PubMed Health⌕ Search

Biomedical subjects

S Girotti

Publications and source records attributed to S Girotti.

30 records · Page 2Linked to original sources

Methodological problems of direct bioluminescent ATP assay in platelets and erythrocytes.

Direct bioluminescent ATP determination in platelets and erythrocytes involves the study of different parameters which are discussed here. Some parameters are linked to the bioluminescent reaction and to the analyte (ATP); others have regard to the biological matrix. The composition of bioluminescent reagents and the preparation and conservation of the ATP standard, also in the presence of excipients, are among the first given. Matrix problems involve cell characteristics related to age and form, lysis resistance and the possible formation of aggregates (platelets) that may inhibit the complete release of ATP. For these reasons we used the most efficient ATP release agent with the lowest inhibitory effect on luciferase. The data obtained correlate well with a bioluminescent method requiring extraction with ethanol/EDTA, and therefore more time, for ATP determination in platelets and erythrocytes.

Adenosine Diphosphate↗

Development of a sensitive, direct luminescent enzyme immunoassay for plasma estradiol-17 beta.

A rapid, sensitive, precise, chemiluminescent enzyme immunoassay for estradiol-17 beta has been developed and validated. Antibodies were produced in rabbits using estradiol-17 beta-6-(O-carboxymethyl)oxime coupled to bovine serum albumin, purified and immobilized on polystyrene beads (6.4 mm diameter). The same derivative was used to prepare the enzymatic tracer by coupling with horseradish peroxidase. The assay, direct on the serum sample, featured a 4-h binding step at 4 degrees C followed by the chemiluminescent detection using luminol/H2O2. The detection limit was 0.15 pg/tube and the assay was carried out on 20-100 microliter of sample, allowing measurement of estradiol-17 beta in plasma concentrations from 1.5 to 500 pg/ml. The method fulfills all the standard requisites of precision and accuracy and the results agree well with a radioimmunoassay procedure on extracted serum.

Cross Reactions↗

Continuous-flow determination of primary bile acids, by bioluminescence, with use of nylon-immobilized bacterial enzymes.

We describe a continuous-flow bioluminescence method for measuring primary bile acid in serum, with nylon as the solid support. 7 alpha-Hydroxysteroid dehydrogenase (EC 1.1.1. 159), a bacterial luciferase (EC 1.14.14.3), and NAD+:FMN oxido-reductase (EC 1.6.8.1) are covalently co-immobilized on a nylon coil (1 m X 1.0 mm i.d.). The assay is highly specific for 7 alpha-hydroxy bile acids. Other bile acids and steroids do not interfere. The continuous-flow light-emitting system, in which the reactor (nylon coil) is placed in front of a photomultiplier tube inside a luminometer, is versatile and simple. The flow is air-segmented, and serum samples (5-50 microL) can be injected directly. Concentration and response are linearly related from 10 to 2500 pmol per assay tube. The precision of the method is satisfactory (CV 5-10%), both inter- and intra-assay. We validated the technique by comparing results with those by RIA, enzyme immunoassay, and "high-performance" liquid chromatography. More than 20 samples an hour can be analyzed, with no carryover. The nylon-immobilized enzymes are stable for more than two months, and greater than 500 samples can be analyzed with use of a few milligrams of enzymes. Normal values for bile acid content of serum ranged from 1 to 2.5 mumol/L, in agreement with those obtained by other methods.

Autoanalysis↗

Continuous-flow bioluminescent determination of ATP in platelets using firefly luciferase immobilized on epoxy methacrylate.

Firefly luciferase was immobilized on epoxy methacrylate beads and used for a continuous-flow assay of ATP extracted from platelets. The immobilized luciferase had a half-life of 3 days at 25 degrees C; there was a 25% recovery of luciferase activity upon immobilization, and ca 50 reactors were made from 1 mg of commercial enzyme. The sensitivity of the assay was 0.3 pmol of ATP, and the response was linear between 1 and 500 pmol of ATP. The ATP content of platelets obtained with the present method correlated well with those obtained using soluble luciferase.

Adenosine Triphosphate↗

Enhanced chemiluminescent sandwich enzyme immunoassay for hen egg lysozyme.

A sensitive chemiluminescent sandwich-type enzyme immunoassay for hen egg lysozyme was developed. The assay was performed on polystyrene microtitre plates using immobilized specific polyclonal rabbit antibody against lysozyme, a peroxidase conjugate and the H2O2/luminol-enhanced chemiluminescence detection reagent. The chemiluminescent signal was detected using either a microplate luminometer, or photographic film in a camera luminometer. The detection limit for lysozyme was 0.3 ng/mL, and this was three times lower than that obtained using a colorimetric method with H2O2 and o-phenylendiamine as substrates. Recovery of the assay was 97-112% and the relative standard deviation ranged from 3.6% to 10.3%. The immunoassay overcame interference from the food sample matrix when lysozyme, used as a bacteriostatic agent, was measured.

Animals↗