PubMed Health⌕ Search

Biomedical subjects

S Eskin

Publications and source records attributed to S Eskin.

2 recordsLinked to original sources

Effect of seeding density and time in culture on vascular smooth muscle cell proteins.

The purpose of this work was to determine the effect of seeding density and time in culture on quantitative and qualitative characteristics of myosin in primary cultures of vascular smooth muscle cells (VSMCs). Enzymatically dispersed VSMCs from femoral arteries and saphenous veins of adult dogs were seeded at a density of 10(3)-10(5) cells/cm2 and assayed after 7 days or at 10(5) cells/cm2 and assayed between 1 and 10 days. Myosin, actin, and total protein contents as well as electrophoretic and immunoreactive characteristics of myosin heavy chains (MHCs) were determined. Total and contractile protein contents were independent of seeding density and increased with time in culture. Freshly dispersed cells exhibited two MHCs (MHC-1 and MHC-2) but, within 24 h after culturing, only cells attached to the dish expressed a third protein band (MHC-3), which had electrophoretic mobility and immunoreactivity similar to purified platelet MHC. MHC-3 appeared before onset of cell division and, by 4 days in culture when cells were proliferating, became the dominant MHC form. Loss of MHC-1 and MHC-2 could be prevented by growing cells in a serum-free, defined media that prevented proliferation. These data indicate that seeding density does not affect myosin content, but that with time in culture expression of a MHC with characteristics similar to nonmuscle myosin occurs. Expression of MHC-3 is associated with cell attachment, whereas loss of MHC-1 and MHC-2 requires proliferation.

Actins↗

Oxidized orlon as a blood interface.

Polyacrylonitrile fabric (Orlon) may by oxidized by heating in air, when it becomes black and carbonized. During the heat treatment, the fibers shrink; this shrinkage allows components such as diaphrams to be shaped around molds. Oxidation reduces the tensile strength by about 25% and also reduces the stiffness of the material. The oxidized Orlons was screened in tissue culture for possible cytotoxic effects. Finding none, patches of the material were sutured into the right atrium of dogs and examined after 48 hr. Because of encouraging results, 10 atrial patches, consisting of Dacron velour and oxidized Orlon side-by-side, were implanted into the right atrium of dogs. Five patches were backed with Silastic to render them impervious, and five with segmented polyurethane. The atrial patches were examined after 48 hr, and in all instances the oxidized Orlon part of the patch was coated with a thinner and smoother fibrin layer than was the Dacron velour half. a left ventricular bypass pump was fabricated from oxidized Orlon and spray-coated on the nonblood surface with segmented polyurethane. After 48 hr implantation in the chest cavity of a calf, pumping without systemic anticoagulation, the pump was found covered by a thin, smooth, firmly attached layer of fibrin.

Acrylic Resins↗