PubMed Health⌕ Search

Biomedical subjects

S G Richardson

Publications and source records attributed to S G Richardson.

At least 19 recordsLinked to original sources

Total body iron overload in welder's siderosis.

Welder's siderosis occurs as a consequence of the inhalation of iron dust. The iron overload of welder's siderosis is usually considered to be confined to the lungs. Here we present three proven cases of welder's siderosis associated with evidence of increased total systemic iron stores, as evidenced by increased serum ferritin levels. Multiple investigations including molecular genotyping for the common mutations found in genetic haemochromatosis failed to prove this was due to haemochromatosis, nor was there any evidence of any other recognised cause of systemic iron overload. Thus the systemic iron overload described seems likely to be due to either occupational exposure, an uncharacterised genetic haemochromatosis, or a combination of both.

Adult↗

Prediction of mechanical properties of human atherosclerotic tissue by high-frequency intravascular ultrasound imaging. An in vitro study.

Intravascular ultrasound may be useful for studying the natural history of atherosclerotic lesions of different morphologies and for guiding interventional strategies. This study was designed to test the hypothesis that tissue appearance by intravascular ultrasound is related to the biomechanical properties of atheroma components. Forty-three atheroma caps were obtained from the abdominal aortas of 22 patients at autopsy and studied with an ultrasensitive, servo-controlled spectrometer. By measuring the static strain caused by increasing levels of compressive stress from 30 to 90 mm Hg, the uniaxial unconfined compression stiffness (ratio of stress to strain) was determined. After mechanical testing, specimens were imaged with a 6F, 20-MHz intravascular ultrasound transducer, and images were interpreted by an investigator who was unaware of the mechanical measurements. Specimens were classified as nonfibrous (n = 14), fibrous (n = 18), or calcified (n = 11) based on intravascular ultrasound appearance. The static stiffnesses of the nonfibrous, fibrous, and calcified ultrasound classes were 41.2 +/- 18.8 kPa, 81.7 +/- 33.2 kPa, and 354.5 +/- 245.4 kPa, respectively (p = 0.0002 by analysis of variance). The times to reach static equilibrium (creep time) for the nonfibrous, fibrous, and calcified classes were 79.6 +/- 26.5 minutes, 50.2 +/- 20.0 minutes, and 19.4 +/- 8.1 minutes, respectively (p = 0.0007). Intravascular ultrasound appearance was most significantly related to biomechanical behavior when calcium deposits were noted; the differences in biomechanical behavior between nonfibrous and fibrous tissue appearances were less apparent.(ABSTRACT TRUNCATED AT 250 WORDS)

Aorta, Abdominal↗

Biplane transesophageal echocardiography utilizing transverse and sagittal imaging planes: technique, echo-anatomic correlations, and display approaches.

The recent development of biplane transesophageal probes equipped with both transverse plane and sagittal plane imaging transducers allows a more complete examination of cardiac and aortic anatomy than is possible with conventional single plane transesophageal instruments. While the imaging planes used in transverse plane transesophageal imaging have been standardized, several different approaches have been suggested for the orientation and display of the newer sagittal plane images. An accepted display convention for the transverse and sagittal plane images would ease interpretation of the multiple complex images obtained during the biplane transesophageal examination. In this article, the different transverse plane and sagittal plane echocardiographic images that may be acquired during the biplane transesophageal examination are described and correlated with cardiac anatomy. A method for image display orientation is suggested that is most consistent with that previously used for the single plane transesophageal examination.

Animals↗

Management of acute coronary occlusion during percutaneous transluminal coronary angioplasty: experience of complications in a hospital without on site facilities for cardiac surgery.

OBJECTIVE: To determine whether percutaneous transluminal coronary angioplasty may be safely performed in cardiology centres in the United Kingdom without immediate on site cardiac surgical cover for complications arising at angioplasty. DESIGN: Retrospective review of coronary angioplasties and complications in a hospital without on site cardiac surgical cover. SETTING: All angioplasties were performed in the catheterisation laboratory of the Belfast City Hospital. Revascularisation surgery for complicated coronary angioplasty was performed in the cardiac surgical unit of the Royal Victoria Hospital, 2.4 km away from the catheterisation laboratory. PATIENTS: 540 Coronary angioplasties were performed on 512 patients between late 1982 and November 1988. Indications included stable angina, unstable rest angina, and suitable coronary disease at coronary arteriography after myocardial infarction. MAIN OUTCOME MEASURES: In hospital mortality after complicated coronary angioplasty and delay to surgical revascularisation after acute coronary occlusion at angioplasty. RESULTS: Coronary angioplasty was successful in 444 cases (82%). Acute coronary occlusion occurred in 35 cases (6.5%). Twelve patients required urgent revascularisation surgery and were transferred safely to the surgical unit; none of these patients died. A mean delay of 268 minutes (range 180-390 minutes) occurred before revascularisation compared with 273 minutes (range 108-420 minutes) in the Royal Victoria Hospital, where on site surgical cover was available. The principal cause of delay was the wait for a cardiac operating theatre to become available and not the transfer time between hospitals. Five deaths occurred after coronary angioplasty, a mortality of 0.9%. Three deaths were related to acute coronary occlusion. The absence of immediate surgical help did not influence the outcome in any patient. CONCLUSION: With careful selection of patients coronary angioplasty may be safely performed in a hospital without on site cardiac surgical facilities, provided that these are available at a nearby centre.

Acute Disease↗

Problems and pitfalls in the performance and interpretation of color Doppler flow imaging: observations based on the influences of technical and physiological factors on the color Doppler examination of mitral regurgitation.

Color Doppler flow imaging has become an integral part of the echocardiographic examination. By providing real-time, two-dimensional spatial maps of normal and abnormal cardiac blood flows, this technique provides important information that may be used to guide patient management. The acquisition and display of color Doppler flow information may be influenced by technical factors, by the physiological condition of the patient, by abnormalities of cardiac morphology, and, on occasion, by artifact. In this article, the results of a study performed to evaluate the influence of technical factors on the color Doppler assessment of mitral regurgitation are reported. Mitral regurgitation jet area size changed significantly with variation in the control settings for color gain, color process, color map, color image resolution, and sector width. A review of those factors that influence the performance and interpretation of the color Doppler flow examination is provided and their significance discussed.

Echocardiography, Doppler↗

Lymphocytic lymphoma and acquired C1 esterase inhibitor deficiency.

We report a 59-year-old woman who had progressive symptoms of angioedema for 3 years, culminating in an attack of laryngeal stridor. C1 esterase inhibitor deficiency was confirmed and treatment with tranexamic acid produced considerable clinical benefit and improvement in complement levels. Two years later she developed clinical evidence of lymphocytic lymphoma. Splenectomy resulted in rapid correction of complement abnormalities. The patient received 6 months of chemotherapy after surgery and remained asymptomatic with normal complement levels 4 years later.

Angioedema↗

Pathological changes after intravenous streptokinase treatment in eight patients with acute myocardial infarction.

At necropsy five of eight patients (mean age 57 years) who died after intravenous streptokinase treatment for severe acute myocardial infarction (mean Peel index = 18) were found to have a patent infarct related coronary artery. Coronary artery stenoses were caused by fibrofatty atheromatous plaques; there were no residual thrombi in the lumen or acute intimal lesions. Three of these infarcts were of partial thickness (less than two thirds wall width) with sparing of the outer third of the myocardium and subendocardial zones. In the other three patients the infarct related coronary arteries remained histologically closed with residual lumen thrombi and underlying intimal lesions. Two infarcts were transmural. Six of the eight infarcts were noticeably haemorrhagic. Myocardial haemorrhage was confined to areas of necrotic myocardium and did not affect viable regions. These findings suggest that thrombus overlying a complex lesion may be more difficult to lyse than thrombus overlying a simple fibrofatty plaque. They also suggest that myocardial haemorrhage outside the infarct area, which might lead to cardiac rupture or delayed healing, does not usually occur.

Acute Disease↗

Relation of coronary arterial patency and left ventricular function to electrocardiographic changes after streptokinase treatment during acute myocardial infarction.

One hundred and eighty-eight patients with evolving acute myocardial infarction were treated with intravenous streptokinase. Serial 12-lead electrocardiograms were recorded for 3 hours after treatment and inspected for rapid repolarization changes of the ST segment and T wave. Abrupt electrocardiographic repolarization changes were observed in 106 patients (56%) and were strongly predictive for an open infarct-related coronary artery at a mean of 6 days after treatment (predictive value = 0.92, sensitivity = 0.67). Abrupt electrocardiographic changes were not observed in 82 patients (44%). This absence was not a good predictor of an occluded infarct-related coronary artery (predictive value = 0.4). There was no relation between the presence or absence of abrupt electrocardiographic changes and global or regional left ventricular function after streptokinase treatment. Abrupt repolarization changes after thrombolytic treatment indicate a high probability of an open infarct-related artery. When abrupt repolarization changes do not occur, the patency of the infarct-related coronary artery cannot be predicted with accuracy. Serial electrocardiographic recordings do not provide sufficient information about coronary patency to eliminate the need for coronary arteriography.

Aged↗

A serial study of platelet reactivity throughout the first six months after myocardial infarction: its modification by sulphinpyrazone.

Platelet reactivity was studied immediately after and throughout the first 6 months following myocardial infarction. Its modification by sulphinpyrazone was observed. Out of 65 consecutive patients admitted to the coronary care unit, ten did not meet the protocol criteria. Fifty five received either placebo or sulphinpyrazone in a double-blind trial for 6 months, treatment being started within 6 days of infarction. Forty four patients completed the study (19 on placebo and 25 on sulphinpyrazone). An additional ten patients commenced treatment within one day of infarction and were studied daily for one week. Platelet hyper-reactivity was demonstrable in all patients at presentation and persisted throughout the 6 months in the control group. This effect was reversed by sulphinpyrazone, the modification of reactivity being established by the third day of treatment.

Adult↗

Carbon balance and water relations of sorghum exposed to salt and water stress.

The daily (24 hour) changes in carbon balance, water loss, and leaf area of whole sorghum plants (Sorghum bicolor L. Moench, cv BTX616) were measured under controlled environment conditions typical of warm, humid, sunny days. Plants were either (a) irrigated frequently with nutrient solution (osmotic potential -0.08 kilojoules per kilogram = -0.8 bar), (b) not irrigated for 15 days, (c) irrigated frequently with moderately saline nutrient (80 millimoles NaCl + 20 millimoles CaCl(2).2H(2)O per kilogram water, osmotic potential -0.56 kilojoules per kilogram), or (d) preirrigated with saline nutrient and then not irrigated for 22 days.Under frequent irrigation, salt reduced leaf expansion and carbon gain, but water use efficiency was increased since the water loss rate was reduced more than the carbon gain. Water stress developed more slowly in the salinized plants and they were able to adjust osmotically by a greater amount. Leaf expansion and carbon gain continued down to lower leaf water potentials.Some additional metabolic cost associated with salt stress was detected, but under water stress this was balanced by the reduced cost of storing photosynthate rather than converting it to new biomass. Reirrigation produced a burst of respiration associated with renewed synthesis of biomass from stored photosynthate.It is concluded that although irrigation of sorghum with moderately saline water inhibits plant growth in comparison with irrigation with nonsaline water, it also inhibits water loss and allows a greater degree of osmotic adjustment, so that the plants are able to continue growing longer and reach lower leaf water potentials between irrigations.

Journal Article↗

Myelofibrosis, autoimmune haemolytic anaemia and Tn-polyagglutinability.

A patient with myelofibrosis was studied for about four years. During this period he developed autoimmune haemolytic anaemia, a rare complication of myelofibrosis. Furthermore, about two years after the investigation started, his red blood cells, previously normal, became Tn-polyagglutinable, a change known to be due to somatic mutation in haemopoietic stem cells.

Anemia, Hemolytic, Autoimmune↗

Carbon Balance of Sorghum Plants during Osmotic Adjustment to Water Stress.

The daily (24-hour) carbon balances of whole sorghum plants (Sorghum bicolor L. Moench cv BTX616) were continuously measured throughout 15 days of water stress, followed by rewatering and 4 more days of measurements. The plants were grown under controlled environment conditions typical of warm, humid, sunny days. During the first 12 days, osmotic potentials decreased in parallel with decreased water potentials to maintain pressure potentials near 0.5 kilojoules per kilogram (5 bars). Immediately before rewatering on day 15, the water potential was -3.0 kilojoules per kilogram. Osmotic adjustment at this point was 1.0 kilojoules per kilogram, as measured by the decrease in the water potential at zero turgor from its initial value of -1.4 kilojoules per kilogram.Gross input of carbon was less but the fraction retained was greater because a smaller fraction was lost through respiration in stressed plants than in unstressed plants. This was attributed to a lower rate of biomass synthesis, and conversely a higher rate of storage of photosynthate, due to inhibition of leaf expansion. The reduction in the cost associated with biomass synthesis more than balanced any metabolic cost of osmotic adjustment. The net daily gain of carbon was always positive in the stressed plants.There was a large burst of respiration on rewatering, due to renewed synthesis of biomass from stored photosynthate. Over the next 3 days, osmotic adjustment was lost and the daily carbon balance returned to that typical of nonstressed plants. Thus, osmotic adjustment allowed the stressed plants to accumulate biomass carbon throughout the cycle, with little additional metabolic cost. Carbon stored during stress was immediately available for biomass synthesis on rewatering.

Journal Article↗

Safety of reusing disposable plastic insulin syringes.

53 diabetic patients took part in a study to assess the safety of reusing plastic disposable syringes for insulin injection. Each patient used the same plastic syringe for 7 days. The syringe needles were changed when blunt. No patient developed signs of infection at the injection site. Bacteriological assessment of the used syringes and needles showed no contamination in any of the syringes, although one needle was contaminated. The effectiveness of bacteriostatic additives to insulin preparations was demonstrated. The presence of these additives renders safe the practice of a diabetic patient reusing a plastic disposable syringe over a 7-day period.

Adolescent↗