PubMed Health⌕ Search

Biomedical subjects

S G Perry

Publications and source records attributed to S G Perry.

10 recordsLinked to original sources

Ambulatory monitoring of pulmonary artery pressure. A preliminary clinical evaluation.

Traditional measurement and recording methods are inadequate for continuous monitoring of ambulatory pulmonary artery pressure. Therefore a new miniaturised solid state system has been developed and assessed. A manometer tipped catheter, inserted via a subclavian or cephalic vein, was used together with an isolated amplifier and peak detectors to determine systolic and diastolic pressures. Pressures were averaged over 30 seconds and stored in digital memory. After a 24 hour recording period data were rapidly transferred to a microcomputer for numerical or graphical display. Thirteen patients had continuous ambulatory monitoring performed for between 24 and 96 hours, in seven to evaluate symptoms of dyspnoea in subjects with valvular or coronary disease (group 1), and in six to achieve optimal oral treatment for left heart failure (group 2). The catheter was calibrated before insertion and was rechecked after removal. There was less than 1% zero level drift and similar gain stability. Systolic pressures ranged from 10 to 97 (mean 39.5) mmHg, and diastolic from 1 to 46 (mean 15.3) mmHg. Four patients in group 1 had symptoms of dyspnoea associated with normal pressures, while three had raised pressures. Four of the six patients monitored in group 2 had major alterations in their treatment based on data obtained during monitoring. There were no complications. This system, which allows safe, reliable, and prolonged recording of ambulatory pulmonary artery pressure, represents a considerable advance in the ability to assess the cause of dyspnoea and to manage left heart failure.

Adult↗

Distribution of two aminotransferases and D-amino acid oxidase within the nephron of young and adult rats.

In the adult rat kidney, alanine aminotransferase (EC 2.6.1.2), aspartate aminotransferase (EC 2.6.1.1) and D-amino acid oxidase (EC 1.4.3.3) were measured in glomeruli, 4 parts of the proximal tubule, 2 parts of the distal tubule and in patches from the thin limb area and the papilla. These enzymes were measured in more limited parts of the nephron during postnatal development. Adult aspartate aminotransferase activities (percentage of the highest) ranged from 100 in the distal straight segment to 25 in the late part of the proximal straight segment to 10 in the thin limb and papillary area. Alanine aminotransferase (lower by a factor of 100 in absolute terms) was distributed as the mirror image of aspartate aminotransferase within proximal and distal tubules. D-Amino acid oxidase was 850-fold higher in proximal straight segments than in medullary structures. During development alanine aminotransferase increased 6-fold and D-amino acid oxidase, 4.5-fold in proximal straight tubules but aspartate aminotransferase increased in distal straight tubles 8-fold.

Aging↗

Cytotoxic testing and leucocyte increase as an index to food sensitivity. II. Coffee and tobacco.

Cytotoxic testing has been used to identify and evaluate potential sensitizers among three adult age groups. Coffee and toabacco were used as single sensitizers to further illustrate the vivo WBC response technique, as an independent test for corroborating was advanced outlining a possible explanation of the cytotoxic test results. This theoretical approach might be used to study clinical problems where allergic etiologies are suspected.

Adult↗

A solid state recorder for ambulatory monitoring of pulmonary-artery pressure.

A compact, portable recording system has been developed to record pulmonary-artery pressure in ambulatory patients. A transducer mounted on the tip of a conventional cardiac catheter is inserted percutaneously and positioned in the main pulmonary artery. Analogue circuitry, including peak and trough detectors, pre-processes the pressure/voltage waveform to yield sampled values for the systolic and diastolic pressures. Systolic and diastolic values sampled every 30 s are digitized and stored in CMOS semiconductor memory. Data acquired over a prolonged period is transferred to a microcomputer for permanent storage and subsequent analysis. Five patients were each successfully monitored for at least 24 h. The zero-level drift was less than 1% and gain stability was also better than 1% over 48 h. This device allows practical, safe, reliable and prolonged pressure recording and has wide-ranging clinical potential.

Ambulatory Care↗