PubMed Health⌕ Search

Biomedical subjects

S H Yeung

Publications and source records attributed to S H Yeung.

4 recordsLinked to original sources

Comparison between percutaneous transverse fixation and intramedullary K-wires in treating closed fractures of the metacarpal neck of the little finger.

We performed a non-randomized controlled clinical trial of 59 clinical cases to compare percutaneous transverse K-wire fixation and intramedullary K-wires in treating closed fractures of the metacarpal neck of the little finger. Twenty-nine patients were treated by percutaneous transverse K-wire fixation and 30 patients were treated with intramedullary K-wires. They were reviewed at a mean follow-up of 24 months for radiological and functional outcome in terms of union rate, union time, complication rate, pain, movement and grip strength. Radiographs did not show any significant differences in the union rate and union time. There was no statistical difference in complication rate, pain scores, total active motion and grip strength between the two groups. The authors suggest that both methods are comparable, good and safe methods of treating closed, displaced fractures of the metacarpal neck of the little finger, without significant complications.

Adolescent↗

Use of an electronic barcode system for patient identification during blood transfusion: 3-year experience in a regional hospital.

OBJECTIVE: To evaluate the use of an electronic barcode system for patient identification during blood transfusion. DESIGN: Retrospective study. SETTING: Regional hospital, Hong Kong. PATIENTS: For all patients requiring blood transfusion between May 1999 and April 2002, with the exception of patients in the psychiatric wards and the accident and emergency department, a portable, hand-held scan-and-print electronic device was used to verify and document patients' identity at two critical points of transfusion: blood sampling for the compatibility test and blood administration. MAIN OUTCOME MEASURES: Scope of use of the electronic device, cost, effectiveness, staff compliance, problems and solution for improvement. RESULTS: In the first 3 years of hospital-wide use of the new device, no incidents of blood transfusion to wrong patients, or wrong labelling of blood samples, occurred with 41,00 blood sampling procedures and administration of 27 000 units of blood. Blood sampling took 6 minutes to complete with the use of the electronic device-similar to that taken by the conventional second-checker system. Among hospital staff, the compliance rate of using the new device approached 90%. Battery problems occurred in 12% of episodes of use of the device. CONCLUSIONS: The electronic barcode system was effective in reducing human error related to bedside transfusion procedures. The future goal is to tailor-make a more efficient device with additional functions.

Attitude of Health Personnel↗

Clear cell chondrosarcoma: case report and ultrastructural study.

A case of clear cell chondrosarcoma in a Chinese patient is described. The clear cells showed strongly positive S-100 protein immunoreactivity. Ultrastructurally 2 types of chondroid cells were demonstrated. One type appeared more primitive with abundant electron-lucent cytoplasm and sparse organelles. The other type of cell was more differentiated with presence of microvilli and numerous dilated cisternae of endoplasmic reticulum. Previous ultrastructural studies on these lesions were reviewed and compared with the present findings.

Adult↗