PubMed Health⌕ Search

Biomedical subjects

S E North

Publications and source records attributed to S E North.

6 recordsLinked to original sources

An exploration of the structure-activity relationships of 4-aminoquinolines: novel antimalarials with activity in-vivo.

The structure-activity relationships of bisquinolines, a potentially important group of novel antimalarial drugs, were studied. The high-temperature (180-250 degrees C) synthesis of 4-aminoquinolines, including bisquinolines, by nucleophilic displacement was both fast and efficient Several bisquinolines including (+/-)-trans-N1,N2-bis(7-trifluoroquinolin-4-yl)cyclohexane-1, 2-diamine and 1R,2R-(-)-, 1S,2S-(+)-, (+/-)-trans- and cis-N1, N2-bis(7-chloroquinolin-4-yl)cyclohexane-1,2-diamine exhibited potent activity against Plasmodium berghei in mice; (+/-)-trans-N1,N2-bis(7-chloroquinolin-4-yl)cyclohexane-1, 2-diamine was orally active. Our results indicate that these compounds conform to a putative receptor for quinoline antimalarials. In addition, a 7-haloquinoline linked by a heterocyclic bridge, at the 4-position, to another heterocycle (such as an acridine at the 9-position) maximally occupies the active site of our postulated target.

Aminoquinolines↗

Evaluation of home glucose measuring devices.

A large number of glucose-monitoring systems suitable for home use are now available. The Glucochek, an early model (Mk I) and a later (Mk II), the Stan Clark RAHC, the Glucometer, and 20-800 BM glycemie strips were evaluated with regard to accuracy, precision, model variability and operator variability before a particular system was recommended for patient use. Whole blood glucose, on samples samples taken in the Diabetic Clinic of The Royal Melbourne Hospital, Melbourne, was measured with the system under test and in the Biochemistry Department. Accuracy was indicated by the mean of the differences between the two results, and precision by the standard deviation of these differences-the closer these results to zero, the better the system. The 20-800 BM Glycemia strips gave the best results in the hands of an experienced operator, but showed the greatest interoperator differences. These differences decreased when a machine-based system was employed. The Glucochek Mk I did not perform satisfactorily. All the systems tested showed a marked decrease in accuracy and precision when blood glucose levels were greater than 15.0 mmol/L. These results show that a machine is not a necessary part of a home glucose-monitoring system; that patients on home glucose-monitoring must be trained and their results checked against a reference method initially and, ideally, at regular intervals; that home glucose-monitoring in patients with marked hyperglycaemia unreliable.

Blood Glucose↗