PubMed Health⌕ Search

Biomedical subjects

S Fantini

Publications and source records attributed to S Fantini.

15 recordsLinked to original sources

Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument.

The frequency-domain multiple-distance (FDMD) method is capable of measuring the absolute absorption and reduced scattering coefficients of optically turbid media. Absolute measurement of absorption at two near-infrared (NIR) wavelengths makes possible the quantitation of tissue haemoglobin concentration and tissue haemoglobin oxygen-saturation (StO2). However, errors are introduced by the uncertainties of background absorption and the dissimilarities between real tissues and the simplified mathematical model on which these measurements are based. An FDMD-based tissue instrument has been used for the monitoring of tissue haemoglobin concentration and oxygenation in the brain of newborn piglets during periods of hypoxia and hyperoxia. These tissue haemoglobin saturation values were compared with arterial saturation (SaO2) and venous saturation (SvO2) measured by blood gas analyses. A linear correlation was observed between StO2 and the average of SaO2 and SvO2. However, StO2 is not equal to any fixed weighted average of SaO2 and SvO2 unless we introduce an effective background tissue absorption. The magnitude of the background absorption was about 0.08 cm(-1) at 758 nm and 0.06 cm(-1) at 830 nm, and it was nearly consistent between piglets. The origin of this 'effective' background absorption may be real, an artefact caused by the application of a simplified model to a complex sample, or a combination of factors.

Animals↗

Blood flow and oxygen consumption with near-infrared spectroscopy and venous occlusion: spatial maps and the effect of time and pressure of inflation.

We have measured the local blood flow (BF) and oxygen consumption (OC) in the human calf muscle using near-infrared spectroscopy during venous occlusion. Venous occlusion was achieved by inflating a pneumatic cuff around the thigh of the subject. We have investigated the influence of the inflation time and cuff pressure on the recovered values of BF and OC. We have found that if the cuff pressure is increased from a threshold pressure (approximately 30 mm Hg) to a critical pressure (approximately 45 mm Hg) in less than about 6 s, one measures the same values of BF and OC independent of the total inflation time and final cuff pressure. We also report nine-pixel spatial maps of BF and OC to show that this technique can lead to spatially resolved measurements of blood flow and oxygen consumption in tissues.

Adult↗

Near-infrared study of fluctuations in cerebral hemodynamics during rest and motor stimulation: temporal analysis and spatial mapping.

We have noninvasively studied the motor cortex hemodynamics in human subjects under rest and motor stimulation conditions using a multichannel near-infrared tissue spectrometer. Our instrument measures optical maps of the cerebral cortex at two wavelengths (758 and 830 nm), with an acquisition time of 160 ms per map. We obtained optical maps of oxy- and deoxy-hemoglobin concentration changes in terms of amplitudes of folding average, power spectrum and coherence at the stimulation repetition frequency, and the phase synchronization index. Under periodic motor stimulation conditions, we observed coherence and frequency or phase synchronization of the local hemodynamic changes with stimulation. Our main findings are the following: (1) The amplitude of the hemodynamic response to the motor stimulation is comparable to the amplitude of the fluctuations at rest. (2) The spatial patterns of the oxy- and deoxy-hemoglobin responses to the stimulation are different. (3) The hemodynamic response to stimulation shows a spatial localization and a level of phase synchronization with the motor stimulation that depends on the stimulation period.

Adult↗

Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy.

We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 microM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intensity (dc slope method). The analysis of the cerebral optical signals associated with the arterial pulse and with respiration demonstrates that motion artefacts can significantly affect the intensity recorded from a single optode pair. Motion artefacts can be strongly reduced by combining data from multiple optodes to provide relative readings in the dc slope method. We also report significant biphasic changes (initial decrease and successive increase) in the reduced scattering coefficient measured in the brain after the piglet had been sacrificed.

Animals↗

Real-time optical imaging of experimental brain ischemia and hemorrhage in neonatal piglets.

Our objective was to study the development of experimental brain ischemia and hemorrhage by real-time optical imaging. Optical imaging is based on the ability of near infrared light to non-invasively penetrate through the intact scalp and skull and measure brain concentrations of oxy- and deoxyhemoglobin, dominant brain absorbers. Optical imaging was performed in 7 anesthetized, instrumented, and ventilated newborn piglets subjected to the injection of 0.3 cc of saline followed by 2 cc of blood into the left frontal subcortical brain region via a needle inserted through the skull with stereotactic guidance. The image-acquisition rate of 5.26 images per sec allowed for real-time imaging. The detection threshold of the imager at the estimated depth of 1-1.5 cm was approximately 70 microL for saline and approximately 40 microL for blood. The imager readily detected five subcortical hematomas and two large bilateral subarachnoid hemorrhages. The imager detected a global decrease in brain absorption associated with the volume-injection-related increase in intracranial pressure in the surrounding ipsilateral and contralateral brain. Any decrease in brain absorption is an equivalent to brain ischemia. This study demonstrates the capability of optical imaging in detecting brain ischemia and hemorrhage in real-time with high temporal and spatial resolution.

Animals↗

Application of near-infrared tissue oxymetry to the diagnosis of peripheral vascular disease.

Near-infrared spectroscopy (NIRS) is a noninvasive technique to measure the tissue oxygenation in real time. This optical method has many advantages over the invasive analysis currently used for clinical tests. Among the possible applications of near-infrared oxymetry, we report three protocols (exercise, venous occlusion and tilting table) in conjunction with NIRS, and discuss their applicability in the diagnosis of peripheral vascular disease (PVD).

Humans↗

Measurements of scattering and absorption changes in muscle and brain.

Non-invasive techniques for the study of human brain function based on changes of the haemoglobin content or on changes of haemoglobin saturation have recently been proposed. Among the new methods, near-infrared transmission measurements may have significant advantages and complement well-established methods such as functional magnetic resonance imaging and positron emission tomography. Near-infrared measurements can be very fast, comparable in speed to electrophysiological measurements, bur are better localized. We will present the demonstration of measurements of millisecond signals due to brain activity in humans following stimulation of the visual cortex. However, major unresolved questions remain about the origin of the signals observed. Optical measurements on exposed cortex in animals show that both the absorption and the scattering coefficient are affected by neural activity. Model calculations show that the signals we detected may originate from rapid changes of the scattering coefficient in a region about 1 to 2 cm below the scalp. We discuss our measurement protocol, which is based on a frequency-domain instrument, and the algorithm to separate the absorption from the scattering contribution in the overall response. Our method produces excellent separation between scattering and absorption in relatively homogeneous masses such as large muscles. The extrapolation of our measurement protocol to a complex structure such as the human head is critically evaluated.

Animals↗

Frequency-domain techniques enhance optical mammography: initial clinical results.

We present a novel approach to optical mammography and initial clinical results. We have designed and developed a frequency-domain (110-MHz) optical scanner that performs a transillumination raster scan of the female breast in approximately 3 min. The probing light is a dual-wavelength (690 and 810 nm, 10-mW average power), 2-mm-diameter laser beam, and the detection optical fiber is 5 mm in diameter. The ac amplitude and phase data are processed with use of an algorithm that performs edge effect corrections, thereby enhancing image contrast. This contrast enhancement results in a greater tumor detectability compared with simple light intensity images. The optical mammograms are displayed on a computer screen in real time. We present x-ray and optical mammograms from two patients with breast tumors. Our initial clinical results show that the frequency-domain scanner, even at the present stage of development, has the potential to be a useful tool in mammography.

Algorithms↗

Vascular effects of occupational exposure to low-dose ionizing radiation.

Damage to the microcirculation caused by high-dose ionizing radiation is well known but data concerning low-dose exposure are scant and contrasting. We employed capillary microscopy to study dermal microcirculation damage resulting from occupational exposure to ionizing radiation doses lower than 5 rem/year (maximum permissible dose in Italy). We studied 145 physicians (60.7% radiologists, 33.8% orthopedic specialists, 5.5% cardiologists) occupationally exposed to ionizing radiation and a control group of 106 subjects in comparable but different occupations not exposed to ionizing radiation or to other skin hazards. All subjects were administered a clinical protocol and underwent capillary microscopy of the fingernail-fold. Capillary microscopy alterations were classified as absent, mild, moderate, marked and severe. Our data confirm that occupational exposure to low-dose ionizing radiation can lead to morphological and functional alterations of the dermal microcirculation, which can be identified early by capillary microscopy.

Adult↗

Frequency-domain optical mammography: edge effect corrections.

We have investigated the problem of edge effects in laser-beam transillumination scanning of the human breast. Edge effects arise from tissue thickness variability along the scanned area, and from lateral photon losses through the sides of the breast. Edge effects can be effectively corrected in frequency-domain measurements by employing a two-step procedure: (1) use of the phase information to calculate an effective tissue thickness for each pixel location; (2) application of the knowledge of tissue thickness to calculate an edge-corrected optical image from the ac signal image. The measurements were conducted with a light mammography apparatus (LIMA) designed for feasibility tests in the clinical environment. Operating in the frequency-domain (110 MHz), this instrument performs a transillumination optical scan at two wavelengths (685 and 825 nm). We applied the proposed two-step procedure to data from breast phantoms and from human breasts. The processed images provide higher contrast and detectability in optical mammography with respect to raw data breast images.

Biophysical Phenomena↗

Role of frequency domain optical spectroscopy in the detection of neonatal brain hemorrhage--a newborn piglet study.

OBJECTIVE: Inability of continuous wave (CW) optical spectroscopy to measure changes in scattering, and the use of an arbitrary rather than an actual baseline, makes the CW method highly susceptible to errors that can lead to a false-positive or false-negative diagnosis. Our objective was to assess whether, and to what extent, the use of quantitative frequency domain spectroscopy would improve our ability to detect and monitor the development of brain hemorrhage. METHODS: A dual-channel frequency-domain tissue spectrometer (Model 96208, ISS, Inc., Champaign, IL) was used to monitor the development of experimental subcortical and periventricular-intraventricular hemorrhage (IVH) in 10 newborn piglets (blood injection model). The multidistance approach was employed to calculate the absorption and reduced scattering coefficients and hemoglobin changes from the ac, dc, and phase values acquired at four different source-detector distances and at 752 nm and 830 nm. RESULTS: There were significant absorption and scattering changes in the subcortical hematoma (n = 5) and the IVH groups (n = 5). The smallest detectable amount of blood in the brain was 0.04 ml. Changes associated with subcortical hematoma were several times higher than those associated with IVH, and correlated better with the estimated cross-sectional area of the hematoma than with the volume of the injected blood. As opposed to IVH, there was a significant absorption difference between the injured (subcortical hematoma) and normal side of the brain, probably because in case of IVH a significant volume of the injected blood had accumulated/spread beyond the reach of the probe. CONCLUSION: Clearly, frequency-domain spectroscopy cannot increase our ability to quantify the volume (size) or the oxygenation of the injected blood, especially in the case of IVH. However, the ability to quantify the baseline tissue absorption and scattering would significantly improve diagnostic performance, and may allow for early identification and treatment of neonatal brain hemorrhage.

Animals↗

Hypertension and chronic exposure to noise.

The effects of noise on various cardiovascular parameters are conflicting and uncertain. In the current study, the authors studied 52 workers who were employed in a bedframe factory who were chronically exposed to noise and who had poor hearing. An additional group of 65 workers who had jobs in the light-metal sector and another group of 64 office workers served as two control groups; none of the controls were exposed to noise, and none had hearing defects. Blood pressure was measured for each person in the supine and standing positions, and an electrocardiogram was also performed. Sound-level measurements were taken in the workplaces. Mean systolic and diastolic blood pressures and diastolic blood pressure distributions were significantly higher in the noise-exposed group than in both control groups. Among the three groups, there were significantly different frequencies of hypertension, drops in blood pressure, and electrocardiogram anomalies. Within the group of bedframe workers, those exposed to a personal daily level of exposure (i.e., equivalent continuous noise level for exposure to noise for each individual workers in an 8-hr shift) that exceeded 90 dBA had a higher mean diastolic blood pressure and a higher frequency of diastolic hypertension than workers exposed to a personal daily level of exposure of < 90 dBA. The findings suggested that (a) work performed by the bedframe group had some effects on the cardiovascular system, (b) noise is a cardiovascular risk factor, and (c) cardiovascular effects are relative to intensity and type of exposure. Vascular damage often accompanies auditory damage, but--depending on individual susceptibility--the cardiovascular system can respond in various ways.

Adult↗

[Chronic noise exposure and the cardiovascular system in aircraft pilots].

The aim of this study was to assess whether pilots are exposed to any risk of effects on the cardiovascular apparatus, whether chronic exposure to noise can be a risk factor for this occupation, the importance of intensity, length and type of exposure to noise, and if any relationship exists between audiometric deficits and cardiovascular effects. The study comprised 416 pilots subdivided into two groups according to the different levels of chronic exposure to noise, and a group of 150 control subjects not exposed to noise. The results showed: a) a higher prevalence of hypertension, nearly always diastolic, and of ECG abnormalities in the group of pilots of turboprop aircraft compared to jet plane pilots and to controls (p < 0.005 and p < 0.01 respectively); b) a higher prevalence of orthostatic hypotension in the two groups of pilots than in the controls (p < 0.05); c) a higher prevalence of hypertension with audiometric deficit compared to hypertension without audiometric deficit both in the more heavily and in the less heavily exposed to noise (p < 0.05), and a higher prevalence of hypertension with audiometric deficit in subjects exposed to higher levels of noise compared to hypertension with deficit but in subjects with lower levels of exposure (p < 0.05); d) a higher prevalence of abnormalities of basal, maximum effort and recovery ECG in pilots exposed to higher noise intensity (p < 0.05); e) improved hypertensive response to ergometric test in pilots with basal hypertension; f) subjects with a maximal load up to 120 W belonged prevalently to the group exposed to more intense noise (p < 0.001), while those with maximal load up to 210 W (p < 0.001) belonged to the group exposed to less intense noise. Considering that pilots are comparable for traditional cardiovascular risk factors, including age, both within the group and with the controls, the results confirm 1) that pilots could be exposed to the risk of effects on the cardiovascular apparatus, 2) that noise could be one of the risk factors and that cardiovascular effects could be related to intensity, type and length of exposure, age being the same, 3) that vascular damage is often accompanied by hearing loss even if the response of the auditory apparatus is different from the response of the cardiovascular apparatus, 4) that the postural diminution of arterial blood pressure might be a sign of a cardiovascular effect of noise. Lastly, a higher hypertensive response in hypertensive pilots suggests that basal hypertension is not reversible. Also a longer exposure to noise seems to influence the cardiovascular apparatus, causing a decrease in the response to work loads due to a lower sympathetic adaptability. The altered response of sympathetic activity to the postural modifications in the more exposed subjects and the response to lower work loads in pilots exposed to more intense noise, suggests a hypothesis of catecholamine depletion and alteration of baroceptor sensitivity as a consequence of chronic sympathetic activation due to chronic exposure to noise.

Adult↗