PubMed Health⌕ Search

Biomedical subjects

S Golar

Publications and source records attributed to S Golar.

4 recordsLinked to original sources

Electrophysiological and biochemical changes in rabbit hearts stored at 4 degrees C for 6 or 24 h.

This study examines the electrophysiological and metabolic changes that occur in rabbit hearts during hypothermic storage in vitro. Hearts were microperfused at 4 degrees C for 6 or 24 h with either normal Krebs-Henseleit buffer (KHB) or KHB containing 2,3-butanedione monoxime (BDM). After hypothermic storage, hearts were rewarmed to 37 degrees C with KHB. Cardiac function was then assessed in Langendorff perfusion mode. Electrophysiological changes were also assessed from the ventricular paced-evoked responses. After storage, mitochondria were isolated from the hearts and their respiratory control ratio, rate of ATP synthesis and outer membrane intactness were assessed. Compared with values from fresh non-stored hearts, hearts stored hypothermically for 24 h showed significant decreases in both left ventricular developed pressure and coronary flow when reperfused in Langendorff mode. On the other hand, the decrease in left ventricular developed pressure in hearts that were stored for only 6 h (with or without BDM) was not significant. Compared with values obtained from fresh non-stored hearts, hypothermic storage significantly decreased the R-wave amplitude, and both the R-E and ST-E intervals of paced-evoked responses. This was true for hearts microperfused for 6 h (with or without BDM) and for hearts microperfused with buffer containing BDM for 24 h. The ST-R intervals in hearts microperfused hypothermically for 6 h were prolonged, but this change was not statistically significant compared with those obtained from unstored hearts. In hearts microperfused with KHB containing BDM for 24 h, the ST-R interval was significantly prolonged. Hypothermic microperfusion for 24 h significantly decreased both the mitochondrial coupling ratio and the rate of ATP synthesis. In hearts microperfused with BDM for 6 h, mitochondrial coupling ratios and the rate of ATP synthesis were not significantly different from those in fresh hearts. In conclusion, the present study has shown that long-term hypothermic storage significantly impaired both paced-evoked responses and mitochondrial function. Inclusion of BDM in the perfusion buffer during storage significantly ameliorated some of these changes.

Adenosine Triphosphate↗

Prolonged and multipatient use of prefilled disposable oxygen humidifier bottles: safety and cost.

OBJECTIVES: Multipatient use and prolonged use of prefilled disposable oxygen humidifier bottles (Aquapak 301, Respiratory Care, Inc., Arlington Heights, IL) were evaluated by performing microbiologic monitoring and a cost analysis on bottles used for varying numbers of patients and lengths of time. METHODS: Humidifiers were hung for a maximum of one month. Monitoring was conducted in 6 different nursing areas. Quantitative cultures were done for aerobes and Legionella. Reusable humidifier bottles also were monitored. RESULTS: Cultures were obtained from 1,311 disposable and 60 reusable humidifiers. No significant bacterial contamination was detected in the prefilled disposable oxygen humidifier units. Ten percent of the reusable bottles were contaminated by organisms associated with skin flora. CONCLUSIONS: Multipatient use and increased duration of use of disposable humidifiers result in cost savings without increasing patient risk. Restricted multipatient use of prefilled disposable oxygen humidifier bottles for a period of one month is a safe and cost-efficient practice.

Alberta↗