PubMed Health⌕ Search

Biomedical subjects

S G Coupland

Publications and source records attributed to S G Coupland.

At least 37 records · Page 2Linked to original sources

A comparison of oscillatory potential and pattern electroretinogram measures in diabetic retinopathy.

Both basic and clinical electrophysiological investigations have established that the oscillatory potentials (OP) and pattern electroretinogram (PERG) appear to originate from retinal sites that are in proximity. The OPs, subcomponents of the flash ERG, have been shown to reflect disturbances in retinal circulation, and OP amplitude attenuation or loss may be a distinctive feature of diabetic retinopathy. The PERG has been shown to be abnormal in diseases of the optic nerve and ganglion cell body. Thus its relative sensitivity for detection of electroretinal abnormalities in diabetic retinopathy is in question. This study assessed the sensitivity of ERG and OP measures in their detection of abnormalities of electroretinal function in diabetic patients referred to our laboratory. Thirty-five adult Type I patients were studied: 21 with background retinopathy (BR group), 14 with no evidence of background retinopathy (No BR group), and 25 normal control subjects. Monocular OPs were recorded to full-field ganzfeld stimulation at four stimulus intensities. PERGs were obtained from checkerboard pattern reversal stimulation (check-size = 30' arc). Peak-to-peak amplitude and peak implicit time measures of PERGs and OPs were obtained. Subsequent multivariate analysis demonstrated significant differences between normals and diabetic patients, including diabetics with no clinical evidence of retinopathy. In addition, the OP and PERG implicit times appear to be unaffected while OP and PERG amplitudes were diminished in patients with background retinopathy. Only OP amplitudes were found to be significantly diminished in diabetic patients with no photographic evidence of background retinopathy. The PERGs were normal in these patients. Overall, the OP amplitude measures were more sensitive than PERG measures in detecting abnormalities in patients with no retinal photographic evidence of background retinopathy.

Adult↗

Visual evoked potentials, intracranial pressure and ventricular size in hydrocephalus.

Hydrocephalus in the newborn is frequently seen associated with perinatal asphyxia, birth trauma, or intracranial hemorrhage. Hydrocephalus produces enlargement of the cerebral ventricles and raised intracranial pressure secondary to increases in the amount of cerebrospinal fluid. In this study the relationship between the visual evoked potential and ventricular size in infantile hydrocephalus was investigated. Statistical analysis was used to define them and the role of the visual evoked potential in the clinical and structural assessment of infantile hydrocephalus. The results of these investigations demonstrated a significant relationship between ventricular size and evoked potential parameters and confirmed the usefulness of the flash visual evoked potential examination in the assessment of infants with hydrocephalus.

Cerebral Ventricles↗

Maturational topography of the visual evoked potential in fetal lambs.

The normal maturational course of the visual evoked potential (VEP) in human newborns and infants is well documented. Unfortunately, there is a paucity of data about VEP maturation in the 'normal' preterm infant. Since this population is at risk to develop many abnormalities affecting the VEP (intraventricular hemorrhage, hydrocephalus, and retinopathy of prematurity), one must question whether such VEP data collected from this group is representative of normal maturation. To provide normative parametric developmental data we have been studying VEP development in fetal lambs. Six fetal lambs between 105 and 120 days gestational age were externalized and surgically instrumented with subcutaneous recording electrodes placed over the occipital and parietal regions. High-intensity light-emitting diodes (LEDs) externalized fiberoptic cables were secured adjacent to the orbit. from 108 to 141 days gestation, fetal VEPs were recorded in response to bright flash stimulation and the maturational topography was investigated. Over the occipital regions, the emergence of major positivities at P400 and P650 were observed beginning around 120 days gestation. Over the parietal area, the emergence of P200 and P500 components was observed by 128 days gestation. The latency-maturation functions revealed that the slope of the parietal function was steeper than the occipital counterpart, suggesting that the maturation of parietal neurons occurs at a faster rate than neuronal development in the occipital regions.

Animals↗

Ultra-low-dose routine pediatric radiography utilizing a rare-earth filter.

Clinical evaluation of the usefulness of primary beam filtration with erbium to achieve marked reductions in radiation exposure and dosage was undertaken. We evaluated 250 routine pediatric radiographic and 100 contrast examinations. An additional 52,727 radiographic and 4745 fluoroscopic examinations were analyzed prospectively by evaluation of subjective film quality. Radiation exposure and dosage reductions ranged from 57% at 50 kVp to 36% at 80 kVp and 39% at 120 kVp. These reductions were obtained in addition to those previously attained by using a 600-speed gadolinium oxysulphide screen/film system (Trimax 12, XDL). The erbium filter requires that the tube current be increased to approximately double that without the filter (in the most commonly used range of 60-100 kVp). However, tube loading is already so low with the 600 system that this effect on wear is considered inconsequential. This ultra-low-dose rare-earth beam filter and screen/film combination results in films with no demonstrable loss of overall quality, plus a subjective slight improvement in contrast definition for iodine and barium contrast studies. The addition of erbium foil beam filtration to existing rare-earth screen/film technology results in what is currently the ultimate in low-dose conventional radiographic imaging.

Child↗

CAMPS: computer-automated metacarpophalangeal profile system.

The metacarpophalangeal profile (MCP) pattern has been proven useful in describing individuals with genetic and nongenetic syndromes. However, the measurement of the 19 bone lengths is a tedious procedure requiring use of hand vernier calipers, detailed normative data to be looked up in extensive tables, hand calculator, and manual graphing techniques. Presently there are no reports of microcomputer-automated systems for the accurate measurement, recording, analysis, and graphing of MCP profiles. We describe a computer-automated metacarpophalangeal profile system (CAMPS) that will assist in the derivation of the MCP profile. This program allows the user to select different program routines that perform the functions necessary for MCP profile construction. The "data acquisition module" (DAM) assists in bone length measurement from contact prints of hand radiographs and stores the 19 measurements on a floppy disk. The "standardization analysis module" (SAM) then compares the 19 measurements to age- and sex-matched normal data and converts the raw data to z-score values. The "Pearson product-moment correlation module" (PPM) generates a correlation coefficient describing the degree of similarity between the two hands measured and graphically illustrates the resulting scatterplot. The "MCP plotting module" (MCPM) provides a graphic plot of the 19 bones in either transverse rows or phalangeal rays on a dot-matrix printer or X-Y plotter.

Bone and Bones↗

The pattern electroretinogram in optic nerve demyelination.

The pattern electroretinogram (PERG) is probably generated by the ganglion cell layer of the retina whose axons constitute the conductive fibres of the optic nerves. A study was undertaken of the PERG in a group of patients with clinically definite multiple sclerosis who had suffered optic nerve demyelination to assess the value of recording the PERG as a method for electrophysiological determination of optic nerve dysfunction. Pattern visual evoked potentials (PVEP) were simultaneously recorded, each eye being stimulated separately, and four different check sizes were used. Although individual patients showed PERG abnormalities the results as a group showed no significant difference from the normal population so far as latency or amplitude of the PERG was concerned. Thus we conclude that the PERG, while an interesting measurement, does not satisfactorily reflect optic nerve dysfunction. Further, our results indicate that it is not such a useful measure as the pattern visual evoked response for detecting optic nerve disease.

Adolescent↗

Flash electroretinogram abnormalities in patients with clinically definite multiple sclerosis.

We studied the flash electroretinograms (ERGs) of 105 patients with multiple sclerosis who were divided into four groups. The first group had no history or clinical evidence of optic nerve dysfunction, the second and third groups had either left or right optic nerve disease respectively, and the fourth group had historical or clinical evidence of bilateral optic nerve disease. Statistical analysis of the data using analysis of variance (ANOVA) showed that the group of patients with no history or clinical evidence of optic nerve disease had no significant difference from the control group for their peak b-wave implicit times but the other three groups were significantly delayed on the affected side(s). Using the Mann-Whitney U-test we found all four patient groups had significantly greater absolute interocular latency differences from the control group. The electroretinal contribution to flash VEP delay was also investigated. In those patients with unilateral or bilateral optic nerve disease we found that in 14-31% of those patients with flash VEP delay there was also abnormal prolongation of the ERG b-wave. These results confirm a high incidence of retinal dysfunction in multiple sclerosis patients and may suggest that transynaptic degeneration of retinal structures occurs in optic nerve demyelination. The significant absolute interocular latency difference in particular may provide another electrophysiological parameter to establish a diagnosis of multiple sclerosis in suspect cases.

Diagnosis, Differential↗

Orientation-specific visual evoked potential deficits in multiple sclerosis.

Checkerboard pattern reversal visual evoked potentials (VEPs) have proved useful in the confirmation of optic nerve disease in patients with multiple sclerosis (MS). Recently evidence of orientation-specific loss in contrast sensitivity and the presence of orientation-specific visual evoked potential (VEP) deficits in MS patients has been obtained using sinusoidal gratings as stimuli. This study reports the presence of orientation-specific VEP delay in MS using the conventional checkerboard pattern presented in two orientations: normally oriented (check condition) or diagonally oriented (diamond condition). Peak latency values of the N70 and P100 components of the VEP were statistically analyzed using appropriate ANOVA and nonparametric statistics. As a group of MS patients showed significant VEP delays under check and diamond pattern conditions. However, individual subject analysis revealed that about 20% of the MS population show VEP delay to only one pattern orientation. It was shown that by including a diamond pattern condition the diagnostic yield of VEP delay in these clinically definite MS patients was increased 11% over that obtained with check stimulation alone.

Electroretinography↗

Multiple regression analysis of diagnostic predictors in optic nerve disease.

Demyelination is assumed to be the cause of the majority of cases of isolated optic neuritis. Because of the importance of establishing the presence of optic nerve dysfunction in patients suspected of having multiple sclerosis several new indices of optic nerve conduction have been reported including the visual evoked potential, the edge-light pupil cycle time, and the Pulfrich test. These measures purport to detect optic nerve dysfunction but with varying degrees of success. This study of 93 patients with clearly documented previous optic neuritis was conducted to determine the statistical relationship between these three measures and other clinical diagnostic indices for detection for previous optic nerve disease and the utility of the diagnostic predictors taken individually, and in combination. The other indices used were the presence of detectable optic atrophy, color vision defect and the presence of a relative afferent pupillary defect. The variables were submitted to linear stepwise multiple regression analysis which indicated that the presence of optic atrophy, defective color vision and prolonged pupil cycle time when used in combination provided the most useful diagnostic prediction of previous optic neuritis in this group of patients. The addition of visual evoked potentials, the Pulfrich test or presence of a relative afferent pupillary defect did not significantly increase predictive reliability.

Adolescent↗

Abnormal electroretinograms and visual evoked potentials in chronic papilledema using time-difference analysis.

Visual function is usually considered to be normal in papilledema. We report previously undescribed abnormalities in the electroretinograms (ERG) and visual evoked potentials (VEP) of two patients with chronic papilledema. The steady-state latencies of the ERG and VEP were calculated using time-difference analysis. The ERG was abnormal under both scotopic (slow) and photopic (fast) flicker conditions, but the VEP was abnormal only to fast flicker photopic stimulation. This may indicate a relative vulnerability of a high frequency signal system under conditions of raised intracranial pressure. The abnormalities resolved rapidly once the intracranial pressure had been normalised. The cause of the VEP and particularly the ERG abnormalities remains unknown.

Adult↗

An electroretinal and visual evoked potential study in Friedreich's ataxia.

We made an electroretinographic (ERG) and visual evoked potential (VEP) study of 12 patients with Friedreich's ataxia whose diagnosis was established using the Quebec diagnostic criteria. ERGs and VEPs were elicited to the same stimulating conditions. Flash evoked luminance changes and pattern-specific evoked potentials to check and diamond stimuli were used. Statistical analysis of the data was made using independent sample t-tests. Significant VEP delays were present under all test conditions. The presence of significant interocular and interhemispheric delays as well as evidence of abnormal temporal dispersion of the VEP response suggest there to be both diffuse anterior visual system disease and retrochiasmal involvement in Friedreich's ataxia. The implicit times of the ERG b-waves were statistically within normal limits but the waveforms were of low amplitude and deformed and there were significant interocular implicit time differences. These ERG results suggest there are retinal conduction abnormalities in Friedreich's ataxia which possibly play a role in the genesis of the abnormal VEPs.

Adolescent↗

Abnormal pattern electroretinograms with macular cherry-red spots: evidence for selective ganglion cell damage.

A macular cherry red spot is a strikingly visible abnormality indicating storage of an abnormal metabolic product by the retinal ganglion cells. The flash and pattern electroretinograms (ERG) and visual evoked potentials (VEP) of a patient with the cherry-red spot-myoclonus syndrome, a sialidosis due to neuraminidase deficiency, were studied. The flash ERG was normal but the pattern ERG had an abnormal waveform with a significantly attenuated p-q wave component. Corresponding flash VEPs were normal, but pattern VEPs were delayed. This case documents human evidence that the pattern ERG is organised in the ganglion cells whereas the flash ERG, as is well known, is generated in the distal retina.

Animals↗

Effect of timolol maleate on intraocular pressure and pupil cycle time in normal eyes.

One drop of 0.5% timolol maleate instilled into the normal eyes of four subjects produced a marked reduction of intraocular pressure that was maximal at 3 hours but not significant after 12 hours. Instillation of one drop a day for 30 days produced a reliable, maintained reduction of intraocular pressure in the treated eye. The pupil cycle time in both eyes was measured at least twice daily for 1 week before timolol treatment to assess the reproducibility of the test and then twice daily for the 30 days of treatment with timolol. The drug had no significant effect on the pupil cycle time. Measuring the pupil cycle time should afford the ophthalmologist a useful method of assessing the progress of glaucomatous damage to the optic nerve while the patient is undergoing treatment with timolol, an assessment that was not possible when patients were treated with pilocarpine.

Administration, Topical↗

Improved contrast sensitivity with antireflective coated lenses in the presence of glare.

Contrast sensitivity was measured to quantify the glare-reducing effects of antireflective coatings of magnesium fluoride on spectacle lenses. Experiments were conducted on four subjects, who judged contrast thresholds while wearing corrective spectacles with noncoated and then coated lenses in both the absence and the presence of a source of glare (back-scattered reflection from the posterior surface of their lenses). Glare substantially reduced contrast sensitivity at all spatial frequencies; although the reduction was greater at higher spatial frequencies ther was no shift in peak contrast sensitivity. The coated lenses enhanced contrast sensitivity in the presence of glare between 1.5 and 5 times compared with the noncoated lenses. In the absence of glare, contrast sensitivity was greater with coated lenses than with noncoated lenses.

Adult↗

Increased visual field area with antireflective coated lenses in the presence of glare.

Visual fields were charted with the Goldmann perimeter for five subjects wearing corrective spectacles with noncoated lenses and then lenses with antireflective coatings of mmagnesium fluoride in both the absence and the presence of a source of glare (back-scattered reflection from the posterior surface of their lenses). There was a greater reduction in temporal isopters than nasal isopters in the presence of glare with both types of lenses, but the coated lenses were superior to the noncoated lenses in reducing the effect of glare on the visual field area.

Adult↗

Giant axonal neuropathy: visual and oculomotor deficits.

Giant axonal neuropathy, a generalised disorder or neurofilaments, presents as a chronic, progressive peripheral neuropathy in childhood. Evidence for central nervous system involvement is demonstrated in this study of four male patients with giant axonal neuropathy who had defective visual function and abnormal ocular motility. The visual system was studied by electroretinography, which showed normal retinal function, and by visual evoked potentials, which showed disease of both optic nerves and retrochiasmal visual pathways. The ocular motility disorder, studied by electrooculography, comprised defective pursuit, inability to maintain eccentric gaze with gaze paretic and rebound nystagmus, abnormal optokinetic responses and failure of suppression of the vestibulo-ocular reflex by fixation. These findings suggested involvement by giant axonal neuropathy of the cerebellar and brain stem pathways important in the control of ocular motility.

Axons↗