Criterion validity of the cervical range of motion (CROM) goniometer for cervical flexion and extension.

STUDY DESIGN: This study used a validity protocol. OBJECTIVE: To estimate the criterion validity of the Cervical Range of Motion goniometer using a healthy population. SUMMARY OF BACKGROUND DATA: The results of the 1994 study by Mayo et al show that there are no validated tools currently available for clinically measuring the cervical range of motion. Numerous decisions regarding patient status and treatment are based wholly or in part on joint motion measurements. Because of current budgetary restrictions, clinicians are being asked to justify their interventions objectively, and to do so, they will need validated tools. METHODS: The population consisted of 31 healthy participants ranging in age from 18 to 45 years. None had experienced cervical problems in the previous 3 months or were pregnant. Data collection took place at the radiology department. After participants were positioned on a stool, the cervical range of motion goniometer frame was set on their head by the physiotherapist. With the participant in this neutral position, the physiotherapist took the first Cervical Range of Motion measurement. The radiograph technologist obtained the radiograph immediately afterward. This procedure was repeated with the participant in fully flexed and fully extended positions. RESULTS: A Pearson's r correlation test was used to evaluate the criterion validity of the Cervical Range of Motion goniometer versus the radiographic method. The two measurements proved to be highly correlated (flexion: r = 0.97, P < 0.001; extension: r = 0.98, P < 0.001). CONCLUSIONS: For this population of healthy participants, the Cervical Range of Motion goniometer was found to be valid for measurements of cervical flexion and extension. Further research is needed on the validity of this instrument for other cervical spine movements.

Adolescent↗

The Molteno M-Sphere.

PURPOSE: To analyze a mammalian hydroxyapatite (HA) implant known as the Molteno M-Sphere, recently approved by the Food and Drug Administration of the United States. METHODS: The authors examined the implant macroscopically, with chemical analysis (x-ray powder diffraction, x-ray fluorescence spectrophotometry), and microscopically with scanning electron microscopy. Animal implantation of six Molteno M-Spheres was carried out in six adult male New Zealand albino rabbits. Implant vascularization was evaluated by means of magnetic resonance imaging and histopathologic sectioning. RESULTS: The M-Sphere was found to have multiple interconnected pores throughout with an average pore size of 300 microm to 600 microm. This implant was very light-weight (0.31 g) and fragile. It was made up of pure HA. Magnetic resonance imaging studies showed implant enhancement to its center by 4 weeks after implantation. Histopathologically, fibrovascularization occurred uniformly throughout the 4, 8, and 12-week rabbit implants. CONCLUSIONS: The M-Sphere is an alternative type of HA implant that recently has been reintroduced into the United States for use after enucleation, evisceration, or as a secondary implant. It has multiple interconnected pores allowing central fibrovascularization as early as 4 weeks in a rabbit model. Its light weight and fine trabecular framework, however, are associated with increased implant fragility when compared with other available HA implants (BioEye and FCI3 synthetic HA). The implant requires careful handling because routine handling may damage the implant. The implant is currently approved by the United States Food and Drug Administration.

Animals↗

Brazilian hydroxyapatite implant.

PURPOSE: To evaluate a synthetic hydroxyapatite (HA) (manufactured in Brazil) in a rabbit model. METHODS: Nine New Zealand white rabbits underwent enucleation of one eye followed by implantation of either a 12-mm Brazilian synthetic HA implant or a 12-mm BioEye, wrapped in polyglactin 910 mesh. Magnetic resonance imaging was performed to assess fibrovascular ingrowth 4, 8, and 12 weeks after implantation. Three animals were killed at each of the times for histopathologic examination. The Brazilian implant was also examined chemically and by scanning electron microscopy. RESULTS: The Brazilian HA was found to be heavier than either the BioEye or synthetic FCI3 HA implants. It did not have a visible, regularly arranged interconnected porous architecture. Rather, it had randomly appearing channels apparent on its external and internal surface in addition to large cystic areas within the body of the implant. Scanning electron microscopy revealed the implant to have a microporous architecture in addition to the large channels and cystic cavities. Histopathologically, central vascularization occurred by 4 weeks and was also present at 8 and 12 weeks. In three Brazilian implants an unrecognizable, nonbirefringent material was identified. The cause of it was unclear. Chemical analysis confirmed the implant to consist of pure HA. CONCLUSION: The Brazilian implant is pure HA that appears solid but has randomly arranged channels as well as a microporous architecture that allows vascularization to its center. It is heavier than other available HA implants and has the presence of an unidentified foreign material within it. Although this implant is less expensive and does not require a costly manufacturing process, the structural characteristics of the material do not offer any theoretical or clinical advantages. The implant is only available in Brazil at this time.

Animals↗

Mild head injury: a misnomer.

Despite controversy surrounding the concept of mild head injury (MHI), it is becoming evident that even a head trauma termed 'mild' may result in significant behavioural sequelae. The present study was an attempt at documenting structural cerebral damage, by way of computerized tomography, in a group of patients having suffered a MHI as defined by the Glasgow Coma Scale (GCS) score. A 1-year retrospective chart review identified 80 MHI patients who presented to the Emergency department of a lead hospital for trauma. Sixty-six per cent of these MHI patients were scanned. Evidence of intracranial abnormalities was obtained in 31% of the overall sample. Patients with a lower GCS score had a higher percentage of abnormal scans than those with a GCS score of either 14 or 15. The present findings suggest that a MHI can be associated with significant morbidity, and that a MHI group does not constitute a homogeneous pool of patients.

Adult↗

Lumbosacral plexopathy from iliopsoas haematoma after combined general-epidural anaesthesia for abdominal aneurysmectomy.

PURPOSE: To report a case of iliopsoas haematoma after resection of an abdominal aortic aneurysm which resulted in a lumbosacral plexopathy. CLINICAL FEATURES: An 81-yr-old man presented with an abdominal aortic aneurysm for aneurysmectomy and tube grafting. An epidural catheter was placed at the L1-2 spinal level and combined epidural-general anaesthesia was provided for surgery. The surgery was complex and a suprarenal clamp was necessary to obtain proximal control. A continuous infusion of demerol through the epidural catheter was prescribed for postoperative analgesia. On the first postoperative day, examination revealed a paretic, pulseless right leg and he was returned to the operating room for femoral-femoral bypass. By the following day, the motor and sensory impairment had progressed to complete paralysis with loss of all deep tendon reflexes and absent sensation below L1, despite palpable pulses in the leg. A CT of the abdomen demonstrated a right iliopsoas haematoma. There was no evidence of either disc herniation or an epidural haematoma. A diagnosis of lumbosacral plexopathy secondary to a iliopsoas haematoma was made. CONCLUSION: Iliopsoas haematoma is a rare cause of postoperative neurological deficit following aortic vascular surgery. The haematoma results in compression of the lumbosacral neural elements and typically presents as a femoral neuropathy. The diagnosis is clinical and can be readily validated with computed tomography.

Aged↗

The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants.

Hydroxyapatite (HA) implants currently are most commonly wrapped in donor sclera before implantation to facilitate placement within the orbit and allow attachment of the extraocular muscles. Although the risk of acquiring a transmittable disease through donor sclera is extremely low, some individuals remain concerned about receiving nonautologous material. As an alternative to sclera, autologous temporalis fascia, or autologous fascia lata, we have been wrapping HA in "Vicryl mesh" before insertion into the orbit. The Vicryl mesh-wrapped implant goes into the socket readily, allows one to easily attach the extraocular muscles, and has no risk of transmittable disease. In addition, the Vicryl mesh is readily available at most hospitals and is dissolvable.

Durapatite↗

Visualization of C7-T1 on portable lateral cervical spine radiographs using a lead-lined acrylic filter.

OBJECTIVE: To determine whether lead-lined acrylic cervical filters can improve the quality of portable lateral cervical spine (c-spine) radiographs for trauma patients. METHODS: Twenty trauma patients who required portable c-spine x-rays had these taken with a lead filter attached to the collimator of the portable x-ray machine to improve penetration and visualization of lower cervical structures without overpenetrating upper cervical structures. The radiographs of these patients were compared with the first portable c-spine radiographs without filters for 20 controls matched for gender and injury severity. The comparison of radiographs was done by an experienced emergency physician and a neuroradiologist blinded to whether the filter was used. RESULTS: The two groups were similar for demographic and clinical characteristics. There was a significant improvement in the ability to visualize the C7-T1 level for the filter group compared with the control group (65% vs 30%, p < 0.05). Agreement between the physicians was excellent (kappa = 0.79, 95% CI = 0.60-0.99). CONCLUSIONS: Lead-lined acrylic filters improve the ability to visualize the lower c-spine in trauma patients.

Adult↗

Diffuse idiopathic skeletal hyperostosis: an unusual cause of difficult intubation.

A case is reported in which anterior osteophytes on the cervical vertebra, in combination with a subglottic stenosis, resulted in distortion of the airway and led to unexpected difficulties during intubation. The osteophytes, associated with the syndrome of diffuse idiopathic skeletal hyperostosis (DISH) were centred at the midcervical level and resulted in anterior displacement of the larynx with an acute angulation of the trachea just below the larynx. This acute angulation, immediately above an unrecognized subglottic stenosis, rendered it impossible to pass all but the smallest endotracheal tube. Diffuse idiopathic skeletal hyperostosis is an ossifying diathesis leading to bone formation in spinal and extraspinal sites, paravertebral osteophyte formation and ligamentous calcification and ossification. Ossification of the anterior longitudinal ligament is common, may be discontinuous, and is often more marked in the thoracolumbar spine than elsewhere. However, isolated and predominant cervical spinal involvement may occur. Diffuse idiopathic skeletal hyperostosis occurs primarily in the elderly population and is often associated with the syndromes of osteoarthritis and ossification of the posterior longitudinal ligament (OPLL). Difficult intubation resulting from anatomical abnormalities of the cervical spine is rare. Although radiological evaluation may be useful in assessing the airway in patients deemed to be at risk for difficult intubation, it cannot be recommended for screening patient populations on a routine basis because of the cost and anticipated extremely low yield. Careful clinical evaluation of the airway before operation and having an approach to the unexpected difficult intubation are emphasized.

Aged↗

Intracranial hemorrhage after stenting and angioplasty of extracranial carotid stenosis.

BACKGROUND AND PURPOSE: The transluminal angioplasty and stenting procedure has been recently advocated as a potential alternative to surgical endarterectomy for the treatment of severe extracranial carotid stenosis. This study assesses the incidence and significance of intracranial hemorrhage occurring after this procedure. METHODS: We retrospectively reviewed 104 carotid arteries (96 internal, two external, and six common) in 90 patients (63 male; mean age, 69.4 years; range, 48-88 years) who underwent primary stenting and angioplasty by use of Wallstents (103/104) at three centers between January 1996 and January 1999. Seventy-five (83%) patients were referred by neurosurgery departments. Seventy-one (68%) arteries were symptomatic; the mean stenosis percentage was 85% (range, 40-99%). RESULTS: Four intraparenchymal hemorrhages occurred, representing 4.4% of patients and 3.8% of vessels, after angioplasty and stent placement. The mean preoperative stenosis percentage was 95% (range, 90-99%). One hemorrhage occurred immediately after stent placement, whereas the three other hemorrhages occurred in a delayed fashion (mean, 2.8 days). The mean hematoma size was 4.8 cm (range, 2-8 cm). Three patients had associated subarachnoid or intraventricular bleeding; the fourth had associated subdural hemorrhage. Three hemorrhages were fatal; the fourth experienced two seizures only. No acute neurologic symptoms were present prior to hemorrhages, and there was no postprocedural hypertension in these patients. All had been receiving antiplatelet agents as well as intraprocedural IV heparin. CONCLUSION: Intracranial hemorrhage can occur after carotid angioplasty and stenting. We speculate that this represents cerebral hyperperfusion injury. The 3.8% incidence of cerebral hemorrhage observed is approximately sixfold greater than that reported post endarterectomy (0.6%) (95% CI, 0.2-8.7%). This is not statistically significant in this small study group. This trend may reflect patient selection, different anticoagulation protocols, and/or study population size. Additional data are needed to determine the safety and efficiency of carotid stenting as a treatment for carotid stenosis.