PubMed Health⌕ Search

Biomedical subjects

S Furlanetto

Publications and source records attributed to S Furlanetto.

At least 19 recordsLinked to original sources

Simultaneous effect of cyclodextrin complexation, pH, and hydrophilic polymers on naproxen solubilization.

The effect of pH variation on complexation and solubilization of naproxen (pK(a) 4.2) with natural betaCyclodextrin (betaCyD) and various neutral, cationic and anionic betaCyD-derivatives has been investigated. The combined effect of pH variation and hydrophilic polymer addition on CyD solubilizing and complexing efficiency has also been determined. Phase-solubility analysis in buffered aqueous solutions (pH from 1.1 to 6.5) was used to study the interaction of the drug with each CyD, in the presence or not of the water-soluble polymer. A clear influence of the substituent type was observed, the methylderivative being the most efficient agent; on the contrary, unexpectedly, no influence of the CyD charge in the interaction with the ionizable drug was detected. As expected, total drug solubility increased with increasing pH; however, the solubility increment with respect to drug alone obtained by CyD complexation progressively decreased, with a parallel reduction of the complex stability, attributed to the reduced affinity of charged drug for the hydrophobic CyD cavity. The addition of the polymer in part counterbalanced the destabilizing effect obtained with increasing pH, by improving the CyD complexation power towards naproxen. In particular, the presence of PVP allowed an increase of the complex stability constant with hydroxypropyl betaCyD up to 60% with respect to the corresponding drug-CyD binary system. Therefore, the combined strategy of pH control and polymer addition to the CyD complexing medium can be successfully exploited to improve naproxen solubilization and reduce the amount of CyD needed. The construction of theoretical drug solubility curves as a function of pH for any given CyD and polymer concentration enables selection of the best experimental conditions for obtaining the desired drug solubility value.

Hydrogen-Ion Concentration↗

Interaction of naproxen with ionic cyclodextrins in aqueous solution and in the solid state.

The possible role of the cyclodextrin charge in the interaction with an acidic drug such as naproxen (pKa 4.8) has been evaluated. Sulfobutylether-beta-cyclodextrin (SBE-betaCyd) and trimethylammonium-beta-cyclodextrin (TMA-betaCyd) were selected as, respectively, anionically and cationically charged carriers and their performance was compared with that of the parent beta-cyclodextrin (betaCyd) and of its methyl-derivative (Me betaCyd) previously found as the best partner for the drug. Interactions in solution were investigated by phase-solubility, fluorescence and circular dichroism analyses. Equimolar drug-carrier products prepared by different techniques (blending, cogrinding, sealed-heating, colyophilization) were characterized by differential scanning calorimetry and X-ray powder diffractometry and tested for drug dissolution properties. Anionic charges of SBE-betaCyd did not negatively influence interactions in unbuffered aqueous solutions (pH approximately 5) with the acidic drug. In fact, it was a very effective carrier, exhibiting solubilizing and complexing properties considerably better than the parent betaCyd and comparable to those of Me betaCyd. On the contrary, the positive charges of TMA-betaCyd did not favour interactions with the counter-ionic drug (despite the presence of about 60% ionised drug) and it was less efficacious also than native betaCyd. Therefore, the role of the Cyd charge on the complexing and solubilizing properties towards naproxen was not important whereas other factors, such as steric hindrance effects and favourable hydrophobic interactions were significant in determining the drug affinity for the Cyd inclusion. Solid state studies evidenced similar amorphizing properties of both charged Cyds towards naproxen. On the other hand, dissolution tests, in agreement with solution studies, showed that all products with SBE-betaCyd exhibited significantly better dissolution properties than the corresponding ones with TMA-betaCyd. A clear influence of the preparation method of drug-Cyd solid systems on the performance of the end product was also observed. Colyophilization was the most effective technique, followed by the cogrinding one. Colyophilized product with SBE-betaCyd allowed a 10-times increase in drug dissolution efficiency (D.E.) (with respect to the five-times increase obtained with the corresponding coground product) and a reduction of t(50%) from about 60 min (for the coground product) to less than 2 min.

Cyclodextrins↗

Determination of stability constant values of flurbiprofen-cyclodextrin complexes using different techniques.

Three new experimental approaches for calculating the stability constant (K(st)) of complexes of flurbiprofen with natural beta-cyclodextrin (betaCyd) and the hydroxyethyl- (HEbetaCyd) and the methyl- (Me betaCyd) derivatives were tested and compared to the classic phase-solubility procedure: (a) the membrane permeation technique through a lipophilic synthetic membrane permeable to the drug but not to the Cyd molecules, by analysing the permeation profiles with a non-linear least-squares method; (b) the affinity capillary electrophoresis (ACE) technique, where K(st) were calculated from the relationship between Cyd concentration in solution and drug electrophoretic mobility, using three different linear plotting methods; (c) the molecular modeling technique, based on the relationship between the docking energies and the experimental K(st) values. The study allowed evaluation of the advantages and limits of each examined method, providing a useful guide for the choice of the most suitable one depending on the kind of host-guest system to be investigated. The K(st) values obtained with the various techniques were rather different, probably due to the very different experimental conditions required by each one. However, all the methods indicated the methyl-derivative as the most powerful complexing agent for the drug, showing the general trend: K(st)(Me betaCyd)>>K(st)(HEbetaCyd)>K(st)(betaCyd). Only in the case of the ACE method was an inversion of the trend found between HEbetaCyd and betaCyd; this was probably due to the lower molecular weight of the natural Cyd, which, in this case, became more important in determining the complex electrophoretic mobility than the different affinity of the drug for these two Cyds.

Chemistry, Pharmaceutical↗

Optimization of glibenclamide tablet composition through the combined use of differential scanning calorimetry and D-optimal mixture experimental design.

A systematic analysis of the influence of different proportions of excipients on the stability of a solid dosage form was carried out. In particular, a d-optimal mixture experimental design was applied for the evaluation of glibenclamide compatibility in tablet formulations, consisting of four classic excipients (natrosol as binding agent, stearic acid as lubricant, sorbitol as diluent and cross-linked polyvinylpyrrolidone as disintegrant). The goal was to find the mixture component proportions which correspond to the optimal drug melting parameters, i.e. its maximum stability, using differential scanning calorimetry (DSC) to quickly obtain information about possible interactions among the formulation components. The absolute value of the difference between the melting peak temperature of pure drug endotherm and that in each analysed mixture and the absolute value of the difference between the enthalpy of the pure glibenclamide melting peak and that of its melting peak in the different analyzed mixtures, were chosen as indexes of the drug-excipient interaction degree.

Calorimetry, Differential Scanning↗

Development of a chromatographic bioreactor based on immobilized beta-glucuronidase on monolithic support for the determination of dextromethorphan and dextrorphan in human urine.

We here reported the development and application of an immobilized enzyme reactor (IMER) based on beta-glucuronidase to the on-line determination of urinary molar ratios of dextromethorphan (DOMe)/dextrorphan (DOH) for the assessment of the metabolic activity of CYP2D6, a genetically variable isoform of cytochrome P-450 (CYP). beta-Glucuronidase was immobilized on an HPLC monolithic aminopropyl silica support. Catalytic activity and stability of the chromatographic reactor were evaluated using 8-hydroxyquinoline glucuronide (8-HQG) as substrate. The IMER was coupled through a switching valve to a reversed-phase column (C8) for the simultaneous determination of dextromethorphan and its main metabolite dextrorphan. On purpose a selective reversed-phase ion pair HPLC method coupled with fluorescence detection was developed. Urine samples were first centrifuged to remove insoluble materials and then aliquots of the supernatants were injected into the coupled-column analyser. Linearity, precision and accuracy of the method were established. The method reliability was verified by comparing our data with previous data of a phenotyping study carried out by the Poison Control Centre of Pavia-Clinical Toxicology Division.

Chromatography, High Pressure Liquid↗

Micellar electrokinetic chromatography for the simultaneous determination of ketorolac tromethamine and its impurities. Multivariate optimization and validation.

A simple, fast and selective micellar electrokinetic chromatographic (MEKC) method for the simultaneous assay of ketorolac tromethamine and its known related impurities (1-hydroxy analog of ketorolac, 1-keto analog of ketorolac and decarboxylated ketorolac), in both drug substance and coated tablets, is described. The compounds were detected at 323 nm, and flufenamic acid (FL) and tolmetin (TL) were chosen as internal standards to quantify ketorolac tromethamine and impurities, respectively. The multivariate optimization of the experimental conditions was carried out by means of the response surface study, considering as responses the resolution values and analysis time. The optimized background electrolyte (BGE) consisted of a mixture of 13 mM boric acid and phosphoric acid, adjusted to pH 9.1 with 1 M sodium hydroxide, containing 73 mM sodium dodecyl sulfate (SDS). Optimal temperature and voltage were 30 degrees C and 27 kV. Applying these conditions, all compounds were resolved in about 6 min. The related substances could be quantified up to the 0.1% (w/w) level. Validation was performed, either for drug substances and drug product, evaluating selectivity, robustness, linearity and range, precision, accuracy, detection and quantitation limits and system suitability.

Anti-Inflammatory Agents, Non-Steroidal↗

How experimental design can improve the validation process. Studies in pharmaceutical analysis.

A critical discussion about the possibility of improving the method validation process by means of experimental design is presented. The reported multivariate strategies concern the evaluation of the performance parameters robustness and intermediate precision, and the optimisation of bias and repeatability. In particular, accuracy and precision improvement constitutes a special subset of experimental design in which the bias and the relative standard deviation of the assay are optimised. D-optimal design was used in order to plan experiments for this aim. The analytical methods considered were capillary electrophoresis, HPLC, adsorptive stripping voltammetry and differential pulse polarography. All methods were applied to real pharmaceutical analysis problems.

Adsorption↗

Lipases for biocatalysis: development of a chromatographic bioreactor.

The development of a new chromatographic reactor based on immobilized Candida rugosa lipase (CRL) is described. The chromatographic system has been used to evaluate the rate differences by which the product enantiomers of esterolytic reactions catalyzed by immobilized CRL are obtained. The method has been applied to a series of racemic 2-aryloxyalkanoic acids and isosteric analogous methyl esters and to some non-steroidal antiinflammatory drugs 2-arylpropanoic acids methyl esters in order to study the structure effects on reaction rate and enantioselectivity. Lipase from C. rugosa has been non-covalently and covalently immobilized on HPLC chromatographic silica supports to develop an immobilized enzyme reactor (IMER). The reactor was connected through a switching valve to an analytical reversed-phase column, which was used for the on-line determination of the hydrolysis rate by peak area integration. The enantiomeric excess of the hydrolytic reaction products was determined off-line on a CSP utilizing immobilized penicillin G acylase (PGA-CSP).

Bioreactors↗

Optimization of dissolution test precision for a ketoprofen oral extended-release product.

An example of application of experimental design methodologies to the set up of dissolution test conditions for a new ketoprofen oral extended-release dosage form is presented. The aim of the work was to find the best experimental conditions, using a USP apparatus 2 (paddle), for maximizing the method precision as degree of repeatability. The considered factors mainly influencing the dissolution test results were pH and volume of dissolution medium, and paddle stirring speed. Two distinct 4-run Plackett-Burman designs were carried out: one at gastric and the other at intestinal pH values. Each run was performed in triplicate in order to calculate the standard deviations of the drug dissolution efficiency at 60 and 120 min, selected as responses to be minimized. Optimum conditions to carry out the dissolution test were: 900 ml volume of dissolution medium and 70 rpm paddle stirring speed for both environments and pH 1 and 5.5, for the gastric and intestinal environment, respectively.

Administration, Oral↗

Characterization of physicochemical properties of naproxen systems with amorphous beta-cyclodextrin-epichlorohydrin polymers.

Ground mixtures of naproxen with amorphous beta-cyclodextrin-epichlorohydrin soluble (betaCd-EPS) or insoluble cross-linked (betaCd-EPI) polymers were investigated for both solid phase characterization (Differential Scanning Calorimetry, powder X-ray Diffractometry) and dissolution properties (dispersed amount method). The effect of different grinding conditions and of drug-to-carrier ratio was also evaluated. Co-grinding induced a decrease in drug crystallinity to an extent which depended on the grinding time, and was most pronounced for the cross-linked insoluble polymer, particularly in combinations at the lowest drug content. Both cyclodextrin polymers were more effective in improving the naproxen dissolution properties, not only than the parent betaCd but also than hydroxyalkyl-derivatives, and their performance was almost comparable to that of methyl-derivatives, previously found as the best carriers for naproxen. Dissolution efficiencies of naproxen from physical mixtures with betaCd-EPS, thanks to the high water solubility of this Cd-derivative, were up to three times higher than those from the corresponding products with betaCd-EPI. However this difference in their performance became much less evident in co-ground products and tended to progressively diminish with increasing the polymer content in the mixture, according to the better amorphizing power shown by betaCd-EPI during the co-grinding process. The 10/90 (w/w) drug-carrier co-ground products exhibited the best dissolution properties, giving dissolution efficiencies about 30 times higher than that of naproxen alone.

Anti-Inflammatory Agents, Non-Steroidal↗

Validation of a RP-LC method for the simultaneous determination of isoniazid, pyrazinamide and rifampicin in a pharmaceutical formulation.

A simple and accurate liquid chromatographic method was developed and validated for estimation of isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF) in combined dosage forms. Drugs were chromatographed on a reverse phase C18 column using a mobile phase gradient and monitored at the corresponding maximum of each compounds. Peaks were identified with retention time as compared with standards and confirmed with characteristic spectra using diode-array detector. Solution concentrations were measured on a weight basis to avoid the use of an internal standard. The method does not require any specific sample preparation except the use of a guard column. The method is linear (r(2)>0.999), precise (RSD%: 0.50% for ISN, 0.12% for PYR and 0.98% for RIF), accurate (overall average recovery yields: 98.55% for ISN, 98.51 for PYR and 98.56% for RIF) and selective. Due to its simplicity and accuracy the method is suitable for routine quality control analysis of antitubercolosis combination dosage form.

Antitubercular Agents↗

Validation of a LC method for the analysis of oxaliplatin in a pharmaceutical formulation using an experimental design.

A rapid and sensitive RP-HPLC method with UV detection for routine control of oxaliplatin in a pharmaceutical formulation (Eloxatin) was developed. Quantitation was accomplished with the internal standard method. The procedure was validated by linearity (correlation coefficient=0.999948), accuracy, robustness and intermediate precision. Experimental design was used during validation to calculate method robustness and intermediate precision. For robustness test three factors were considered: percentage v/v of acetonitrile, flow rate and temperature; an increase in the flow rate results in a decrease of the drug found concentration, while the percentage of organic modifier and temperature have no important effect on the response. For intermediate precision measure the considered variables were: analyst, equipment and days. The RSD value (2.27%, n=24) indicated a good precision of the analytical method.

Antineoplastic Agents↗

Optimization and validation of a CZE method for rufloxacin hydrochloride determination in coated tablets.

A simple and rapid capillary electrophoresis method with UV detection was developed and validated for the determination of rufloxacin hydrochloride in coated tablets. An experimental design strategy (Doehlert design and desirability function) allowed the analytical parameters to be simultaneously optimized in order to determine rufloxacin hydrochloride with high peak area/migration time ratio, good efficiency and short analysis time. Optimized analyses were run using boric acid 0.10 M adjusted to pH 8.8 as BGE and setting voltage and temperature at 18 kV and 27 degrees C, respectively. Pefloxacin mesylate was used as internal standard and run time was about three minutes. The method was validated for the drug substance and the drug product according to the ICH3 guidelines. Robustness was tested by experimental design using an eight-run Plackett-Burman matrix.

Anti-Infective Agents↗

Improving gas chromatographic determination of residual solvents in pharmaceuticals by the combined use of headspace solid-phase microextraction and isotopic dilution.

Cyclohexane and toluene were gas chromatographically determined via headspace solid-phase microextraction both in ketoprofen drug substance and ketoprofen capsules by a procedure relying on isotopic dilution (ID), an analytical tool derived from mass spectrometry (MS). This approach, using an internal standard method, gave mean precision and accuracy (RSD 2.56%, 2.97% and bias 0.21%, -0.99% for cyclohexane and toluene, respectively) not obtainable by the more commonly used external standard ones in the presence of real sample matrices. Optimisation of the operative conditions was also supported by experimental design. More generally, the proposed method, exploiting ID without resort to the costly MS instrumentation, could be recommended whenever opportune deuterated analogues of the target analytes and GC capillary columns able to separate all the peaks involved are ready available on the market.

Calibration↗

LC coupled to ion-trap MS for the rapid screening and detection of polyphenol antioxidants from Helichrysum stoechas.

Liquid Chromatography-Ion Trap Mass Spectrometry with an atmospheric pressure chemical ionization (APCI) interface in the negative and positive-ion modes in parallel to UV-diode-array detection (DAD), was applied for the rapid detection/characterization in crude extracts of the water-soluble antioxidant phenolics from Helichrysum stoechas. APCI-MS provides unequivocal molecular weight data of these compounds and useful information about their structures (diagnostic fragments ions), which were confirmed by the UV-DAD fingerprints. This combined approach allows the identification of ten constituents, including the three naturally occurring isomers of caffeoylquinic acid (CGAs), namely neo-chlorogenic acid, chlorogenic acid and crypto-chlorogenic acid, 2 isomeric dicaffeoyl quinic acids, 2 isomeric naringenin glucosides, quercetin, kaempferol and apigenin glucosides and a tetrahydroxychalcone-glucoside. The water-soluble extract from H. stoechas, standardized in both total polyphenol and kaempferol-3-glucoside content, exhibits strong antioxidant activity in vitro when tested in both artificial membrane systems (phosphatidylcholine liposomes) and in a cell model (rat erythrocytes).

Animals↗

Optimisation and validation of a capillary electrophoresis method for the simultaneous determination of diazepam and otilonium bromide.

A simultaneous assay of diazepam and otilonium bromide in coated tablets by capillary zone electrophoresis (CZE) was developed. The influence of various parameters (voltage, temperature, buffer concentration and pH, ethanol percentage) on analysis time and on the theoretical plates of the two peaks was investigated by means of experimental design. A response surface study was carried out by means of a 27-run D-optimal matrix. The best background electrolyte was found to be 0.13 M, pH 2.9 Britton-Robinson buffer, containing 10% v/v ethanol. Other optimised parameters were voltage (30 kV) and temperature (30 degrees C). The UV detector for quantitation of otilonium bromide and diazepam was set at 280 nm and 230 nm, respectively. Procaine hydrochloride was used as internal standard and run time was less than five minutes. Validation was performed, for drug substance and drug product, according to ICH3 guidelines. For drug product the recovery for otilonium bromide and diazepam ranged from 98.3% to 101.2% and from 97.1% to 99.0%, respectively; the RSD values found for otilonium bromide and diazepam ranged from 2.4% to 3.0% and from 1.1% to 4.5%, respectively.

Calcium Channel Blockers↗

Validation of a LC method for the analysis of zafirlukast in a pharmaceutical formulation.

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for estimation of zafirlukast in a pharmaceutical formulation. Assay samples were extracted utilizing acetonitrile. Drug and internal standard were chromatographed on reversed-phase C18 columns, using mixtures of acetonitrile/water and the eluents were monitored at different wavelengths. The method was validated statistically for its linearity, accuracy, robustness and precision. Experimental design was used during validation to evaluate method robustness and for the determination of intermediate precision. Factors examined for statistical approaches include laboratory, day, analyst, instrument, different percentage of organic modifier, temperature, wavelength and flow-rate. Due to its simplicity and accuracy, the method may be used for routine quality control analysis.

Anti-Asthmatic Agents↗

Design of experiments for capillary electrophoretic enantioresolution of salbutamol using dermatan sulfate.

Statistical experimental design was used for the optimization and for robustness evaluation of a capillary electrophoretic method developed for the enantioresolution of salbutamol. Dermatan sulfate was used as chiral selector. The goal of the study was to obtain an efficient and fast separation. An eight-run Plackett-Burman matrix was used during the optimization process for the screening of the factors and to adjust the experimental domain under study. Response surface methodology was adopted after the screening phase to obtain information about how the factors percentage of chiral selector, pH and voltage affected the considered responses resolution and analysis time. The Derringer desirability function, which makes it possible to combine results obtained for properties measured on different scales, was used to simultaneously optimize the two responses. Robustness testing was carried out using a Plackett-Burman matrix. The method was found robust as regards the response resolution while voltage and chiral selector were found to be critical factors for the robustness of analysis time response. The proposed CE method permitted the complete enantioseparation of racemic salbutamol and was applied to its chiral resolution in spiked urine samples.

Adrenergic beta-Agonists↗