Imaging anisotropic and viscous properties of breast tissue by magnetic resonance-elastography.

MR-elastography is a new technique for assessing the viscoelastic properties of tissue. One current focus of elastography is the provision of new physical parameters for improving the specificity in breast cancer diagnosis. This analysis describes a technique to extend the reconstruction to anisotropic elastic properties in terms of a so-called transversely isotropic model. Viscosity is treated as being isotropic. The particular model chosen for the anisotropy is appealing because it is capable of describing elastic shear anisotropy of parallel fibers. The dependence of the reconstruction on the particular choice of Poisson's ratio is eliminated by extracting the compressional displacement contribution using the Helmholtz-Hodge decomposition. Results are presented for simulations, a polyvinyl alcohol breast phantom, excised beef muscle, and measurements in two patients with breast lesions (invasive ductal carcinoma and fibroadenoma). The results show enhanced anisotropic and viscous properties inside the lesions and an indication for preferred fiber orientation.

Algorithms↗

Measuring of viscoelastic properties of homogeneous soft solid using transient elastography: an inverse problem approach.

Two main questions are at the center of this paper. The first one concerns the choice of a rheological model in the frequency range of transient elastography, sonoelasticity or NMR elastography for soft solids (20-1000 Hz). Transient elastography experiments based on plane shear waves that propagate in an Agar-gelatin phantom or in bovine muscles enable one to quantify their viscoelastic properties. The comparison of these experimental results to the prediction of the two simplest rheological models indicate clearly that Voigt's model is the better. The second question studied in the paper deals with the feasibility of quantitative viscosity mapping using inverse problem algorithm. In the ideal situation where plane shear waves propagate in a sample, a simple inverse problem based on the Helmholtz equation correctly retrieves both elasticity and viscosity. In a more realistic situation with nonplane shear waves, this simple approach fails. Nevertheless, it is shown that quantitative viscosity mapping is still possible if one uses an appropriate inverse problem that fully takes into account diffraction in solids.

Algorithms↗

Observation of shock transverse waves in elastic media.

We report the first experimental observation of a shock transverse wave propagating in an elastic medium. This observation was possible because the propagation medium, a soft solid, allows one to reach a very high Mach number. In this extreme configuration, the shock formation is observed over a distance of less than a few wavelengths, thanks to a prototype of an ultrafast scanner (that acquires 5000 frames per second). A comparison of these new experimental data with theoretical predictions, based on a modified Burger's equation, shows good agreement.

Journal Article↗

In vivo breast tumor detection using transient elastography.

This paper presents first in vivo experiments for breast tumor detection using transient elastography. This technique has been developed for detection and quantitative mapping of hard lesions in soft tissues. It consists in following the propagation inside soft tissues of very low-frequency shear waves (approximately 60 Hz) generated by a vibrating system located at the body surface. Because transient shear waves propagate through the medium in less than 0.1 s, the shear propagation imaging is performed with an ultrafast echographic scanner able to reach frame rates up to 6000 Hz. The local shear wave speed is directly linked to the local shear Young's modulus of the medium. The shear elasticity map of the medium can then be computed using an inversion algorithm. In vivo experiments were conducted on 15 women who had palpable breast lesions. For clinical adaptability reasons, shear waves were generated by the surface of the ultrasound (US) imaging transducer itself, which was linked to a mechanical vibrator. Our preliminary in vivo results demonstrate the clinical applicability of the transient elastography technique for breast lesion detection.

Adenocarcinoma↗

Measurement of elastic nonlinearity of soft solid with transient elastography.

Transient elastography is a powerful tool to measure the speed of low-frequency shear waves in soft tissues and thus to determine the second-order elastic modulus mu (or the Young's modulus E). In this paper, it is shown how transient elastography can also achieve the measurement of the nonlinear third-order elastic moduli of an Agar-gelatin-based phantom. This method requires speed measurements of polarized elastic waves measured in a statically stressed isotropic medium. A static uniaxial stress induces a hexagonal anisotropy (transverse isotropy) in solids. In the special case of uniaxially stressed isotropic media, the anisotropy is not caused by linear elastic coefficients but by the third-order nonlinear elastic constants, and the medium recovers its isotropic properties as soon as the uniaxial stress disappears. It has already been shown how transient elastography can measure the elastic (second-order) moduli in a media with transverse isotropy such as muscles. Consequently this method, based on the measurement of the speed variations of a low-frequency (50-Hz) polarized shear strain waves as a function of the applied stress, allows one to measure the Landau moduli A, B, C that completely describe the third-order nonlinearity. The several orders of magnitude found among these three constants can be justified from the theoretical expression of the internal energy.

Elasticity↗

A solution to diffraction biases in sonoelasticity: the acoustic impulse technique.

Several methods have been proposed to estimate the viscoelastic properties of soft biological tissues using forced low-frequency vibrations (10-500 Hz). Those methods are based on the measurement of phase velocity of the shear waves (approximately 5 m/s). It is shown in this article that the measurements of velocity as well as attenuation are subjected to biases. These biases are related to reflected waves created at boundaries, to the nonnegligible size of the piston source which causes diffraction effects and to the influence of a low-frequency compressional wave. Indeed, a theoretical analysis of the field radiated by a point source explains how mechanical vibrations of a piston generate a shear wave with a longitudinal component and how this component can interfere with a low-frequency compressional wave. However, by using a low-frequency transient excitation, these biases can be avoided. Then the precise numerical values of elasticity and viscosity can be deduced. Experiments in phantoms and beef muscles are shown. Moreover, a relative hardness imaging of a phantom composed of two media with different elasticities is presented.

Acoustics↗

Time-resolved pulsed elastography with ultrafast ultrasonic imaging.

In this paper, a new elastographic method is proposed. Using this method, the propagation of a low-frequency transient shear wave can be imaged by means of an ultrafast imaging system (up to 10,000 frames/s) that we have developed. Ultrafast ultrasonic imaging is obtained with a linear array of transducers (3.5 MHz) connected to electronics that have 64 channels sampled at 30 MHz and 128 Kbytes for storing the backscattered signals. Displacements are measured using cross-correlation of the ultrasonic signals. Movies of the low central frequency (200 Hz) shear wave propagation through homogeneous and heterogeneous phantoms have been obtained with 1,000 and 2,000 frames per second.

Elasticity↗