The Cleveland Clinic-Nimbus total artificial heart. Design and in vitro function.

We describe the design and in vitro testing of the Cleveland Clinic-Nimbus electrohydraulic permanent total artificial heart as it nears completion of development. The total artificial heart uses an electric motor and hydraulic actuator to drive two diaphragm-type blood pumps. The interventricular space contains the pump control electronics and is vented to an air-filled compliance chamber. Pericardial tissue valves and biolized blood-contacting surfaces potentially eliminate the need for anticoagulation. In vitro studies on a mock circulatory circuit demonstrated preload-sensitive control of pump output over the operating range of the blood pump: 70 to 160 beats/min and 5 to 9.6 L/min at right and left atrial pressures of 1.0 to 7.0 mm Hg and 5.0 to 12.0 mm Hg, respectively. The pump output was found to be insensitive to afterload over a range of 15 to 40 mm Hg mean pulmonary artery pressure and 60 to 130 mm Hg mean systemic pressure. The left master alternate control mode balanced the ventricular outputs during simulated bronchial artery shunting of up to 20% of cardiac output. A 10% to 15% right-pump, stroke-volume limiter balanced ventricular outputs during maximum output of 9.6 L/min. In response to a sustained increase in systemic venous return, the pump increased output by 2 L/min (29%) in 35 seconds. Thus the Cleveland Clinic-Nimbus total artificial heart meets the National Heart, Lung, and Blood Institute hemodynamic performance goals for devices being developed for permanent heart replacement. The biolized blood-contacting surfaces should decrease the risk of thromboembolism associated with circulatory assist devices.

Cardiac Output↗

Hemodynamic changes with posture in calves with total artificial heart.

Hemodynamic changes with posture, sitting versus standing, were analyzed in five Holstein calves with the Cleveland Clinic-Nimbus TAH. This total artificial heart (TAH) has a left master alternate control mode that adjusts the pump rate and consequently pump flow proportional to the pulmonary venous return to the left pump (AUTO period). However, in this series of experiments, the pump reached its maximum beat rate within 1-5 days post operatively, after which pump flow could not increase (MAX period). Hemodynamic parameters (RAP, LAP, PAP, AoP, and pump flow) were obtained every 15-20 min throughout the experiments for as long as 120 days and averaged for each posture for each period. During the AUTO period, the flow while standing was significantly higher than that while sitting (standing: 8.7 +/- 0.2 L/min; sitting: 7.5 +/- 0.4 L/min; p < 0.05), and the systemic vascular resistance (SVR) was significantly lower (standing: 895 +/- 93 dyne.sec.m-5; sitting: 1,041 +/- 124 dyne.sec.m-5; p < 0.05). During the MAX period, the AoP and SVR standing were significantly lower than those sitting (AoP standing: 91 +/- 7 mmHg; AoP sitting: 98 +/- 7 mmHg; p < 0.05; SVR standing: 652 +/- 75 mmHg; SVR sitting: 730 +/- 96 mmHg; p < 0.05). The Cleveland Clinic-Nimbus TAH responded well to these changes in position, increasing pump flow and maintaining the AoP during the AUTO period.

Animals↗

Effects of a total artificial heart right stroke volume limiter on left-right hemodynamic balance.

In a completely implantable total artificial heart (TAH), the left-right flow difference attributable to higher volumetric efficiency of the right pump and bronchial artery shunting has always been a significant problem. The automatic control of the Cleveland Clinic-Nimbus TAH accommodates for the left-right flow difference when the beat rate is below maximum (AUTO range). However, at its maximum beat rate (MAX), high left atrial pressure (LAP) (greater than 25 mmHg) with relatively low right atrial pressure (RAP) (less than 8 mmHg) were observed both in vitro and in vivo, suggesting the need for a stroke volume limiter (SVL) of the right pump. In vitro volume loading tests showed 10%, 15%, and 20% SVLs prevented a disproportionate increase of LAP. In vivo studies in five Holstein calves also showed a balanced LAP-RAP relationship with 10% and 15% SVLs at MAX. The left pump flow was not affected by this range of SVLs either in vitro or in vivo. Pulmonary function was maintained with either size SVL, with autopsies revealing absence of pulmonary congestion and minimal pleural effusions in two calves surviving for more than 1 month. Although additional studies are needed to determine the appropriate size of the SVL, both 10% and 15% SVLs were effective in maintaining left-right hemodynamic balance in this TAH.

Animals↗