PubMed HealthSearch

Biomedical subjects

S C Port

Publications and source records attributed to S C Port.

11 recordsLinked to original sources

Left ventricular volume calculation using a count-based ratio method applied to first-pass radionuclide angiography.

Most count-based radionuclide methods for calculating left ventricular volume rely on measurement of radioactivity in a peripheral blood sample and a measurement of ventricle to collimator distance. We have developed a method which requires neither a blood sample nor a distance measurement and which is applicable to first-pass radionuclide angiography. The parameters used to calculate volume are the area of pixel, the total counts in the left ventricle and the maximum pixel count. The equation was used to calculate the volumes in 50 patients who had both resting first-pass radionuclide angiography (25 patients with a single crystal and 25 patients with a multicrystal camera) and contrast ventriculography on the same day. Correlation coefficients for end-diastolic and end-systolic volumes showed r ranging 0.93-0.98 and standard error of estimate ranging 23-35 ml for end-diastolic volume (14%-17% of mean end-diastolic volume) and 16-23 ml for end-systolic volume (18%-21% of mean end-systolic volume). Image processing software for extracting the needed values is generally available on most commercial nuclear medicine imaging systems and the additional time for the calculations is short. Although the theory is based on multiple assumptions, the volume calculation appears to be reasonably accurate and clinically applicable.

Adult

Long-term prognostic value of a normal dipyridamole thallium-201 perfusion scan.

In a 4-year period, 84 patients who were referred for a dipyridamole thallium-201 stress test to rule out significant coronary artery disease had normal scans. A dipyridamole study was recommended instead of exercise because of arthritis, severe obesity, peripheral vascular disease, pulmonary disease, other chronic illnesses, or combinations of these problems. All patients had three-view (i.e., anterior, shallow left anterior oblique, and steep left anterior oblique) planar thallium-201 imaging 10 minutes and 3.5 hours after administration of 0.6 mg/kg of intravenous dipyridamole. The patients were followed for 42 +/- 13 (range 1-58) months to document the cardiac event rate. Of the 84 patients with normal results, 14 died during the follow-up period from noncardiac causes. Three other patients died 29-51 months after the test due to an acute myocardial infarction, a probable acute myocardial infarction, and sudden cardiac death, respectively. Of the survivors, 5 suffered an acute myocardial infarction 28-50 months after the dipyridamole thallium scan and 1 had coronary artery bypass grafting due to increasing angina pectoris 58 months after the scan (overall cardiac event rate of 0.4% per year). Of the remaining 61 patients, 39 (64%) were asymptomatic, 20 (33%) had the same symptoms they had at the time of testing without significant deterioration, while 2 patients (3%) had deterioration of their chest pains but no cardiac complication. Thus, in this group of patients, a normal dipyridamole thallium-201 perfusion scan predicted a good cardiovascular outcome for at least 24 months following the test.

Adult

Coronary vasodilator reserve. Comparison of the effects of papaverine and adenosine on coronary flow, ventricular function, and myocardial metabolism.

To evaluate coronary flow reserve during cardiac catheterization, intracoronary adenosine and papaverine have been used in the clinical setting. Although papaverine maximizes coronary blood flow, it induces several toxic side effects that reduce its desirability as a coronary dilator. This investigation was designed to compare the subselective intracoronary administration of papaverine with that of adenosine in an animal model. In dogs (n = 34), we studied the effects of each agent on hemodynamics, regional myocardial blood flow, contractility (sonomicrometric and echocardiographic), metabolism (coronary arterial and venous lactate and tissue high-energy phosphates), and electrocardiographic (ST and QT intervals) parameters. Barbiturate and morphine anesthesia/analgesia was induced, and a left thoracotomy was performed. An arterial shunt was created from the left carotid artery to the left anterior descending coronary artery. Two separate groups were studied: group 1 (n = 16) for regional myocardial blood flow and mechanical function and group 2 (n = 18) for biochemical measurements. Adenosine (67 +/- 2 micrograms/min) or papaverine (6 +/- 1 mg/min) was infused into the coronary shunt at a rate of 0.5 + 0.1 ml/min for a maximum duration of 3.5 minutes. Regional myocardial blood flows were determined at control (predrug) and maximal coronary flow using radiolabeled microspheres. All hemodynamic, wall motion, biochemical, and electrocardiographic parameters were also measured at these times. Both drugs produced comparable increases in total and regional coronary blood flows (adenosine, 1.21 +/- 0.15 to 4.83 +/- 0.36 ml/min/g; papaverine, 1.21 +/- 0.05 to 4.89 +/- 0.28 ml/min/g) upon infusion into the left anterior descending coronary artery. Papaverine produced significant (p less than 0.05) changes in subendocardial ST segment electrocardiogram (-2.5 mm), QT prolongation (8 +/- 2%), myocardial creatine phosphate (47% decrease), and coronary sinus serum lactate (277% increase) compared with control. In addition, intracoronary papaverine induced an abnormal contractile pattern. No significant changes in any of these parameters (i.e., ST segment, QT prolongation, myocardial creatine phosphate level, or lactate level) were observed with intracoronary adenosine infusions. We conclude that intracoronary adenosine is comparable to papaverine for maximizing coronary blood flow without the deleterious properties observed with intracoronary papaverine.

Adenosine

Technically suboptimal first-pass radionuclide angiographic studies.

First-pass radionuclide angiography (FPRNA) has proven to correctly assess left ventricular function, however, technical difficulties do occur. One hundred and thirty one patients had contrast angiography and resting radionuclide angiography within 24 h. Of the 131 patients, 86 (66%) had adequate studies and 45 (34%) were technically suboptimal studies. In the latter group, low counts affected the quality of the images but did not change the left ventricular ejection fraction (LVEF) or regional wall motion (RWM) scores. Patients with high background activity showed overestimation of LVEF, however, by using a formula that was derived from the linear regression the LVEF could be calculated accurately in most cases. Multiple technical problems were noted in 14 patients in whom the best correlation was between contrast LVEF and background uncorrected LVEF from FPRNA (r = 0.87). In the latter group, FPRNA showed overestimation of RWM in 8 patients (57%), mainly in the inferior wall. We conclude that for most technically compromised first-pass radionuclide angiographic data, accurate LVEF values can be achieved but errors in regional wall motion interpretation will occur, especially when multiple technical problems exist.

Female

Left ventricular volume calculation using a count-based ratio method applied to multigated radionuclide angiography.

The purpose of this study was to investigate the accuracy of a new count-proportional method for the measurement of left ventricular volume when applied to gated equilibrium blood-pool imaging. An equation is developed that relates total chamber volume, Vt, to the area of a pixel (M) and the ratio (R) of total counts within the chamber to the counts within the hottest pixel in the chamber such that Vt = 1.38 M3R3/2. The value of M is a constant for the particular scintillation camera-collimator system and R is obtained from observed count rates. All calculated volumes were compared to volumes measured using biplane contrast ventriculography. In 25 patients, the method for ventricular volumes gave an r of 0.95 and an s.e.e. of 23 ml [Volume (nuclear) = 0.94 Volume (cath) + 1.3]. Endsystolic volume was best calculated from end-diastolic volume and ejection fraction. Manual regions of interest were more accurate than automated regions of interest. This method appears to be as accurate as more complex approaches and has the advantage of not requiring attenuation correction or blood sampling.

Angiography

Radionuclide angiography in congenitally corrected transposition of the great vessels in an adult.

The case of a 34-yr-old man with congenitally corrected transposition of the great vessels is described. Both first-pass and equilibrium radionuclide angiographic data were acquired and demonstrate the value of both studies in delineating the ventricular inversion and the transposed great vessels that are characteristic of this disorder. In addition to the anatomic information, the ejection fractions of the venous and systemic ventricles at rest and during exercise, the lack of any left to right shunt, and the presence of systemic A-V valve insufficiency can all be obtained from the scintigraphic data.

Adult

High count rate first-pass radionuclide angiography using a digital gamma camera.

In this study, first-pass radionuclide angiography (FPRNA) was performed using a digital single-crystal gamma camera. Twenty-nine men and six women (ages 43-80, mean 61 yr) underwent FPRNA in the supine position immediately prior to cardiac catheterization. Total counts/sec in the whole field-of-view in the right ventricular phase were 150,352 +/- 26,006. Background uncorrected counts in the representative cycle were 7,651 +/- 2,527 at end-diastolie and 4,904 +/- 2,314 at end-systolie. A linear correlation between FPRNA left ventricular (LV) ejection fraction and contrast LV ejection fraction gave an r = 0.95 with an s.e.e. of 0.05. Analyses of intra- and interobserver variability gave r = 0.99 and 0.98 and an s.e.e. of 0.02 and 0.03, respectively. Spearman-Rank correlation coefficients between FPRNA and contrast angiographic wall-motion scores were greater than 0.8 for all walls, while sensitivity/specificity were 0.86/0.90, 0.76/1.00, 0.76/1.00 for anterior, apical, and inferior wall-motion abnormalities, respectively. We conclude that satisfactory counting statistics for FPRNA can be obtained with a digital gamma camera, and that accurate and reproducible measurements of global and regional left ventricular function can be obtained with this technique.

Adult

Background correction in first-pass radionuclide angiography: comparison of several approaches.

This study was designed to test the comparative accuracy of several commonly used background correction techniques in first-pass radionuclide angiography (FPRNA). Thirty patients underwent FPRNA and single plane contrast angiography (CA) within 1 hr of each other. The left ventricular ejection fractions (LVEF) calculated from the different background subtraction approaches to FPRNA were compared to the CA LVEF. When applied to a representative cycle, a horseshoe-shaped background region of interest (BKROI) underestimated LVEF (p less than 0.005, r = 0.91, s.e.e. = 0.06) while a ring shaped BKROI adjusted at end-systole for aortic valve motion insignificantly overestimated LVEF (p = NS, r = 0.91, s.e.e. = 0.07). A lung background approach applied to a representative cycle gave the best correlation with CA (p = NS, r = 0.96, s.e.e. = 0.04). Without using a representative cycle, time-activity curves from a horseshoe-shaped BKROI and the LV ROI were created and the LV curve was normalized to the peak counts in the BKROI curve. LVEF calculated from the normalized curve correlated favorably with CA LVEF (p = NS, r = 0.91, s.e.e. = 0.08). The influence of some recently described improvements in representative cycle generation are also documented.

Aged

Arm vein uptake of thallium-201 during exercise: incidence and clinical significance.

We prospectively analyzed several clinical and technical variables that might be associated with arm vein uptake of 201Tl during stress thallium scintigraphy in 63 patients. The influence of site (medial antecubital vs. other vein) and technique (with or without a 15-cc saline flush) were examined. Arm vein uptake was not seen after medial antecubital injections except in one case injected through a 24-hr-old indwelling catheter. Arm vein uptake was seen in 24/45 (53%) of cases injected into veins other than the medial antecubital. A saline flush did not reduce the incidence of arm uptake. In patients with normal myocardial studies, those with positive arm uptake had 33% lower net myocardial counts on the postexercise images (p = 0.00008) and 20% lower net myocardial counts on the delayed images (p = 0.04). Myocardial washout of thallium was significantly (p = 0.009) slower in those with arm uptake.

Adult

Assessment of single vessel coronary artery disease: results of exercise electrocardiography, thallium-201 myocardial perfusion imaging and radionuclide angiography.

The sensitivity of the commonly used stress tests for the diagnosis of coronary artery disease was analyzed in 46 patients with significant occlusion (greater than or equal to 70% luminal diameter obstruction) of only one major coronary artery and no prior myocardial infarction. In all patients, thallium-201 perfusion imaging (both planar and seven-pinhole tomographic) and 12 lead electrocardiography were performed during the same graded treadmill exercise test and radionuclide angiography was performed during upright bicycle exercise. Exercise rate-pressure (double) product was 22,307 +/- 6,750 on the treadmill compared with 22,995 +/- 5,622 on the bicycle (p = NS). Exercise electrocardiograms were unequivocally abnormal in 24 patients (52%). Qualitative planar thallium images were abnormal in 42 patients (91%). Quantitative analysis of the tomographic thallium images were abnormal in 41 patients (89%). An exercise ejection fraction of less than 0.56 or a new wall motion abnormality was seen in 30 patients (65%). Results were similar for the right (n = 11) and left anterior descending (n = 28) coronary arteries while all tests but the planar thallium imaging showed a lower sensitivity for isolated circumflex artery disease (n = 7). The specificity of the tests was 72, 83, 89 and 72% for electrocardiography, planar thallium imaging, tomographic thallium imaging and radionuclide angiography, respectively. The results suggest that exercise thallium-201 perfusion imaging is the most sensitive noninvasive stress test for the diagnosis of single vessel coronary artery disease.

Adult