Understanding mammography findings.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S G Friedman.
Explore the source record for details and available documents.
BACKGROUND: The widespread use of diagnosis-related groups has led to a significant reduction in the length of hospital stay following many surgical procedures. In light of this, an examination of early discharge following carotid endarterectomy under general anesthesia was undertaken. PATIENTS AND METHODS: A prospective study of 72 patients was conducted, in which the workup was done on an outpatient basis, admission took place on the same day as surgery, and patients were discharged home on the day after carotid endarterectomy. RESULTS: There were no strokes or deaths following carotid endarterectomy, and only two transient ischemic attacks occurred. In 88% of the cases, discharge was possible on the first postoperative day. CONCLUSIONS: Early discharge following carotid endarterectomy under general anesthesia is safe and cost effective.
BACKGROUND: The purpose of this study was to compare the long-term results of Dacron and polytetrafluoroethylene (PTFE) aortic bifurcation grafts in a prospective randomized manner. METHODS: Sixty patients with aortoiliac occlusive disease were randomized to receive Dacron or PTFE bifurcation grafts. Preoperative risk factors, perioperative blood loss and fluid requirements, and postoperative complications were compared. A mean follow-up of 57 months was achieved. RESULTS: The immediate postoperative morbidity and mortality rates were similar in the two groups, and the long-term complications were low in number and comparable. The cumulative patency rate for Dacron graft limbs was 86% versus 95% for PTFE graft limbs. CONCLUSIONS: No significant differences were noted between the results achieved with Dacron and PTFE aortic bifurcation grafts.
BACKGROUND: This report describes six patients with atheroemboli to both lower extremities that originated from the abdominal aorta. All patients had severe bilateral rest pain and ulceration or gangrene. Each had severe coronary artery disease and other medical problems, which precluded direct aortic reconstruction. METHODS: Ligation of the external iliac arteries was performed to prevent continual passage of emboli into the lower extremities. Revascularization was effected by axillary-bifemoral bypass. RESULTS: Initial limb salvage was accomplished in twelve threatened extremities. One patient required a single toe amputation. One axillary graft failed after 3 months and was successfully replaced with a contralateral graft. These patients have been followed for up to 52 months without limb loss; the mean follow-up is almost 2 1/2 years. CONCLUSIONS: In patients with severe coronary artery disease and blue toe syndrome, the combination of external iliac ligation and axillary-bifemoral bypass is an effective and durable procedure to prevent worsening ischemia and to salvage threatened lower extremities.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Since 1984 three patients have been treated for a ruptured abdominal aortic aneurysm and acute biliary sepsis. The biliary tract disease included two cases of gangrene of the gallbladder, one with perforation. Two patients had cholangitis. All patients underwent repair of the ruptured aneurysm and cholecystectomy under the same anesthetic. Two individuals required common duct exploration: one at the time of the initial operation and the other 6 days later. Despite a high incidence of postoperative complications in these elderly men, all survived surgery and are alive and well after periods of 1 to 7 years. There have been no graft infections.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The preferential use of a synthetic arterial graft in the above-knee femoral-popliteal position is advocated by many surgeons for a variety of reasons. Our recent experience with three cases of substantial deterioration of runoff vessels within a brief period, which may have resulted from embolization from such a conduit, is presented along with other arguments against the routine use of a prosthesis in this position. The procedure with the best possible outcome, namely, one utilizing autogenous vein, should be performed at the outset in all patients except those with a limited life expectancy or those in whom a lengthy procedure would be hazardous.
We discuss the treatment of a fistula located between the aorta and inferior vena cava which was caused by trauma. Fewer than 30 such cases have been reported in the English literature. A juxtarenal pseudoaneurysm and aortocaval fistula resulting from a gunshot wound, unrecognized upon the initial presentation of the patient, is reported herein.
The advantages of tube versus bifurcation graft replacement of abdominal aortic aneurysms are well known, yet the risk of future development of iliac occlusive or aneurysmal disease still leads many to use bifurcation grafts routinely. Several studies have reported little risk of this development when patients are followed clinically. They suffer, however, from lack of an objective means of identifying iliac aneurysms. Among 83 patients undergoing abdominal aortic aneurysmectomy during a 53 month period, 36 who had received a tube graft were available for follow-up. After a mean of 54 months from the time of surgery, these patients were evaluated by abdominal and pelvic computed tomography to determine the incidence of subsequent iliac aneurysm formation. No patient had developed symptoms or signs of iliac occlusive disease during this interval. In addition, no residual aortic aneurysms or new iliac aneurysms were noted. In the absence of iliac occlusive or aneurysmal disease, straight graft replacement is the preferred therapy for abdominal aortic aneurysms. The risk of future development of these lesions is minimal.
Lower extremity bypass grafts to the tibial and crural arteries are commonly employed to treat patients with atherosclerotic limb-threatening ischemia. Although occasional series have mentioned bypasses to a plantar artery, few of these specifically examine the results of arterial reconstructions using these vessels. Six patients underwent femoral to lateral plantar artery (LPA) bypass within a 19-month period for gangrene of the forefoot. There was one early graft failure and in the five completely autogenous reconstructions, graft patency and limb salvage had been achieved during a follow-up ranging from three to 22 months. The LPA is an acceptable site for anastomosis of lower extremity bypass grafts and the early results presented herein support its more liberal use when proximal sites are unavailable.
In an attempt to analyze whether routine angiography is necessary prior to elective abdominal aortic aneurysmectomy (AAA), a prospective study was designed in which this examination was obtained only for specific indications. These included significant hypertension, renal dysfunction, symptoms of visceral ischemia, suprarenal extension of the aneurysm or a coexisting thoracic aneurysm, and diminished or absent femoral pulses. A consecutive series of 124 abdominal aortic aneurysms is reported, in which 110 procedures were performed electively. Preoperative angiograms were obtained in only ten patients (9.1%) and in nine of these an alteration in the usual operative strategy resulted. In the remaining 100 patients undergoing elective AAA without preoperative aortography, acceptable morbidity and mortality rates were obtained despite the intraoperative discovery of iliac aneurysms in 25 patients (23%) and accessory renal arteries in three patients (2.7%). In the absence of specific indications for angiography, the mainstay of the preoperative evaluation for abdominal aortic aneurysms should be computed tomography (CT). The preoperative workup can be done entirely on an outpatient basis.
Autogenous vein remains the conduit of choice for lower extremity revascularization. When a large or dilated vein is used in a reversed manner, there may occasionally be a large size discrepancy between it and a small tibial artery. A technique is presented that reduces this mismatch and facilitates anastomoses between large veins and small arteries.
Venous aneurysms are rare lesions. They may, however, be the source of pulmonary emboli and can result in death. We have recently treated several patients who had venous aneurysms of the upper extremity and jugular system. In these locations, venous aneurysms appear to have a safe natural history, although two patients required surgery after the development of symptoms. These cases are presented, with a review of venous aneurysms occurring at other sites and their cause.
Duplex imaging has been widely embraced as a safe and an accurate means of interrogating the extracranial carotid vessels. One reason for this is its appearance as a risk-free diagnostic tool. We report the cases of two patients in whom transient ischemic attacks developed during duplex imaging--attacks that began soon after application of the ultrasound transducer to the cervical region, were identical to prior attacks, and ceased within seconds of removal of the transducer from the neck. The underlying cause of this complication is discussed as is its proper management.