PubMed Health⌕ Search

Biomedical subjects

S C Henderson

Publications and source records attributed to S C Henderson.

38 records · Page 3Linked to original sources

Prostacyclin production by blood-contacting surfaces of endothelialized vascular prostheses.

This study examines prostacyclin production by blood-contacting surfaces within woven vascular prostheses of polydioxanone (PDS), polyglactin 910 (PG910), or Dacron interposed into rabbit infrarenal aortas. Grafts and normal aortic segments were explanted after 1, 3, and 6 months for pulsatile perfusion with Medium-199 for 60 minutes. Aliquots were removed serially for 6-keto-PGF1 alpha assay. After 30 minutes sodium arachidonate (10 micrograms/ml) was added. Specimens were studied by light microscopy, SEM and TEM. Patency in all three groups exceeded 90%. All three showed re-endothelialization at one month. Normal aorta produced low basal 6-keto-PGF1 alpha with a marked evanescent post arachidonate increase. Dacron did not differ from normal aorta. PG910 and PDS both produced significantly less 6-keto-PGF1 alpha post arachidonate at one month but both increased to normal by three months.

6-Ketoprostaglandin F1 alpha↗

The validity of canine platelet aggregometry in predicting vascular graft patency.

Several laboratories have found canine platelet aggregometry predictive of thrombotic potential in vascular grafts. Adenosine diphosphate (ADP) is a frequently used agonist, often at unspecified or differing concentrations. This study was designed to evaluate the predictive value of ADP-induced platelet aggregometry and the validity of the methodology. Platelet aggregometry in response to 2 x 10(-5) M ADP was assayed in 70 dogs. Twenty-six percent were aggregators, 51% were non-aggregators, and 20% were indeterminant. All dogs were then treated with aspirin and dipyridamole. Vascular prostheses were implanted bilaterally (aorto-iliac) and anti-platelet therapy continued for two weeks. Dose-response to ADP was studied at three concentrations in 20 dogs. At 2 x 10(-5) 1/20 aggregated, at 4 x 10(-5) 3/19 aggregated and at 2 x 10(-4) 15/20 aggregated. Time between samples and study was evaluated in 11 dogs, with 2/11 changing from non-aggregator to aggregator at two or three hours. Daily reproducibility was studied in 70 dogs, 14 of which changed aggregation status between days. Patency was 58/68 (85%) for non-aggregators, 23/34 (68%) for aggregators (p = 0.038). Platelet aggregometry has significant predictive value for graft patency but methodology must be specified and standardized.

Adenosine Diphosphate↗