PubMed Health⌕ Search

Biomedical subjects

S Coffin

Publications and source records attributed to S Coffin.

6 recordsLinked to original sources

Performance of anesthesia machines' devices that are not part of the Food and Drug Administration's daily checkout.

OBJECTIVE: The Food and Drug Administration's (FDA) checkout recommendations are to be applied, at least daily, on anesthesia machines. Devices included in the checkout are crucial to the safe operation of the machine. Remaining devices do not need to be checked as often. However, they should be checked at some appropriate interval. We calculated the reliability of the non-FDA checkout devices, to predict failure rates of these devices. METHODS: The study included 36 North American Drager Narkomed anesthesia machines that were in service a total of 109,410 days at a university hospital. Reliability (i.e., statistical) analyses were done using in-house data recorded by biomedical technicians during 3359 monthly machine inspections. If any one device was operating outside of the limits of the manufacturer's specifications, the machine was labeled as having failed its inspection. RESULTS: Assumptions of the failure analysis were satisfied. The mean time between failures equaled 1351 days or 3.7 years (lower 95% confidence bound 1123 days or 3.1 years). The mean daily probability of one or more devices failing to perform within the manufacturer's specification between inspections equaled 1.1, 2.2%, and 4.4% for inspections every 1, 2, or 4 months, respectively. Probabilities that a machine would fail on demand between inspections were approximately equal to the mean daily probabilities of machine failure. The mean number of days per year that a machine would be operating with a device that is outside of the limits of its specifications equaled 4, 8, and 12, days, respectively. The mean daily probabilities of failure and the probabilities of failure on demand were both directly proportional to the inspection interval. CONCLUSIONS: Our failure analysis provides a rational basis for choosing an appropriate inspection interval for anesthesia machines' devices that are not included in the FDA's checkout recommendations.

Anesthesiology↗

Decreases in anesthesia-controlled time cannot permit one additional surgical operation to be reliably scheduled during the workday.

We tested whether anesthesiologists can decrease operating room (OR) costs by working more quickly. Anesthesia-controlled time (ACT) was defined as the sum of 1) the time starting when the patient enters an OR until preparation or surgical positioning can begin plus 2) the time starting when the dressing is finished and ending when the patient leaves the OR. Case time was defined as the time starting when one patient undergoing an operation leaves an OR and ending when the next patient undergoing the same operation leaves the OR. An actual case series was constructed of 709 consecutive patients who underwent one of 11 elective operations at a tertiary care center. Statistical analysis of measured OR times showed that ACt would have to be decreased by more than 100% to permit one additional scheduled, short (30-min) operation to be performed in an OR during an 8-h workday after a prior series of cases, each lasting more than 45 min. Anesthesiologists alone cannot reasonably decrease case times sufficiently to permit one extra case to be reliably scheduled during a workday. Methods to decrease ACT (e.g., using preoperative intravenous catheter teams, procedure rooms, and/or shorter acting drugs) may simply increase costs.

Ambulatory Surgical Procedures↗

Prevalence of feline leukemia virus infection among adult cats at an animal control center: association of viremia with phenotype and season.

The overall frequency of feline leukemia virus infection among 555 cats tested from the Hillsborough County Florida Animal Control facility, using a commercial enzyme-linked immunosorbent assay, was 9.4%. Among male cats, the frequency was 13.8%, which was statistically higher (P = 0.003) than that for females (5.9%). There was no statistical evidence to associate frequency of viral infection with hair length or coloration. There was an association with color distribution. The frequency of viral infection in cats with a solid color in their coat, excluding tabby, calico, and tortoise, was higher (12.2%) than the frequency in the remainder of the cats (5.5%; P = 0.011). Finally, there was a difference in frequency related to season. For the 10 months of the study, cats collected in the 5 cooler months (January, February, March, April, and October) had a frequency of 14.6%; cats obtained in the 5 warmer months (May, June, July, August, and September) had a frequency of 7.2% (P = 0.038).

Animals↗