The value of different screening tests in predicting prostate biopsy outcome in screening for prostate cancer data from a multicenter study (ERSPC).

BACKGROUND: Although serum PSA testing is widely used as a screening test for prostate cancer (PC), it is known that it is not specific for PC. The study described here focuses on the value of screening tests next to PSA in identifying men with an elevated risk of having PC and the differences between three centers of the European Randomised study of Screening for Prostate Cancer (ERSPC). METHODS: The study population consists of 2,483 men with a PSA > or =4.0 ng/ml, all biopsied. We assessed data on age, serum PSA level at initial and repeat screening, prostate volume, number of positive DRE and TRUS findings, number of previous negative biopsies, and PPV of the three centers and overall. Using logistic regression analysis, predictors for biopsy outcome at repeat screening in men with a PSA value > or =4.0 ng/ml were determined on the complete dataset and per center. RESULTS: In 2,483 men biopsied, 665 cancers were detected (PPV = 26.8%). Data show that all predictors except prostate volume loose their predictive value in men previously biopsied. In men not previously biopsied, the predictive value of DRE and TRUS vary considerably among the three centers. CONCLUSIONS: Looking at the differences in the predictive value of screening tests in three "comparable" centers, generasibility is not as straightforward as it seems. Using a nomogram for predictive purposes developed elsewhere will require a thorough knowledge of the patient population of which it is derived, and one should interpret its results with a critical mind.

Aged↗

Association of FOBT-assessed faecal Hb content with colonic lesions detected in the Florence screening programme.

We assessed the correlation between quantitative results of immunological faecal occult blood testing (I-FOBT) and colonic lesions (191 colorectal cancers, 890 adenomas) detected at colonoscopy in 2597 FOBT+ (cutoff 100 ng ml(-1) Hb) subjects. At univariate analysis, a higher average faecal Hb content was significantly associated with male gender (P=0.003), age (P=0.02), and colonoscopy findings (P=0.000). Among adenomas, higher faecal Hb content was significantly associated with size (P=0.0000), presence of severe dysplasia (P=0.0001), presence of villous component (P=0.0002), and location in the left colon (P=0.003). At multivariate analysis adjusting for potential confounders, age (P=0.03), size (P=0.0000), and location in the left colon (P=0.0005) were confirmed as having an independent association with higher faecal Hb content. Immunological FOBT is confirmed to be a specific screening test to detect cancer and adenoma, with a low positivity rate (3.7%) and a high positive predictive value (41.5%). Faecal Hb content is significantly higher for those lesions (cancer and high-risk adenomas) screening is aimed at detecting.

Aged↗

Minority report - false negative breast assessment in women recalled for suspicious screening mammography: imaging and pathological features, and associated delay in diagnosis.

AIM: We studied imaging, pathology and diagnostic aspects of false negative assessment (FNA) in women recalled for suspicious screening mammography. METHOD: Subjects were women aged 50-69 years undergoing biennial screening mammography within the Florence District screening programme from January 1992-December 2001 (339,953 consecutive screens). We identified all cancers occurring in women recalled to assessment and ascertained, and reviewed, all cases considered as negative on assessment and subsequently diagnosed with breast cancer. We compared imaging features, tumour histology and stage, and diagnostic testing on assessment for all women with cancer, and presentation and length of delay in women falsely negative on assessment. RESULTS: Eleven thousand six hundred and twenty four women were recalled to diagnostic assessment (recall rate = 3.4%) predominantly for suspicious mammography (9,216 positive screens). Breast cancer was missed in 57 cases: a FNA rate of 0.50% (0.37-0.62%) and comprising 4.1% (3.0-5.1%) of cancers occurring in women recalled after a positive screen. Two types of abnormalities were significantly more frequent in FNA cases than cancers detected at assessment: mass with regular borders (21.1 vs. 5.6%, p = 10(-5)), and asymmetrical density (22.8 vs. 5.4%, p = 10(-5)). On review 56% of FNAs were benign or probably benign BI-RADS categories. FNA occurred in 1.4% of early recalls and in 0.4% of initial assessment (p=0.0001). Significantly fewer tests were performed when assessing missed cancers than detected cancers with the most significant difference noted for FNAC (29.8 vs. 96.0%, p=10(-6)); mammography as the only evaluation on assessment was more frequent in missed cancers (31.5% vs 0.2%, p = 10(-6)). The 57 missed cases were subsequently diagnosed at early recall (2 cases), next biennial screen (11 cases), or as interval breast cancers (44 cases) with a mean delay in diagnosis of 628 days. Tumour histology, size and nodal status did not significantly differ between cancers missed and cancers diagnosed on assessment. CONCLUSION: False negatives on assessment represent a minority group in whom screening has failed. They might be reduced by adopting a more intensive diagnostic approach to assessment. Although there was no evidence of a worse prognosis in cancers missed at assessment, the delay in diagnosis is substantial and may impact long-term outcomes.

Aged↗

Analysis of the results of a proficiency test in screening mammography at the CSPO of Florence: review of 705 tests.

PURPOSE: The aim of this study was to evaluate the performance of a sample of Italian radiologists undergoing a proficiency test of screening mammography. MATERIALS AND METHODS: We retrospectively analysed the results of 705 tests (537 first tests, 168 repeat tests) taken during 1997-2005 by 537 Italian radiologists. The test, consisting of 17 screen-detected cancer cases and 133 negative controls, was validated by a panel of expert readers defining a minimum standard as to sensitivity for cancer and recall rate of negative controls. Success rates were assessed as a function of previous experience in mammography (years of experience, total mammograms read, mammograms read in the last year). RESULTS: A total of 176 radiologists successfully passed the test at their first attempt (32.7%). Success correlated with experience, measured in terms of years of experience (5-year cutoff: chi(2) for trend=4.17, p=0.04), total mammograms read (chi(2) for trend =11.8, p=0.002) or mammograms read in the last year (chi(2) for trend=6.27, p=0.04). Training improves performance at repeat testing: after a first negative attempt, a second attempt was successful in 50.6% of cases (74/146) and a third in 68.1% (15/22). CONCLUSIONS: A substantial proportion of Italian radiologists taking the test showed limited proficiency in screening mammography. This finding is consistent with several reports of poor performance of service screening compared with reference standards. As expected, test performance is associated with experience, suggesting that the current policy of employing non-dedicated, untrained, general radiologists in screening should be reconsidered. Test performance improves with training (courses, consultation of teaching atlases). Several screening programmes in Italy have been implemented without prior adequate radiologist training. Radiologist training needs to be considered a priority, at least in those screening programmes that are still to be implemented in one third of the country.

Aged↗

Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

PURPOSE: The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. MATERIALS AND METHODS: We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. RESULTS: Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups <40, 40-49, 50-59 and >59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. CONCLUSIONS: The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

Adult↗

Positive predictive value of breast fine needle aspiration cytology (FNAC) in combination with clinical and imaging findings: a series of 2334 subjects with abnormal cytology.

We calculate the positive predictive value (PPV) of abnormal (C3-5) FNAC, alone and in combination with clinical and imaging findings, based on a consecutive series of 2,334 subjects. The PPV of a C3, C4 or C5 report is 55.0%, 95.9% and 99.4%, respectively. C5 Cytology is highly predictive of malignancy (PPV=99.4-99.7%) except where imaging is negative or benign. When C4 cytology is associated with suspicious findings on imaging and/or palpation, its PPV increases to 98.5-98.7%. C3 is the least predictive of malignancy and even when associated with suspicious findings on imaging and/or palpation its PPV is 83.3% - C3 FNAC should therefore prompt pre-operative core biopsy. These data indicate that FNAB is still a useful test in breast diagnosis, and it may assist clinical decision-making as far as whether patients should progress to surgical management or should have further core biopsy before planning surgery.

Biopsy, Fine-Needle↗

Computer-aided detection (CAD) of cancers detected on double reading by one reader only.

We evaluated the role of computer-aided detection (CAD) in cancers undergoing double reading and detected by one reader only. A series of 33 cancers, originally missed by the first reader and detected by the second reader, and 75 negative controls were processed to assess CAD sensitivity, and was read by the six radiologists who originally missed the cancers with the help of CAD printouts. CAD case-based sensitivity, specificity and positive predictive value were 51.5%, 18.6% and 21.7%, respectively. Average sensitivity of all radiologists in all cancers in the series was 74.7%, being higher for CAD+ (86.2%) than for CAD- (62.5%) cancers (P<0.01). When reading cancer cases that they had originally missed, radiologists had a sensitivity of 75.8%, which was higher for CAD+ (100.0%) than for CAD- (58.3%) cancers. The average recall rate was 14.2%, the majority of recalls (45 out of 64) occurring for lesions marked by CAD. CAD may help in detecting at most half of cancers missed at a single reading but detected by a second reader.

Breast Neoplasms↗

A methodology to evaluate differential costs of full field digital as compared to conventional screen film mammography in a clinical setting.

PURPOSE: The use of full field digital mammography (FFDM) in alternative to conventional screen film mammography (SFM) in the current practice is delayed by the high costs of FFDM. The present study, performed at the Centro per lo Studio e la Prevenzione Oncologica of Florence, using both FFDM and SFM, was aimed at estimating the impact of introducing the new FFDM technique on overall mammography costs. MATERIAL AND METHODS: We estimated the differential costs of both methods, based on real expenditures, as provided by the administrative department, and on radiologists, radiographers and other staff's working time. Two different workload scenarios (5000 and 10,000 tests/year per mammography equipment) were considered. Common costs of both techniques were censored for study purpose. RESULTS: Beside a higher cost due to purchase and hire/leasing costs of equipment, FFDM implies a greater workload for radiologists (reading time almost doubled). SFM implies a greater workload for the administrative staff to run the archive and for loading/unloading films of the roller viewer, whereas no different workload has been observed for radiographers. Overall FFDM costs 24.22-26.46 for examination more than SFM for the 5000 tests scenario and 9.91-12.15 more for the 10,000 tests scenario. DISCUSSION: Although present study estimates cannot easily be generalised to any local setting, the model for cost calculation is easy to be exported to another scenario by applying different local parameters. The advantages made available by FFDM (computerised data recording, tele-transmission, tele-reporting, tele-consulting, automatic display on monitor of previous exams and use of CAD) may justify the higher cost, but a limited reduction in purchase and assistance costs could easily allow a turnover, with FFDM being more convenient than SFM even on the cost side.

Breast Neoplasms↗

Reader variability in reporting breast imaging according to BI-RADS assessment categories (the Florence experience).

The inter- and intraobserver agreement (K statistic) in reporting according to BI-RADS assessment categories was tested on 12 dedicated breast radiologists, with little prior working knowledge of BI-RADS, reading a set of 50 lesions (29 malignant, 21 benign). Intraobserver agreement (four categories: R2, R3, R4, R5) was fair (0.21-0.40), moderate (0.41-0.60), substantial (0.61-0.80) or almost perfect (>0.80) for one, two, five or four radiologists, or (six categories: R2, R3, R4a, R4b, R4c, R5) fair, moderate, substantial or almost perfect for three, three, three or three radiologists, respectively. Interobserver agreement (four categories) was fair, moderate or substantial for three, six, or three radiologists, or (six categories) slight, fair or moderate for one, six, or five radiologists. Major disagreement occurred for intermediate categories (R3=0.12, R4=0.25, R4a=0.08, R4b=0.07, R4c=0.10). We found insufficient intra- and interobserver consistency of breast radiologists in reporting BI-RADS assessment categories. Although training may improve these results, simpler alternative reporting methods (systems), focused on clinical decision-making, should be explored.

Breast Neoplasms↗

Florence-Sydney Breast Biopsy Study: sensitivity of ultrasound-guided versus freehand fine needle biopsy of palpable breast cancer.

BACKGROUND: Fine needle aspiration biopsy (FNAB) is widely used in the diagnosis of breast cancer. It is unknown whether, for palpable cancers, ultrasound-guided FNAB is more accurate than freehand FNAB, and practice varies between physicians, services and countries. METHODS: From consecutive women attending a major cancer centre in Florence, we prospectively recruited subjects who had a definitely palpable lump which was solid on ultrasound and suspicious of malignancy (n = 102). All subjects were investigated using both ultrasound-guided and freehand FNAB (one aspirate with each method). Radiologists skilled in both sampling techniques performed all clinical examinations and aspirations, and for each subject the same radiologist obtained both FNAB samples. Sequence of aspiration method was randomised. Cytological interpretation was blinded to method of sampling. Comparative sensitivity (and insufficiency) for FNAB using the two methods was calculated in all cancers (n = 97). RESULTS: Ultrasound-guided FNAB resulted in 13.6% (5-22%) less insufficient aspirates than freehand FNAB (chi2 = 7.58; p = 0.006). When insufficient aspirates are included and considered as negative, ultrasound-guided FNAB has a 14.6% (5.8-23%) or a 16.5% (7.6-25.4%) significantly better sensitivity than freehand FNAB (for cytology 3-5 positive or cytology 4-5 positive respectively). When insufficient aspirates are excluded from the analysis, ultrasound-guided FNAB has a 1.4% (-1.2 to 3.9%) or a 2.6% (-2.5 to 7.8%) higher sensitivity than freehand FNAB (for cytology 3-5 positive or cytology 4-5 positive respectively) but this difference in the sensitivity of the two methods is not statistically significant. CONCLUSION: Our data suggest that ultrasound-guided FNAB has better sensitivity than freehand FNAB in palpable breast cancer, which is predominantly an effect of a significant reduction in insufficient aspirates, but in part an effect of 'upgrading' cytological classification of cancers.

Adult↗

Categorizing breast mammographic density: intra- and interobserver reproducibility of BI-RADS density categories.

The inter- and intraobserver agreement (kappa-statistic) in reporting according to Breast Imaging Reporting and Data System (BI-RADS((R))) breast density categories was tested in 12 dedicated breast radiologists reading a digitized set of 100 two-view mammograms. Average intraobserver agreement was substantial (kappa=0.71, range 0.32-0.88) on a four-grade scale (D1/D2/D3/D4) and almost perfect (kappa=0.81, range 0.62-1.00) on a two-grade scale (D1-2/D3-4). Average interobserver agreement was moderate (kappa=0.54, range 0.02-0.77) on a four-grade scale and substantial (kappa=0.71, range 0.31-0.88) on a two-grade scale. Major disagreement was found for intermediate categories (D2=0.25, D3=0.28). Categorization of breast density according to BI-RADS is feasible and consistency is good within readers and reasonable between readers. Interobserver inconsistency does occur, and checking the adoption of proper criteria through a proficiency test and appropriate training might be useful. As inconsistency is probably due to erroneous perception of classification criteria, standard sets of reference images should be made available for training.

Breast Neoplasms↗

Second reading of screening mammograms increases cancer detection and recall rates. Results in the Florence screening programme.

OBJECTIVE: To assess double reading effectiveness in mammography screening. DESIGN: Retrospective study of 177,631 consecutive mammograms double read during 1998-2003. SETTING: The Florence screening programme, involving 11 trained radiologists. Abnormalities reported by at least one reader prompted assessment. RESULTS: The referral rate was 2.89% for the first reader, 3.15% for the second reader, and 3.59% for either reader. Of 713 total cancers detected, 43 were suspected only by the second reader (6.4% relative, 0.024% increase in absolute detection rate) and had a lower stage compared to the first reader (pTis-pT1b = 65.7 versus 52.0%): 41 were reviewed and classified (error type) as "minimal sign" in six, and "screening error" in 35 cases, or as BI-RADS 3 in one, 4a in 20, 4b in 13, and 4c in three cases. The second reading cost was 2.70 per woman examined, or 11,168 per additional cancer detected (versus 11,585 at a single reading). DISCUSSION: Second reading is effective in detecting a limited number of additional cancer cases. Tumour stage (one-third over 1 cm in diameter) and review findings (high rate of "screening errors" and BI-RADS R4b-c categories) suggest that second reading detects small "difficult cases" as well as larger cancers missed due to fatigue or loss of attention. Second reading reduces screening specificity to a minor extent, and since cancer detection at second reading seems cost-effective the procedure is recommendable in routine practice.

Aged↗

The role of arbitration of discordant reports at double reading of screening mammograms.

OBJECTIVE: To asses the effectiveness of arbitration of discordant double readings in mammography screening. DESIGN: A retrospective study of 1217 consecutive arbitrations. SETTING: A subset of discordant double readings from the Florence screening programme underwent arbitration by a third reader. RESULTS: Positive arbitration of 1217 discordant double readings prompted assessment in 476 cases (39.2%), detecting 30 cancers (6.3%). Of 741 negative arbitrations (60.8%), 311 have been followed up thus far, and two cancers (0.64%) occurred in the site previously suspected at one of the two independent readings. Arbitration had a sensitivity of 86.3% and a negative predictive value of 99.3%. Arbitration reduced the overall referral rates from 3.82% to 2.59% (relative decrease 32.1%). Due to false-negative arbitration, cancers detected per 1000 women screened would decrease from 4.58 to 4.50 (relative decrease 1.7%). For every cancer missed due to false-negative arbitration, 151 unnecessary recalls and 21,248 euro would have been saved, whereas the saved cost per screened woman due to arbitration was 1.72 euro. DISCUSSION: Arbitration of discordant double reading would substantially reduce referral rates with a limited reduction in cancer detection rate, and may be recommended as a routine procedure. Greater benefit from arbitration might be expected in the presence of high referral rates at independent double reading, a common scenario in a newly implemented service screening.

Breast Neoplasms↗

Lower protection of cytological screening for adenocarcinomas and shorter protection for younger women: the results of a case-control study in Florence.

The efficacy of cytological screening in preventing adenocarcinoma of cervix uteri as compared to squamous cell cancer has been evaluated by means of a case-control study in the province of Florence. The odds ratios of women who had a Pap test within the 3 years before the index date was 0.65 (95% confidence interval (CI) 0.26-1.64) and 0.15 (95% CI 0.07-0.31), for adenocarcinoma and squamous cancer, respectively. The duration of the protective effect was shorter in women below the age of 40 years than in older women.

Adenocarcinoma↗

Breast density as a determinant of interval cancer at mammographic screening.

The association of breast density (% of breast volume involved by fibro-glandular densities) with the risk of interval cancer (IC) was investigated by reviewing a consecutive series of 346 cancers detected at screening (SDC) during 1996-1999 and of 90 ICs, reported as negative in the same period and diagnosed in the following 2 years, and comparing them to a random sample of 360 healthy controls. The probability of IC was significantly associated with breast density, whatever grouping (0/1-25/26-74/>74%; 0-25/26-60/61-74/>74%; 0-25/26-74/>74%) was considered (chi(2)=30.67-34.08, P<0.<0.01): 27.8% of all ICs were classified in the >74% density class, as compared to 7% of SDC and 5% of healthy controls. No significant association to IC was observed for Wolfe pattern (P2/Dy vs N1/P1: chi(2)=0.30, P=0.960), number of used mammographic views (single oblique vs oblique+craniocaudal: chi(2)=0.02, P=0.90) or screening round (first vs repeat: chi(2)=1.41, P=0.23). Multivariate analysis confirmed the independent association of breast density to IC, the highest risk being observed for >74% density class (OR vs 0% class=13.4, 95% CI 2.7-65.6, OR vs all other density classes=5.1, 95% CI 2.6-10.0). Age showed an independent association too, older women having a lower risk of IC (OR=0.52 95% CI 0.3-09). Breast density (>74%) resulted as being a major determinant of IC. Special screening protocols (shorter rescreening interval, routine use of ultrasonography) might be suggested for these subjects in order to improve screening sensitivity and efficacy.

Aged↗

Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review.

The study evaluates the role of computer-aided detection (CAD) in improving the detection of interval cancers as compared to conventional single (CONV) or double reading (DOUBLE). With this purpose, a set of 89 negative cases was seeded with 31 mammograms reported as negative and developing interval cancer in the following 2-year interval (false negative (FN)=11, minimal signs (MS)=20). A total of radiologists read the set with CONV and then with CAD. Overall, there were 589 cancer and 1691 noncancer readings with both CONV and CAD. Double reading was simulated by combining conventional readings in all 171 possible combinations of 19 radiologists, resulting in a total of 5301 cancer and 15 219 noncancer readings. Conventional single, DOUBLE and CAD readings were compared in terms of sensitivity and recall rate. Considering all 19 readings, cancer was identified in 190 or 248 of 589 readings (32.2 vs 42.1%, chi(2)=11.80, df=1, P<0.01) and recalls were 287 or 405 of 1691 readings (16.9 vs 23.9%, chi(2)=24.87, df=1, P<0.01) at CONV or CAD, respectively. When considering FN and MS cases separately, sensitivity at CONV or CAD was 50.2 or 62.6% (chi(2)=6.98, df=1, P=0.01) for FN and 22.3 or 30.7% (chi(2)=6.47, df=1, P=0.01) for MS cases, respectively. Computer-aided detection (average of 19 readings) was slightly and not significantly less sensitive (sensitivity: 42.1 vs 46.1%, chi(2)=3.24, df=1, P=0.07) but more specific (recall rate 23.9 vs 26.1%, chi(2)=3.8, df=1, P=0.04) as compared to DOUBLE (average of 171 readings). Average sensitivity for FN cases only was 62.6% for CAD and 64.8% for DOUBLE (chi(2)=0.32, df=1, P=0.58). Corresponding values for MS cases were 30.7% for CAD and 35.7% for DOUBLE (chi(2)=3.53, df=1, P=0.06). Compared to CONV, CAD allowed for improved sensitivity, though with reduced specificity, both effects being statistically significant. Computer-aided detection was almost as sensitive as DOUBLE but significantly more specific. Computer-aided detection might be used in the current practice to improve sensitivity of conventional single reading. Based on estimates of screening sensitivity and FN/MS interval cancer expected frequency, the absolute increase of screening sensitivity expected by introducing CAD-assisted reading may be estimated around 0.9%. The use of CAD as a possible surrogate to conventional DOUBLE needs to be confirmed by further studies, which should include a cost-effective analysis.

Breast Neoplasms↗

Surveillance for endometrial cancer with transvaginal ultrasonography of breast cancer patients under tamoxifen treatment.

The association of endometrial thickness with the risk of developing endometrial cancer (EC) within 2 years was investigated in a consecutive cohort of 1205 breast cancer patients under tamoxifen treatment, undergoing transvaginal ultrasonography (TVUS) for follow-up purpose (asymptomatic, 1068) or for abnormal uterine bleeding (AUB, 137). Linkage with tumour registry allowed for the follow-up of 3184.3 person-years. According to underlying incidence, 1.85 EC cases were expected in the study cohort while 12 were observed (observed/expected ratio=6.49, 95% CI 3.35-11.33; asymptomatic=4.09, 95% CI 1.65-8.43, symptomatic=35.71, 95% CI 11.59-83.34). No EC was observed with thickness (half layer) <3 mm. Raising this threshold increased specificity with a substantial loss of sensitivity (>or=3, >or=4, >or=6, >or=9 mm; spec.=25.8, 44.5, 76.1, 91.5%, sens.=100, 91.6, 75.0, 66.6%). The presence of AUB was rather specific (88.94%) but poorly sensitive (41.67%). A combination of AUB presence/absence and thickness allowed the best accuracy (AUB + thickness >or=3, >or=4 or >or=5; sens.=100, 81.6 or 91.6%; spec.=22.8, 40.4, or 56.7%). Breast cancer patients under tamoxifen might be selected for further invasive assessment on the basis of AUB and endometrial thickness assessed at TVUS.

Aged↗