A high-intensity, goggle-mounted flash stimulator for short-latency visual evoked potentials.

The few studies that have been done on short-latency, subcortical visual evoked potentials (SVEPs) have all used stroboscopic flashes as the evoking stimulus. The dimensions of the stimulator, the acoustical artifacts and the photic spread to the examination room limited the use of SVEPs to research laboratories. With the advent of high-efficiency light-emitting diodes (LEDs), high-intensity flashes can now be generated from goggle-mounted LEDs. In this study, a goggle-mounted high-intensity stimulator was constructed and its flashes used to evoke SVEPs. The reproducibility of SVEPs across subjects and the ease of using the high-intensity LED flash stimulator make them a promising candidate for testing subcortical visual pathway function in the operating room.

Cerebral Cortex↗

Real-time monitoring of visual evoked potentials.

Steady-state visual evoked potentials (SSVEP) were recorded in response to flashes from eyepatch-mounted light-emitting diodes during neurological surgery and in the intensive care unit. SSVEP were detected and measured with a microprocessor-based waveform correlator. The system enabled a continuous display, in real time, of SSVEP amplitude and latency. SSVEP amplitude and latency changes were monitored throughout a variety of surgical procedures. Some of these procedures directly affect the central visual pathway, some affect the central nervous system as a whole, while others do not affect central nervous system function. In addition, intensive care unit patients with a variety of intracranial pressures were monitored. The results of this study indicate that SSVEP recorded with this method showed changes in SSVEP within seconds of surgical and/or medical decompression of intracranial pressure and were sensitive to specific changes in the visual pathway. Surgical procedures that directly affected the visual system, or elevation of intracranial pressure, resulted in changes in SSVEP. In contrast, procedures that did not affect the functional integrity of the visual system did not affect the recordings.

Adenoma↗

Miniature fiber-optic pattern-reversal stimulator for determination of the visual evoked potential threshold; comparison with Snellen acuity.

In this report we recommend the estimation of visual acuity by detection of the visual evoked potential (VEP) threshold, defined by the smallest visual angle of a constant check size that evokes potentials. This approach was implemented using a fiber-optic pattern-reversal stimulator placed at measured, increasing distances from the examined eye. Snellen visual acuity as determined in 113 subjects was correlated with the VEP detection threshold. A highly significant correlation was found between visual acuity and the threshold visual angle of check size in subjects whose vision was impaired due to opacity in ocular media. For any given visual acuity a somewhat wide range of threshold check sizes, typically 5-10 min of arc was observed. Technical difficulties that need to be overcome to improve these results are discussed.

Adult↗

Comparison of fiber optical and video monitor stimulators in normals and multiple sclerosis patients.

A comparison of VEP findings using a fiber optical stimulator with three color combinations (black/red, black/green and red/green) and a conventional video monitor stimulator in black/white was performed in 3 groups of subjects: a group with definite lesions in the visual pathway, a group with suspected lesions and a control group. No significant correlations of P100 latency were found in the normative group, probably because of the small range of their values. All correlations were significant in the two patient groups, except for the red/green stimuli in the definite group. In general, the red/green combination was inferior to other color combinations in eliciting VEPs. The patient groups with definite, as well as suspected, lesions indicated no benefit from the color stimuli, as compared with black/white. The major advantage of the fiber optical stimulator is its simplicity, the lack of stimulus artifacts and the accessibility to the patient's bed side, thanks to its small size. Stimulators with higher illuminance and improved pattern element shape should narrow the still unacceptable normative variability of the wave forms recorded.

Adolescent↗

Detection and measurement of steady-state evoked potentials in real-time using a lock-in amplifier. Technical note.

A system for recording evoked potentials, in which a lock-in amplifier replaces the averaging computer, is described. With this system, the set-up is much the same as in the conventional apparatus, with the following exceptions: 1) the amplifier gain is set at only a few thousands; 2) analogue-to-digital conversion and computer averaging is replaced by a lock-in amplifier; and 3) the output of the system is an analogue signal representing the amplitude of the recorded steady-state evoked potentials and the phase of baseline crossings. This set-up is much less costly than the conventional apparatus, much easier to operate, and, with its real-time output, may provide an ideal technique for screening and monitoring purposes.