Four-year follow-up results of lumbar spine arthrodesis using the Bagby and Kuslich lumbar fusion cage.

STUDY DESIGN: This was a prospective multicenter clinical trial of a lumbar interbody fusion cage with a minimum of 4 years' follow-up. OBJECTIVES: To determine whether the early positive clinical results in fusions with lumbar cages, such as the Bagby and Kuslich (BAK) cage, are maintained beyond 2 years. SUMMARY OF BACKGROUND DATA: Threaded cages have been used increasingly for the treatment of symptomatic degenerative intervertebral disc disease. Concerns about the long-term clinical outcomes of this procedure have been posed, particularly regarding bony fusion viability, revision rates, potential adjacent level disease, and late complications. METHODS: The study cohort was a 196-patient subset from a prospective investigational device exemption. In addition to early postoperative examinations, these patients were examined biannually with a minimum of 4 years' follow-up. Patient outcome was assessed by a 6-point scale that evaluated pain relief, and functional improvement was determined by changes in activities of daily living. Fusion rates and return to work were determined. Complications and secondary operations were reported and categorized as non-device related or device related. RESULTS: The patient cohort with 4-year follow-up represented 25.6% of the original study population eligible at that time. Overall, the largest percentage of pain relief and functional improvements occurred by 3 months, and these improvements were maintained at each follow-up. Overall fusion rate was 91.7% and 95. 1% at 2 and 4 years, respectively. In this cohort, 39.5% of patients were working or were able to work within 3 months of surgery. After 4 years, 62.7% of patients were gainfully employed or able to work. The late-occurring complication rate in this cohort was 13.8% (27/196). Complications necessitating a second operation occurred in 8.7% (17/196), whereas reoperations that were deemed device related were performed in 3.1% (6/196). CONCLUSIONS: This study indicates that the early positive benefits of interbody fusion cage procedures are maintained through 4 years with acceptably low morbidity.

Cohort Studies↗

The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow-up results of a United States prospective, multicenter trial.

STUDY DESIGN: A prospective, multicenter trial of the Bagby and Kuslich method of lumbar interbody stabilization for chronic discogenic low back pain, with follow-up evaluation at 3 months, 6 months, and yearly thereafter, with independent radiographic analysis. OBJECTIVES: To report the history of development, the surgical techniques, and results of the Bagby and Kuslich method when used to manage discogenic pain of the lumbar spine in humans. SUMMARY OF BACKGROUND DATA: Disabling chronic low back pain frequently is resistant to conservative management. The "Bagby Basket" effectively has fused the equine and baboon spine. The results of biomechanical and animal studies performed over the last 20 years have suggested that a similar but improved design--the Bagby and Kuslich device--would be useful in stabilizing the human spine. METHODS: From 1992 to 1995, 947 patients with chronic discogenic low back pain were treated by Bagby and Kuslich interbody fusion in a strict, multicenter, prospective clinical trial by using either the open anterior or open posterior approach. The study involved 42 surgeons at 19 medical centers. The authors of the current report analyzed the fusion rates, pain relief, functional status, and complications occurring in patients who underwent long-term follow-up observation. RESULTS: The Bagby and Kuslich method is safe and effective when compared with methods described in previous reports of posterior and anterior lumbar interbody arthrodesis performed by using bone graft alone. Fusion occurred in 91% of patients at 24 months after surgery, and pain was eliminated or reduced in 84%. Function was improved in 91%. There were no device-related deaths, cases of major paralyses, device failures, or deep infections. CONCLUSIONS: Carefully selected middle-aged patients with chronic low back pain secondary to degenerative disc disease can be treated effectively and safely by skilled surgeons using the Bagby and Kuslich device for one- and two-level interbody fusion.

Adult↗

The tissue origin of low back pain and sciatica: a report of pain response to tissue stimulation during operations on the lumbar spine using local anesthesia.

In an effort to define the origin of low back pain and sciatica, 193 patients were carefully studied using progressive local anesthesia. These patients had surgery for herniated discs, spinal stenoses, or both. Various tissues were stimulated during the performance of these lumbar spinal operations. This article discusses our observations and the results of that study.

Anesthesia, Local↗

Air embolism in spinal surgery.

We present two cases of fatal venous air embolism that occurred in previously healthy adolescents during posterior spine fusion and instrumentation for scoliosis. Previously recorded cases in the literature have been rare and only briefly discussed. Air embolism has been a complication noted in the anesthesia and neurosurgical literature, occurring primarily in total hip patients and those patients undergoing neurosurgical procedures in a sitting position. An examination of the pathophysiology of air embolism in posterior spinal procedures would indicate the use of properly placed central lines and end-expiratory CO2 monitoring as the primary modes of detection and treatment considering the potentially fatal risk factors for spinal patients.

Adolescent↗

The human element in the design of computer-assisted orthopedic inpatient medical record systems.

It is possible to vastly improve the quality of the "final product" of medical record processing by use of word and data base processing systems without traditional programming and expensive mainframe computers. Human engineering features need to be addressed first, since these form the basis of the system for obtaining quality data. Successful operations of the system is dependent upon a close working relationship between the staff of the medical record department and the medical staff.

Forms and Records Control↗

Office automation for the orthopedic surgeon.

What are the essential elements of office automation that can be directly applied to the practice of orthopedics? New technology, when implemented into a planned, logical system, can increase practice efficiency and productivity.

Ambulatory Care Information Systems↗