PubMed Health⌕ Search

Biomedical subjects

S Fukunaga

Publications and source records attributed to S Fukunaga.

At least 19 recordsLinked to original sources

Cardio-aortic operation in octogenarians.

OBJECTIVE: Aging of the population is a current phenomenon in Japan, and life expectancy at 80 years old is getting longer. So we reviewed cardio-aortic operations on octogenarians at our institution. SUBJECTS AND METHODS: Thirty-three consecutive octogenarian patients who had undergone cardio-aortic operations from 1992 to 1998 were studied. There were 14 men and 19 women. The mean age was 81.9 years. Of the 33, 19 patients (58%) were in New York Heart Association class IV, and 21 patients (64%) were operated on urgently or in emergency. The procedures undergone were operation for coronary artery disease in 17 patients, operation for valvular disease in 7 patients, operation for thoracic-aorta in 7 patients, and others in 2 patients. RESULTS: The hospital mortality rate was 27% (9 patients). However, 89% of patients experiencing hospital death were in New York Heart Association class IV preoperatively and had required an emergency/urgent operation. On the other hand, there was only one hospital death (1/12, 8.3%) among the elective patients. The statistically significant risk factors for hospital death were renal insufficiency, shock, New York Heart Association class IV, intra-aortic balloon pumping, and longer cardiopulmonary bypass time. The one-, three-, and five-year-survival rate was 73%, 68%, and 55%, respectively. Of the survivors, 77% were in class I or II. CONCLUSION: Although octogenarians' hospital mortality was still very high, the mid-term results were acceptable and the survivors' quality of life was satisfactory. These data suggested that we should operate on cardio-aortic patients before they reach a very serious state, especially in octogenarians.

Age Factors↗

Peripheral ameloblastoma with potentially malignant features: report of a case with special regard to its keratin profile.

A peripheral ameloblastoma with atypical features occurring on the left maxillary alveolar ridge of 40-year-old man is described, along with an immunohistochemical profile of its cytokeratin (CK). The lesion apparently originated from the surface gingival epithelium. The tumor nests or strands were highly cellular with a variable degree of squamous differentiation and microcyst formation. Occasional mitotic figures and dystrophic calcification, both of which are not seen in conventional ameloblastomas, were also observed. The tumor infiltrated deep into the alveolar mucosa, including the periodontal ligament, and showed histological and topographical evidence of atypism, resulting in resorption of the underlying alveolar bone. On the CK immunohistochemistry, CK19 was demonstrated in all the types of neoplastic epithelia, including microcyst-forming cells, densely packed round or spindle cells within the tumor nests, cells with squamous metaplasia, and peripheral tall columnar cells. The CK immunohistochemical findings suggest the lesion's cell of odontogenic origin; they may reflect an immature phenotypic expression of cell differentiation in the odontogenic epithelia during the tumor growth in the gingival mucosa.

Adult↗

Triple valve replacement with bileaflet mechanical valves: is the mechanical valve the proper choice for the tricuspid position?

A more durable mechanical valve may be a better choice for the tricuspid position than a bioprosthesis when the patient already has mechanical prosthesis in the left side of the heart. Eleven cases of triple valve replacement (total follow-up period, 49.5 patient years), all with mechanical valves, are reviewed to assess optimal valve selection. Nine patients had undergone a total of 12 previous cardiac surgeries. Three patients died in hospital (27.3%), but there were no late deaths among the survivors. Two cases of valve thrombosis in the tricuspid position occurred (linearized incidence: 4.04%/patient years) and 1 of these required reoperation. Because of this high incidence of valve thrombosis, the bileaflet mechanical valve is not considered to be the best choice. Even if mechanical valves are implanted in the left side of the heart, a bioprosthesis may be a better choice at the tricuspid position.

Adult↗

Repair of left ventricular rupture following mitral valve replacement concomitant with left atrial reduction procedure--intracardiac patch and extracardiac buttress suture.

Rupture of the posterior wall of the left ventricle after mitral valve replacement is a dire complication associated with a very high mortality. This study reports a successful repair of type I left ventricular rupture, which occurred after mitral valve replacement concomitant with a left atrial reduction procedure, by combination of an intracardiac patch and an extracardiac buttress suture. In a case such as this, in which hemostasis is quite difficult to establish, this combination technique is particularly effective.

Female↗

Surgical treatment of prosthetic valve endocarditis with left ventricular-aortic discontinuity: reconstruction of the left ventricular outflow tract with a xenopericardial conduit.

BACKGROUND AND AIM OF THE STUDY: Aortic prosthetic valve endocarditis (PVE) with annular destruction presents a challenge that requires techniques to eradicate the infection and correct the hemodynamic abnormality. METHODS: Between July 1, 1996 and March 31, 2000, six patients with native or PVE of the aortic valve and aortic annular destruction underwent surgical treatment. Of these patients, three (two men, one woman; mean age 71.0 years) had circumferential annular destruction of the aortic annulus, and formed the basis of this study. The microorganisms responsible for the infection were Streptococcus spp. in two patients and Staphylococcus aureus in one patient. In addition to aggressive debridement of the infected tissue, repair was achieved by reconstruction of the left ventricular outflow tract with a xenopericardial conduit and fixation of the new prosthetic valve to the conduit. RESULTS: One patient with ventricular septal perforation, multiple systemic embolism and sepsis died of low cardiac output syndrome soon after surgery. Two operative survivors were followed up for 9 and 51 months, with no late deaths. No patient has experienced recurrent infection, pericardial patch aneurysm, or prosthetic valve detachment. CONCLUSION: These operative procedures provide easy and secure fixation of the pericardial patch to the healthy tissue under excellent operative view, as well as a sturdy structure for the fixation of the new prosthesis, and complete exclusion of the abscess cavity from the blood stream.

Aged↗

Cerebral protection selection in aortic arch surgery for patients with preoperative complications of cerebrovascular disease.

OBJECTIVE: Retrograde perfusion is gaining acceptance as a means of cerebral protection, but it remains unclear how long the brain is protected and whether it is effective in patients with preoperative cerebrovascular disease. METHODS: From January 1989 to August 1999, 205 patients--118 male and 87 female patients who ranged 12 to 86 years old, mean: 65.5 years old--underwent surgery at our hospital for aortic arch aneurysm using cerebral protection. We focused on mortality, stroke incidence and perioperative risk factor between 2 groups--selective cerebral and retrograde cerebral perfusion--also studying patients with preoperative cerebrovascular disease that influenced postoperative stroke. RESULTS: The hospital mortality was 11.7% (selective cerebral perfusion group: 12%, retrograde group: 10.9%). Stroke occurred in 11 patients (5.3%), 4.7% in the selective cerebral perfusion group and 7.3% in the retrograde group. Preoperative cerebrovascular disease does not appear to be a risk factor for postoperative brain damage in aortic arch surgery. Regarding total replacement of the aortic arch, the incidence of postoperative brain damage in the retrograde group with preoperative cerebrovascular disease was higher than that in another group (p = 0.072). Cardiopulmonary bypass time and selective cerebral perfusion time in the patients with postoperative stroke were significantly longer than that in non-stroke group. CONCLUSIONS: Preoperative cerebrovascular disease did not appear to be a risk factor in postoperative neurological deficit in the selective cerebral perfusion group. Prolonged selective cerebral perfusion time and cardiopulmonary bypass time may, however, lead to brain edema and cause neurological deficit.

Adolescent↗

Left ventricular myxoma: report of a case.

Although recent advances in echocardiography have made it easier to detect cardiac tumors, left ventricular myxomas are still rare and often not found until the patient presents with a history of syncopal episodes or systemic embolization. Left ventricular myxomas are usually benign and curable; however, unreliable excision of the myxoma due to poor visualization of the left ventricular cavity can result in recurrence. To prevent recurrence, it is necessary to select the most appropriate surgical approach to excise the myxoma completely. We report herein the case of a patient in whom surgical excision of a left ventricular myxoma arising from the posterior wall of the left ventricle was successfully performed.

Diagnosis, Differential↗

Aortic dissections complicating open cardiac surgery: report of three cases.

Between June 1991 and February 1999, three patients suffered ascending aortic dissection as a complication of cardiopulmonary bypass operations with aortic cannulation at our hospital. The dissection occurred during the operation in two of the three patients and several months after the operation in one. Among a total of 2207 cardiac operations performed during this period, the incidence of perioperative ascending aortic dissection was 0.14%. In addition to visual inspection and palpation, either epicardial or transesophageal echocardiography proved extremely useful for establishing an intraoperative diagnosis of ascending aortic dissection as a complication of open cardiac operation. One of the three patients underwent closed plication but subsequently died of vital organ ischemia. In this case, failure of reapproximation of the injured intima by closed plication might have led to extension of the dissection. Despite prolonged cardiopulmonary bypass and myocardial ischemic time, graft replacement of the ascending aorta was successfully carried out in the other two patients. Thus, we believe that graft replacement of the ascending aorta should be performed for patients with extensive aortic dissection complicating an open cardiac operation.

Aged↗

Surgical treatment for graft stenosis after repair of an interrupted aortic arch: report of two cases.

We report herein two cases of patients who underwent successful reoperation for graft stenosis after repair of an interrupted aortic arch (IAA). The first patient was a 10-year-old girl who suffered from upper limb hypertension 9 years after her initial operation. Cardiac catheterization revealed a pressure gradient of 55 mmHg across the repaired arch. At reoperation, a left subclavian turndown anastomosis was performed, following which the hypertension resolved and a cardiac catheterization done 5 years later demonstrated sufficient growth of the restored arch with no significant gradient. The second patient was a 17-year-old boy who suffered from general fatigue and intermittent hypertension 12 years after his initial operation. Cardiac catheterization revealed a gradient of 60 mmHg across the repaired arch. He underwent an extraanatomic ascending to descending aortic bypass employing an additional 18-mm graft, and a postoperative cardiac catheterization showed no gradient between the ascending and descending aorta. Our experience has shown that IAA should be repaired without prosthetic grafts if possible. Although extraanatomic bypass is useful for reducing the operative risks at reoperation, a large graft should be used to avoid the need for a third operation. For young children expected to outgrow a second graft, performing an endogenous anastomosis, such as a left subclavian turndown anastomosis, should be considered as an alternative.

Adolescent↗

Tricuspid valve replacement with the St. Jude Medical valve: 19 years of experience.

OBJECTIVE: The choice of the valve substitute in the tricuspid position remains controversial. A St. Jude Medical valve is a choice of valve substitute and its lower thrombogenicity and excellent hemodynamic performance have been reported even in the tricuspid position. However, little is known of the long-term durability of the St. Jude Medical valve in the tricuspid position. Our long-term experience of tricuspid valve replacement showed the higher thrombogenicity than we had expected, therefore, this study was done to reconsider our strategy for valve choice. METHODS: This study reviewed 23 patient who underwent 25 tricuspid valve replacements with the St. Jude Medical valves from 1980 to 1997. The mean age was 40 years. Eleven patients (48%) were men. There were four in-hospital deaths (17%). The remaining 19 patients were all alive and followed from 2.2 to 19.0 years (mean 11.8 years). RESULTS: The overall survival, including hospital mortality, was 83%, 10 and 15 years after surgery. Valve thrombosis occurred in six patients. Freedom from valve thrombosis was 78 and 70%, 10 and 15 years after surgery, respectively. The linearized rate of the valve thrombosis was 2.9%/patient-years. Six patients required reoperation. The mean interval to reoperation was 9.5 years. Freedom from reoperation was 83% and 75%, 10 and 15 years after surgery, respectively. The linearized rate of the reoperation was 2.8%/patient-years. No structural valve deterioration was found. Echocardiographic study showed that the function of the St. Jude Medical valve without valve-related complications was well maintained. CONCLUSIONS: The higher thrombogenicity of the St. Jude Medical valve in the tricuspid position altered our choice of valve substitutes from the St. Jude Medical valve to a bioprosthesis which is lack of need for anticoagulant therapy except for juvenile patients who are able to maintain potent anticoagulant therapy.

Adolescent↗

Cerebral tissue oxygen saturation during percutaneous cardiopulmonary support in a canine model of respiratory failure.

Percutaneous cardiopulmonary support (PCPS) has come to be applied for cardiopulmonary resuscitation and in the management of severe respiratory failure as well as severe heart failure. We investigated cerebral tissue oxygen saturation during PCPS in a canine model of respiratory failure using near-infrared spectroscopy. Animals were mechanically ventilated with 10% oxygen to make a respiratory failure model. Perfusion with PCPS was performed via the left femoral artery and switched to that via the right axillary artery. Cerebral tissue oxygen saturation was 54.2 +/- 3.4% during PCPS via the femoral artery and was 82.3 +/- 4.6% during PCPS via the axillary artery (p = 0.001). Hepatic tissue oxygen saturation was not significantly different. LV dP/dt max increased significantly after switching to the axillary blood supply (p = 0.001). Conventional PCPS may not have the capability of supporting cerebral circulation under severe respiratory failure without organic heart disease.

Analysis of Variance↗

Eccentric roller type total artificial heart creating interatrial shunt.

Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy efficiency. We changed the left blood chamber volume of 60 ml to 40 ml and the right blood chamber volume of 53 ml to 35 ml compared with previous types. Designs of inlet and outlet ports were modified to prevent backflow. In the mock circulatory system, redesigning the blood chambers resulted in a 20% increase in energy efficiency, about a two-fold increase of cardiac output and improved durability compared to the previous type. In an animal experiment, the ERTAH operated at a driving rate of 160 rpm with a left flow rate of 6.0 L/min and a right flow rate of 5.4 L/min. Interatrial shunt flow rate was 250-400 ml/min.

Animals↗

Biocompatibility of heparin-coated extracorporeal bypass circuits: new heparin bonded bioline system.

Biocompatibility of a new type of heparin-coated cardiopulmonary bypass equipment, the Bioline, was evaluated in coronary artery bypass surgery cases. The heparin-coated (H) group (n = 15; Quadrox Bioline oxygenator/reservior and Carmeda BioMedicus BP-80 centrifugal pump) was compared with the nonheparin-coated (N) group (n = 12; uncoated, otherwise similar oxygenator, centrifugal pump, tubing, and filter set). Both groups used full systemic heparinization. The peak values of neutrophil elastase, C3a, IL-6, and IL-8 at 2 h after cardiopulmonary bypass (CPB), and C3a levels at the end of CPB and at 2 h after CPB were significantly reduced in the H group compared with those of the N group. However, no statistically significant intergroup differences were observed in thrombin-antithrombin complex, D-dimer, beta-thromboglobulin, or platelet factor-4. No significant differences were observed in hemostasis time, postoperative 12 h blood loss, required amount of blood transfusion, or intubation time. In conclusion, the Bioline demonstrated partially improved biocompatibility, in terms of leukocyte and complement activation, and proinflammatory cytokine production. However, it did not improve platelet activation, coagulation, or fibrinolysis cascade under full systemic heparinization. As a result, the clinical beneficial impact seemed to be the minimum.

Aged↗

Obstruction of St Jude Medical valves in the aortic position: significance of a combination of cineradiography and echocardiography.

BACKGROUND: Obstruction of the St Jude Medical valve (St Jude Medical, Inc, St Paul, Minn) is a rare but serious complication. METHODS: Cineradiographic and echocardiographic evaluations of aortic St Jude Medical valves were simultaneously performed on 54 patients, with no signs of prosthetic valve dysfunction late after surgery. RESULTS: Although closing angles of the leaflets corresponded closely with the manufacturer data, restricted opening of the leaflets (opening angle >/= 20 degrees ) was found in 16 (group D) of the 54 patients by means of cineradiography. The opening angles were equal to or less than 14 degrees in the other 23 patients (group N) and between 15 degrees and 19 degrees in the remaining 15 (group M). Doppler-derived transprosthetic pressure gradients were significantly higher (P =.03) and the velocity index was significantly lower (P =.003) in group D than in group N. However, no significant differences were found in those values between group N and group M. Replacement of the aortic St Jude Medical valves was performed in 5 of the 16 patients, and the remaining 11 have been followed up because of relatively low pressure gradients. The cause of restricted leaflet movement was pannus formation without thrombosis in 4 patients and valve thrombosis with pannus formation in one. CONCLUSIONS: Reduced valve orifice area and restricted opening of the leaflets resulting from excess growth of pannus probably led to obstruction of the aortic St Jude Medical valves. A combination of cineradiography and echocardiography makes it possible to provide an accurate and detailed diagnosis of obstruction of the valve.

Adolescent↗

Plasma exchange for hyperbilirubinemia following implantation of a left ventricle assist system: a case report.

A 49-year-old patient with end-stage dilated cardiomyopathy underwent implantation of a left ventricular assist system (LVAS). Although the systemic circulation seemed to be improved, the serum total bilirubin (Tbili) level increased sharply in the early postoperative period (preoperative Tbili, 5.7 mg/dl; postoperative day 3, 33.6 mg/dl). Plasma exchange (PE) was performed 7 times from postoperative day 4, and the Tbili level decreased to 16.3 mg/dl by postoperative day 11. Thereafter, serum Tbili normalized concomitant with improved circulatory condition. The cause of the hyperbilirubinemia was considered to be temporary right ventricular dysfunction or hepatic sinusoid endothelial dysfunction. The liver function was recoverable, so PE had been effective in this case. Unfortunately, the patient suffered a midbrain infarction and ultimately died. From this experience, PE is recommended if it is judged that liver function can be preserved and circulation is adequate, but its implementation should not be delayed. It is essential that LVAS is implanted before damage occurs to end-organ function and thus prevent hyperbilirubinemia.

Cardiomyopathy, Dilated↗

[Hemodynamic assessment of the Carpentier-Edwards pericardial valve compared with the St. Jude Medical valve in the aortic position using dobutamine-stress echocardiography].

To assess the hemodynamic performance of the prosthetic valve in the aortic position, we examined dobutamine-stress echocardiography (DSE) to the patients underwent AVR with CEP valve or SJM valve. In 23 mm size, there were no significant differences between CEP group and SJM group in Peak velocity of the aortic jet (PV), peak pressure gradient (PPG) and effective orifice area (EOA). On the other hand, in 21 mm size, PV and PPG of the CEP group were significantly lower than those of the SJM group after DSE. The EOA of the CEP group was significantly larger than that of the SJM group after DSE. Our results suggest that the hemodynamic function of the CEP valve is superior to that of the SJM valve especially in small aortic annuli.

Aged↗

Newly designed eccentric roller type total artificial heart.

We have produced an eccentric roller type total artificial heart (ERTAH). As the first step in the development of this ERTAH, we conducted simulations such as a numerical simulation, a mock test, and an acute animal experiment using DeBakey roller pumps to analyze the left-right balance during its operation. The next step was redesigning the blood chambers to improve energy efficiency and implanting the ERTAH with an interatrial shunt into an animal for evaluation of the in vivo performance of the device. In the simulations, shunt flow through the bronchial arteries was approximately 500-600 ml/min, and the interatrial resistance was varied from 2.9-7.7 mmHg.min/liter. Redesigning the blood chambers resulted in the mock test in a 20% increase in energy efficiency, about a two-fold increase in cardiac output and improved durability compared to the previous type in the mock test. In the animal experiment the ERTAH operated with a left flow rate of 6.0 liters/min and a right flow rate of 5.4 liters/min. The interatrial shunt flow rate was 250-400 ml/min. Creating an interatrial shunt is a useful method for balancing the blood flow between the left and right heart of the ERTAH. A decrease in friction resistance and the prevention of backward flow resulted in an increase in energy efficiency, cardiac output, and improved durability, in spite of downsizing the blood chambers.

Animals↗