PubMed Health⌕ Search

Biomedical subjects

S Gianolini

Publications and source records attributed to S Gianolini.

4 recordsLinked to original sources

Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1.

The new DIN ('Deutsche Industrie-Norm') 6875-1, which is currently being finalised, deals with quality assurance (QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4-mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in-house, the use of commercially available tools facilitated the QA according to the DIN 6875-1 with which our results complied.

Quality Control↗

High precision radiosurgery and technical standards.

BACKGROUND: A high degree of precision and accuracy in radiosurgery is a fundamental requirement for therapeutic success. Small radiation fields and steep dose gradients are clinically applied thus necessitating a dedicated quality assurance program in order to guarantee dosimetric and geometric accuracy. MATERIAL AND METHODS: A detailed analysis of the course of treatment independent of the irradiation technique used results in the so-called chain of uncertainties in radiosurgery (immobilisation, imaging, treatment planning system, definition of regions of interest, mechanical accuracy, dose planning, dose verification). Each link in this chain is analysed for accuracy and the established quality assurance procedures are discussed. A "System Test" was used to check the whole chain of uncertainties simultaneously. RESULTS: The tests described are compatible with published reports on quality assurance in radiosurgery. In terms of accuracy the weakest link in the chain of uncertainties is stereotactic MR imaging. Geometric overall accuracy measured in the "System Test" is less than 0.7 mm. CONCLUSION: The established quality assurance routines have clinically been validated. MR imaging dominates geometric overall accuracy in radiosurgery, which can be limited to less than 1 mm by an adequate quality assurance protocol.

Adenoma↗

Gamma knife radiosurgery as a primary treatment for prolactinomas.

OBJECT: The purpose of this study was to estimate the efficacy of gamma knife radiosurgery (GKS) in controlling tumor growth and endocrinopathy associated with prolactinomas. METHODS: Between 1993 and 1997, 164 of 469 patients with pituitary adenomas treated by GKS harbored prolactinomas. The dose to the tumor margin ranged from 9 to 35 Gy (mean 31.2 Gy), and the visual pathways were exposed to a dose of less than 10 Gy. The mean tumor diameter was 13.4 mm. The mean follow-up time for 128 cases was 33.2 months (range 6-72 months). Tumor control was observed in all but two patients who underwent surgery 18 and 36 months, respectively, after GKS. Clinical cure was achieved in 67 cases. Clinical improvement was noted with a decrease in the hyperprolactinemia after GKS. Nonetheless, in 31 (29%) of 108 patients who were followed for more than 2 years no improvement in serum prolactin levels was demonstrated, although this could be normalized by bromocriptine administration after treatment. Nine infertile women became pregnant 2 to 13 months after GKS and all gave birth to normal children. There was no visual deterioration related to GKS. Five women experienced premature menopause. In these patients there was subtotal disappearance of the tumor and an empty sella developed. CONCLUSIONS: Gamma knife radiosurgery as a primary treatment for prolactinomas can be safe and effective both for controlling tumor growth and for normalization of prolactin hypersecretion. A higher margin dose (> or = 30 Gy) seemed to be associated with a better clinical outcome. Gamma knife radiosurgery may make prolactinomas more sensitive to the bromocriptine.

Humans↗

Resolution dependency of microstructural properties of cancellous bone based on three-dimensional mu-tomography.

Micro-computed tomography (microCT) is an emerging technique for the non-destructive assessment and analysis of the three-dimensional cancellous bone architecture. However, the procedures the procedures and applications used to quantify bone structures are not yet standardized. The aim of this study was to provide more insight in the resolution-dependency of microstructural properties of three-dimensional trabecular bone. Ten iliac crest bone biopsies were measured using a newly devised microCT system providing a nominal isotropic resolution of 14 microns. To study the resolution dependency the measured data were reconstructed on reduced image arrays with reduction factors ranging from 2 to 20. To assess the structural properties, morphometric parameters were computed based on a truly three-dimensional approach. The results showed a strong resolution dependency of the structural properties and that, if very precise results are needed, only the highest resolution will predict the correct values. Nevertheless, since the properties either decrease or increase monotonously up to a nominal resolution of about 175 microns, the values appear to be restorable using a suitable calibration procedure.

Bone Matrix↗