A neural approach to extract foreground from human movement images.

In recent years many approaches to foreground extraction from images related to human movement have been presented. The foreground extraction represents a pre-processing procedure to be implemented in a system for capturing human movement in order to facilitate the tracking of anatomical landmarks on human bodies. In this work, an approach based on an unsupervised neural network has been studied: a Kohonen map has been designed to recognize and separate structures characterizing foreground and background. The proposed technique is fully automatic and its performance has been compared with those of two further approaches based on differences between foreground and background images. In order to quantify the segmentation quality, an already validated, objective, and automatic criterion has been used. The obtained results are adequate with the final aim of the application and show the feasibility of the proposed approach.

Algorithms↗

The sensitivity of posturographic parameters to acquisition settings.

The objective of this study was to evaluate the sensitivity of posturographic parameters (PP) to changes in acquisition settings. A group of eight young adults underwent a set of typical orthostatic posture trials, and selected PP were then calculated from a set of centre of pressure (CoP) displacement time series obtained by applying different cut-off frequencies to the same set of raw data. Four PP out of 11 showed significant changes with respect to cut-off frequency. Statistical mechanics parameters exhibited smaller sensitivity than summary measures. On the basis of the results obtained, a proposal for a standard cut-off frequency and a sampling rate value is embodied in the paper together with some suggestions on measurement settings, with a view to standardized use of instrumentation for quantitative analysis in orthostatic posturography.

Acceleration↗

Hemodynamics as a possible internal mechanical disturbance to balance.

The postural control system is assessed by observing body sway while the subject involved aims at maintaining a specified up-right posture. Internal masses generate internal reaction forces that constitute an internal mechanical stimulus that may contribute to cause segmental displacements, i.e. body sway. Thus, gaining knowledge about the amplitude and direction of these reaction forces would contribute to gain insights into the mechanisms that influence the maintenance of balance and into its control. The 3-D force vector that acts on the body centre of mass (COM) and is associated with the transient blood movement at each cardiac cycle was assessed in a population sample of 20 young adults during the maintenance of a quiet up-right posture. Typical patterns of the three components of this force vector were identified. Relevant parameters were selected and submitted to sample statistics. For a number of them, linear correlation with subject-specific parameters was found. The antero-posterior force component was characterised by a triphasic major wave, the peaks of which had values up to 0.40 N. The vertical component showed a repeatable triphasic wave with peak-to-peak values in the range 1.3-3.0 N. The medio-lateral component showed relatively low peak-to-peak values (in the range 0.05-0.10 N). The resultant vector had an amplitude that underwent several oscillations during the cardiac cycle and reached its maximal value in the range 0.6-1.7 N.

Adaptation, Physiological↗

Synchronized approximately 15.0-35.0 Hz oscillatory response to spatially modulated visual patterns in man.

When suitably stimulated, neurons in the striate visual cortex of cats fire in bursts at 20-60 Hz and the membrane potential oscillates rhythmically in the same frequency range and in phase. These oscillations reflect intrinsic properties of mammalian neurons, occur in coherent spatial patterns that depend on the segregation and stimulus selectivity of stimulated cells, and mediate in long-range synchronization across columns and over large cortical areas of cells responding to the same stimulus property/properties. The pool of activated neurons may be adequate in size to drive cellular oscillations into local fields and mass responses. Accordingly, stimulus-dependent oscillatory activity in the same frequency range was described in man after contrast stimulation. Our results describe oscillatory potentials at approximately 15.0-35.0 Hz that in man are (partly) independent from, and anticipate the occurrence of, the conventional low-frequency visual response evoked by transient, foveal stimulation with spatially-modulated patterns.

Adult↗

Optimal rejection of movement artefacts from myoelectric signals by means of a wavelet filtering procedure.

In this work the problem of rejection of motion artefacts from surface myoelectric signals, recorded during dynamic contractions, is studied. In fact, the extraction of frequency parameters and the detection of muscular activation patterns can be detrimentally affected by artefacts due to the movement of the surface electrodes, particularly stressed by the dynamic conditions of the exercise performed during measurement. In order to overcome this difficulty, four different filtering procedures have been tested and compared: a high-pass filtering procedure, a moving average procedure, a moving median procedure and a new adaptive wavelet based procedure, expressly designed for this work. Orthogonal Meyer wavelets are used with the aim of obtaining both a good reconstruction and a decomposition of the signal into non-overlapping bands. The four procedures have been tested with a set of different proofs utilising both synthetic and experimentally recorded myoelectric signals. The results show that the wavelet procedure performs better than the other methods both in information preservation and in time-detection. Moreover, the features of user-independence and adaptivity to the noise level suggest a wider range of applications of the proposed algorithm.

Adult↗

Real time monitoring of muscular fatigue from dynamic surface myoelectric signals using a complex covariance approach.

A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computation of the complex covariance and then of the mean frequency. The results show good performance on both synthetic and experimental non-stationary myoelectric signals recorded during fatiguing dynamic protocols. Performance in the presence of noise is highly satisfactory on both deterministic signals and stochastic processes, even when there are strong non-stationarities. Moreover, the computational complexity is highly reduced with respect to that offered by traditional methods based on short time Fourier transform.

Adult↗

High-quality compression of echographic images by neural networks and vector quantisation.

A compression method is presented for medical images based on neural networks and vector quantisation (VQ). The neural net is a perceptron and it is followed by some expressly designed VQ algorithms. The method devotes special attention to the quality of the reconstructed images and to the reduction of artefacts. The compression ratio obtained in the long run with echographic images is greater than 50:1 with good quality.

Algorithms↗