Effect of 24-hour blood pressure and heart rate variations on left ventricular hypertrophy and dilatation in essential hypertension.

This study correlates variables derived from blood pressure (BP) and heart rate (HR) monitoring with the degree of left ventricular structural changes in essential hypertension. Forty patients with mild-to-moderate hypertension according to World Health Organization criteria underwent 24-hour ambulatory monitoring. Echocardiographic (posterior wall and interventricular septum thickness, left ventricular mass) or ECG (SV1 + RV5) indices of hypertrophy were significantly (p less than 0.01) correlated (positive correlations) with derivatives of BP monitoring (mean systolic and diastolic BP values) but not with HR derivatives. Echocardiographic indices of dilatation (left ventricular end-diastolic volume and diameter) were significantly (p less than 0.01 to less than 0.001) correlated (negative correlations) with derivatives of HR monitoring (mean HR values, mainly during the night) but not with BP derivatives. It is concluded that in essential hypertension, left ventricular hypertrophy depends on mean 24-hour systolic and diastolic BP values, whereas left ventricular dilatation appears to be more prominent in patients with bradycardia mainly during the night.

Adult

Intraventricular plus intra-aortic balloon pumping during intractable cardiac arrest.

A method is presented for maintaining aortic flow by mechanical means during intractable cardiac arrest. A spherical balloon was inserted into the left ventricle while the usual intra-aortic balloon was introduced into the thoracic aorta. Ventricular fibrillation was induced by direct current. The pumps operating the two balloons were adjusted to inflate the intraventricular balloon during one third of the pumping cycle and the intra-aortic balloon during the next two thirds of the same cycle. The intraventricular balloon capacity varied from 40 to 110 ml (six dogs weighing 16-24 kg) while the intra-aortic balloon capacity was 20 ml. An optimal pumping rate of 75 beats/min maintained an aortic flow of 0.9-1.5 ml/beat/kg and a mean pressure into the brachiocephalic trunk of 110 +/- 12.5 mm Hg (mean +/- SD). These experimental data indicate that an easily applied mechanical device system (needing no extracorporeal circulation) may be used to bridge the time between intractable cardiac arrest and implantation of an artificial heart or transplantation.

Animals