PubMed Health⌕ Search

Biomedical subjects

S G Connors

Publications and source records attributed to S G Connors.

3 recordsLinked to original sources

CT-targeted irradiation of the breast and internal mammary lymph nodes using a 5-field technique.

PURPOSE: To develop an effective and resource-efficient radiotherapy technique to treat the breast and regional nodes, including the ipsilateral internal mammary nodes. METHODS AND MATERIALS: Eighty female patients who underwent MRI scans for a variety of indications had coronal, T1-weighted images of the chest performed to determine the position of the internal mammary chain (IMC). Based on these results, a 5-field treatment technique was developed that would include the breast, supraclavicular fossa, and ipsilateral IMC, while maintaining a low dose to the heart, lungs, and contralateral breast. This technique was implemented in a cohort of 13 patients. RESULTS: The lateral position of the right and left IMC were measured in three cephalo-caudad positions: at the clavicular heads, upper manubrium, and midsternum (at the 2nd/3rd rib interspace). The mean lateral separation between the right and left IMC chains at each level (and 95% confidence interval) at each level were 5.8 cm (4.67-7.00), 5.6 cm (4.49-6.73), and 5.9 cm (4.66-7.19), respectively. Treatment was delivered to 13 patients using a 5-field technique, with tangential photon fields for the breast, anterior and posterior supraclavicular/axillary field, and a matching anterior electron field. Three-dimensional treatment planning of a representative case confirmed adequate coverage of the planning target volume (PTV). The median dose to the whole heart was 10 Gy, and 20% of the ipsilateral lung received more than 20 Gy. Seven of the 13 patients treated experienced moist desquamation at the junction of the electron field and breast tangents, and 1 patient had persistent ulceration at 3 months' follow-up. CONCLUSION: The 5-field technique described in this paper provides good coverage to the breast and regional nodes with acceptable toxicity, and without requiring three-dimensional treatment planning or intensity-modulated radiotherapy techniques.

Axilla↗

Performance characteristics of a widely used orthovoltage x-ray therapy machine.

Experimental results sufficient to provide a data base for the Philips RT 250 x-ray machine are presented. A representative selection of operating conditions covering the working range of the machine from 75 to 250 kVp, were used. Beam quality, depth dose data, field flatness, and filtration characteristics were studied, and selected results are reported.

Humans↗