PubMed Health⌕ Search

Biomedical subjects

S Foskett

Publications and source records attributed to S Foskett.

3 recordsLinked to original sources

Characterization of absorbable collagen sponges as rhBMP-2 carriers.

For clinical use recombinant human bone morphogenetic protein (rhBMP-2) is soaked onto an absorbable collagen sponge (ACS) for bone regeneration. Therefore, loss of rhBMP-2 upon mechanical handling during implantation and a potential effect of the carrier on in vivo retention is of interest. The interactions between drug and carrier were looked at from the application mode and the amount of protein which can be mechanically expressed from the combination was investigated. The results indicated that rhBMP-2 binds to the collagen system. The most hydrophilic double extended homodimer showed the least binding affinity to ACS. By extending the waiting time between soaking and implantation, protein incorporation could be increased. In addition, the amount of rhBMP-2 which could be expressed was reduced by heavier ACS material and allowed for a shorter waiting period, especially at lower rhBMP-2 concentration. Crosslinking of ACS with formaldehyde led to reduced binding of rhBMP-2 to collagen either by direct hindrance of binding or reduction in swelling and number of binding sites available. Higher product pH or anion concentration enabled to increase rhBMP-2 incorporation but was limited by the potential precipitation of rhBMP-2. Despite a variety of chemical changes of ACS by ethylene oxide sterilization incorporation was not changed significantly. The in vivo release kinetics of 125I-rhBMP-2 from the collagen sponge were studied using a rat ectopic implant model. The ACS/rhBMP-2 systems tested demonstrated small, but significant differences in the in vivo retention of rhBMP-2. Consequently, it is important to have as little variability in pH, anion concentration, crosslinking and ACS mass as possible to achieve consistent or maximum binding and to avoid rhBMP-2 precipitation. Furthermore, these characteristics can be important for other in vivo applications.

Absorbable Implants↗

Characterization of absorbable collagen sponges as recombinant human bone morphogenetic protein-2 carriers.

For clinical use recombinant human bone morphogenetic protein-2 (rhBMP-2) is soaked onto an absorbable collagen sponge (ACS) for bone regeneration. Therefore, loss of rhBMP-2 upon mechanical handling during implantation and a potential effect of the carrier on in vivo retention is of interest. The interactions between drug and carrier were looked at from the application mode and the amount of protein which can be mechanically expressed from the combination was investigated. The results indicated that rhBMP-2 binds to the collagen system. The most hydrophilic double extended homodimer showed the least binding affinity to ACS. By extending the waiting time between soaking and implantation, protein incorporation could be increased. In addition, the amount of rhBMP-2 which could be expressed was reduced by heavier ACS material and allowed for a shorter waiting period, especially at lower rhBMP-2 concentration. Crosslinking of ACS with formaldehyde led to reduced binding of rhBMP-2 to collagen either by direct hindrance of binding or reduction in swelling and number of binding sites available. Higher product pH or anion concentration enabled to increase rhBMP-2 incorporation but was limited by the potential precipitation of rhBMP-2. Despite a variety of chemical changes of ACS by ethylene oxide sterilization incorporation was not changed significantly. The in vivo release kinetics of (125)I-rhBMP-2 from the collagen sponge were studied using a rat ectopic implant model. The ACS/rhBMP-2 systems tested demonstrated small but significant differences in the in vivo retention of rhBMP-2. Consequently, it is important to have as little variability in pH, anion concentration, crosslinking, and ACS mass as possible to achieve consistent or maximum binding and to avoid rhBMP-2 precipitation. Furthermore, these characteristics can be important for other in vivo applications.

Absorbable Implants↗

Bone regeneration with recombinant human bone morphogenetic protein-2 (rhBMP-2) using absorbable collagen sponges (ACS): influence of processing on ACS characteristics and formulation.

The effects of variability in three parameters (mass, cross-linking with CH2O, and EtO sterilization) of three surgically implantable absorbable collagen sponges (ACS) were studied. Sponges soaked with recombinant human bone morphogenetic protein-2 (rhBMP-2) solution were analyzed for pH, conductivity, and rhBMP-2 precipitation. A method using trinitrobenzenesulfonic acid was developed to quantify the free amino groups of the collagen sponge. With up to 240 min exposure to CH2O, the amount of free amino groups was reduced to 80%. In comparison, the denaturation temperature as determined by differential scanning calorimetry (DSC) after the sponges were soaked with phosphate-buffered saline, increased from 48 to 55 degrees C, indicating stronger interactions due to cross-linking. Subsequent sterilization with EtO caused a marked decrease in the amount of free amino groups (approximately 33% of nonsterilized controls) independent of previous CH2O treatment. However, the denaturation temperature was on average 5 degrees C lower in sterilized sponges than in nonsterilized material. In contrast to CH2O exposure, the strong reaction with EtO appeared to weaken the collagen structure. Resistance of the sponge to collagenase correlated with the degree of collagen cross-linking but was slightly reduced by sterilization. In addition, the pH of ACS soaked with water was substantially increased by sterilization. Protein precipitation was a function of pH and salt concentration but there was no effect due to collagen alone. Results indicated that ACS weight has to be limited to avoid rhBMP-2 precipitation.

Absorbable Implants↗