Mediastinal abscess successfully treated by percutaneous drainage using a unified CT and fluoroscopy system.

We report two patients with mediastinal abscess developing after surgery for oesophageal cancer who were treated by percutaneous drainage using a unified CT and angiography system, which allows both CT and fluoroscopy to be conducted with the patient on the same bed. Fine needle puncture is performed under CT guidance and this needle is used as a tandem for insertion of the drainage needle under fluoroscopic guidance, making safe puncture possible whilst confirming the position of the needle tip. Moreover, contrast medium can be injected from the drainage tube, allowing the extent of the abscess cavity to be determined by fluoroscopy and CT, thereby making accurate drainage possible.

Abscess↗

Severe obstruction of the superior vena cava caused by tumor invasion. Recanalization using a PTFE-covered Z stent.

Bare stents are commonly used for the treatment of malignant vena cava stenoses. However, the therapeutic effect of treatment using bare stents for cases with intraluminal tumor invasion is not satisfactory. We report a case with severe obstruction of the superior vena cava caused by tumor invasion of mediastinal lymph node metastases from colon cancer, which was successfully treated by the recanalization of superior vena cava using a polytetrafluoroethylene-covered Z stent. The covered stent could not be fully expanded at first, and re-obstruction developed at the stented site due to thrombus formation soon after stenting. So, the additional balloon dilatation made the stent expend fully on another day of stenting. After the balloon dilatation blood flow improved immediately and the clinical symptoms associated with the superior vena cava obstruction resolved. Thereafter no symptomatic recurrence has been observed in 12 months of follow-up period.

Angioplasty, Balloon↗

Altered hepatic hemodynamics caused by temporary occlusion of the right hepatic vein: evaluation with Doppler US in 14 patients.

PURPOSE: To evaluate with Doppler ultrasonography (US) the altered hepatic hemodynamics caused by temporary occlusion of the right hepatic vein. MATERIALS AND METHODS: The study group consisted of 14 patients being considered for hepatic arterial infusion or transarterial embolization. In all patients, maximum peak velocity of the blood flow in the right portal vein was measured with Doppler US before and during the occlusion of the right hepatic vein. In 13 patients, color Doppler US was performed to evaluate Doppler signal in the portal venous branch in the occluded area before and during occlusion. Average peak velocity in the right hepatic artery in eight patients was measured by using a transducer-tipped guide wire before and during occlusion. RESULTS: Maximum peak velocity of the right portal vein significantly decreased with occlusion (P <.01). Hepatic venous occlusion changed the Doppler signal in the portal venous branch in the occluded area from hepatopetal to no signal in 10 patients; to weakened hepatopetal in two; and to hepatofugal in one. Average peak velocity of the right hepatic artery showed a decrease or plateau for 15-30 seconds after the start of occlusion and then a rapid increase to reach a plateau at around 75-90 seconds, with 1.5-2 times as much velocity as that before occlusion. CONCLUSION: Increase in hepatic arterial velocity is accompanied by a decrease in the portal velocity with temporary occlusion of the right hepatic vein; the expected increased drainage through the portal vein was almost undetectable.

Aged↗

Case report: Hepatic arterial occlusion following infusion catheter placement: recanalization using the Palmaz stent.

We report two cases in which hepatic arterial occlusion developed soon after percutaneous catheter placement for hepatic arterial infusion chemotherapy in malignant hepatic neoplasms. A replaced hepatic artery and a proper hepatic artery, respectively, became occluded in these cases. In both, because the tip of a side-holed catheter for arterial infusion was fixed in place, we performed recanalization without removing the indwelling catheter. Despite the presence of the catheter, a stent could be inserted into the occluded portion of the hepatic artery. Recanalization of the hepatic artery was achieved with stent placement, and continuation of hepatic arterial infusion became possible.

Arterial Occlusive Diseases↗

Recanalization 24 months after endovascular repair of a large internal iliac artery aneurysm with use of stent-graft.

An 83-year-old man with a large internal iliac artery aneurysm (IIAA) was treated with the use of stent-graft, suggesting successful results at 3, 6, and 12 months after treatment. However, 24-month follow-up computed tomography showed minor peripheral opacification of the IIAA. The patient underwent surgical endoaneurysmorrhaphy. No previous report of long-term recanalization of a satisfactorily thrombosed iliac artery aneurysm at 2 years or more after stent-grafting has been previously reported. Further follow-up studies need to be performed on the present procedure before anyone can confidently recommend it in regard to its long-term safety.

Aged↗

[Biopsy].

We reviewed the current devices, techniques, guiding images, indications and complications of needle biopsy with CT guidance. The development of new devices such as automated cutting needle has enabled radiologists to obtain tissue specimens of good quality at biopsy. Techniques such as the tandem or coaxial method ensure more a more accurate biopsy route. And helical CT and CT fluoroscopy have markedly shortened the time required for needle biopsy. However, we sometimes encounter minor complications, and rarely major ones, during and after needle biopsy. Some of these complications may be caused by malpractice. Therefore it is important always to pay attention to the possibility of complications of needle biopsy and to minimize radiation exposures from CT fluoroscopy.

Biopsy, Needle↗