PubMed Health⌕ Search

Biomedical subjects

S Hildebrand

Publications and source records attributed to S Hildebrand.

11 recordsLinked to original sources

Radiologist's clinical information review workstation interfaced with digital dictation system.

Efficient access to information systems integrated into the radiologist's interpretation workflow will result in a more informed radiologist, with an enhanced capability to render an accurate interpretation. We describe our implementation of radStation, a radiologist's clinical information review workstation that combines a digital dictation station with a clinical information display. radStation uses client software distributed to the radiologist's workstation and central server software, both running Windows NT (Microsoft, Redmond, WA). The client system has integrated digital dictation software. The bar-code microphone (Boomerang, Dictaphone Corp, Stratford, CT) also serves as a computer input device forwarding the procedure's accession number to the server software. This initiates multiple queries to available legacy databases, including the radiology information system (RIS), laboratory information system, clinic notes, hospital discharge, and operative report system. The three-tier architecture then returns the clinical results to the radStation client for display. At the conclusion of the dictation, the digital voice file is transferred to the dictation server and the client notifies the RIS to update the examination status. The system is efficient in its information retrieval, with queries displayed in about 1 second. The radStation client requires less than 5 minutes of radiologist training in its operation, given that its control interface integrates with the well-learned dictation process. The telephone-based dictation system, which this new system replaced, remains available as a back-up system in the event of an unexpected digital dictation system failure. This system is well accepted and valued by the radiologists. The system interface is quickly mastered. The system does not interrupt dictation workflow with the display of all information initiated with examination bar-coding. This system's features could become an accepted model as a standard tool for radiologists.

Data Collection↗

Integration of radiologist peer review into clinical review workstation.

Professional peer review of random prior radiologist's interpretations is mandated by the Joint Commission on Accreditation of Healthcare Organizations (JCAHO). The JCAHO expects documentation of 5% rate of random peer-review cases. Countless hours are spent in departments fulfilling these requirements. The integration of the peer-review process into the radiologist's interpretation workflow was expected to increase the percentage of documented peer review, yet decrease the time and effort for this documentation. radStation clinical review workstations are deployed at every reading station. When a requisition is bar-coded, radStation retrieves the patient's clinical information and automatically displays the prior comparison report. If the radiologist agrees with the prior report, a single click on a "quality assurance' agree box documents the agreement. In the case of a discordance, an additional dialog box automatically appears and the radiologist enters the reason for disagreement and then submits the case as a discrepancy. The system holds the discordance for 3 to 5 working days, then notifies the original radiologist via E-mail that a prior interpretation has been submitted for peer review, lists the submitted discrepancy reason, and provides a link to display the discordant report. The peer-review database is separate from the existing radiology information system (RIS). At the end of every month, summary reports of all peer-review activity are generated automatically. Initial benchmarks of our deployed system anticipate documentation of long-term random peer-review rate at greater than 50% of interpreted cases. The system enhances the peer-review process by integrating it with the normal interpretation workflow. The time to complete peer review using radStation is less than 1 second per normal case and less than 60 seconds for a discordant case. The E-mail notification system is fully automated, eliminating the need for secretarial involvement in the data collection. This system has completely replaced a manual paper-based system. The integration of peer review directly into the radiologist's interpretation workstation greatly enhances the capability to easily exceed JCAHO standards. The overall increase in peer-review documentation should continue to improve the ability to document a consistent high quality of patient care.

Computer Communication Networks↗

RadStation: client-based digital dictation system and integrated clinical information display with an embedded Web-browser.

RadStation is a digital dictation system having an integrated display of clinical information. The three-tiered system architecture provides robust performance, with most information displayed within one second after a request. The multifunctional client tier is a unique client/browser hybrid. A Web browser display window functions as the client application's data display window for clinical information, radiology reports, and laboratory and pathology results. RadStation provides a robust platform for digital dictation functionality. The system's internal status checks ensure operational integrity in a clinical environment. Also, the programmable dictation microphone and bar-code reader supplant the mouse as the system's primary input device. By merging information queries into existing work flow, radiologist's interpretation efficiency is maintained with instant access to essential clinical information. Finally, RadStation requires minimal training and has been enthusiastically accepted by our radiologists in an active clinical practice.

Computer Peripherals↗

Surgical treatment for colic in the foal (67 cases): 1980-1992.

Sixty-seven foals age < 150 days underwent a ventral celiotomy for colic. Of the 67 foals, 51 foals (82%) recovered from anaesthesia and 42 (63%) were subsequently released from the hospital. Three (6%) of the 51 foals were subjected to a repeat celiotomy. Long term follow-up was available on 36 foals. Twenty-nine (57%) of the 51 foals recovered from anaesthesia, were alive at least 2 years following surgery. Adhesions were identified in 8 (17%) of the foals which recovered from general anaesthesia but were subsequently subjected to euthanasia due to recurrent colic. Strangulating lesions were associated with a lower survival rate. Nineteen per cent of foals with strangulating intestinal lesions survived > 2 years following surgery, compared to 69% of foals with nonstrangulating lesions. The age of foals on admission had a significant effect on survival. Only 10% of foals less than 14 days of age survived, compared to 45.8% of foals between age 15 and 150 days.

Aging↗

Neuromuscular blocking agents in equine anesthesia.

In summary, neuromuscular blocking agents can be used safely and to advantage in equine anesthesia. Muscle-relaxant use in equine anesthesia has been helped by the development of new relaxants such as atracurium, which has a reliable and reproducible duration of action. There are certain cases that benefit particularly by the use of relaxants but their use is not limited to these cases. These cases involve horses that experience persistent movement and hypotension during anesthesia, are undergoing ophthalmic or abdominal surgery or fracture repair, or are severely ill. Horses receiving muscle relaxants during anesthesia require mechanical ventilation, and neuromuscular blockade should be monitored with a peripheral-nerve stimulator.

Anesthesia↗

Circulating immune complexes in ankylosing spondylitis.

Circulating immune complexes were determined in the sera of patients with ankylosing spondylitis using a polyethylene glycol precipitation laser nephelometer technique. Positive results were obtained in 52% of sera from patients with active disease, but only in 20% from those in inactive stages. The immunoglobulin/complement protein ratio differed from that seen in rheumatoid arthritis and in systemic lupus erythematosus, due to the relatively larger amounts of C3 and C4 present in the immune complexes. These findings indicate that circulating immune complexes in ankylosing spondylitis may not be of pathogenetic significance because of their degree of solubilization.

Antigen-Antibody Complex↗