator) are originated by higher energy gamma rays, which contribute to the spatial profile of the PSF mostly outside the 'geometrical' region dominated by the low-energy photons. Therefore, these high-energy counts are to be considered as noise, a fact that should be taken into account when modelling PSFs for reconstruction algorithms. We also show that the fan beam collimator gives higher signal-to-noise ratios than the parallel collimator for all the source positions analysed.

Fluorine Radioisotopes↗

Blood cyclosporine C0 and C2 concentrations and cytomegalovirus infections following lung transplantation.

The aim of this study was to determine whether cyclosporine levels predose (C0) and at two hours postdose (C2) were higher among patients presenting with cytomegalovirus (CMV) infection or disease. Between days 40 and 365 posttransplantation serial C0 and C2 levels were measured in 15 lung transplant recipients. Nine developed 13 episodes of CMV infection or disease. Both C0 and C2 levels were higher during CMV infection or disease episodes. Eleven of the 13 CMV episodes (84%) displayed C0 >220 ng/mL and none had C0 <200 ng/mL. For C2, 11 of 13 CMV episodes (84%) showed C2 >1200 ng/mL and none had C2 <1000 ng/mL. Among determinations that did not coincide with a CMV episode, 7 of 21 (33%) showed C0 >220 and 9 of 21 (42%) showed C2 >1200, respectively (P<.05). In conclusion, cyclosporine blood levels are higher among patients presenting with CMV infection or disease.

Adult↗

Dynamic model of the left ventricle for use in simulation of myocardial perfusion SPECT and gated SPECT.

Simulation is a useful tool in cardiac SPECT to assess quantification algorithms. However, simple equation-based models are limited in their ability to simulate realistic heart motion and perfusion. We present a numerical dynamic model of the left ventricle, which allows us to simulate normal and anomalous cardiac cycles, as well as perfusion defects. Bicubic splines were fitted to a number of control points to represent endocardial and epicardial surfaces of the left ventricle. A transformation from each point on the surface to a template of activity was made to represent the myocardial perfusion. Geometry-based and patient-based simulations were performed to illustrate this model. Geometry-based simulations modeled (1) a normal patient, (2) a well-perfused patient with abnormal regional function, (3) an ischaemic patient with abnormal regional function, and (4) a patient study including tracer kinetics. Patient-based simulation consisted of a left ventricle including a realistic shape and motion obtained from a magnetic resonance study. We conclude that this model has the potential to study the influence of several physical parameters and the left ventricle contraction in myocardial perfusion SPECT and gated-SPECT studies.

Algorithms↗