PubMed Health⌕ Search

Biomedical subjects

S J Brecker

Publications and source records attributed to S J Brecker.

At least 19 recordsLinked to original sources

Dobutamine stress echocardiography and cardiac troponin T for the detection of significant coronary artery disease and predicting outcome in renal transplant candidates.

AIMS: Ischaemic heart disease is the leading cause of mortality and morbidity in patients with end-stage renal disease (ESRD) and after renal transplantation. However, the optimal non-invasive test for coronary artery disease (CAD) diagnosis in this population has yet to be established. The aim of this study was to assess the diagnostic accuracy of dobutamine stress echocardiography (DSE) and baseline plasma cardiac troponin T (cTnT) for detecting significant CAD and predicting adverse cardiac events in patients referred for renal transplantation. METHODS: Coronary angiography, DSE, and baseline cTnT measurements were performed in 118 consecutive patients (mean age 52+/-12 years, 75 male) with ESRD (mean creatinine 608+/-272 micromol/L) referred for renal transplantation. The mean follow-up period was 1.32+/-0.48 years. Significant CAD was defined as a reduction in luminal diameter >70% by visual estimation in at least one major epicardial vessel. An abnormal DSE result defined as the development of a new regional wall motion abnormality in one or more normal resting segments or a deterioration of wall motion in one or more resting hypokinetic segments. A baseline cTnT>0.1 microg/L was taken as positive. RESULTS: Significant CAD in at least one vessel was present in 35 patients (30%). The number of patients with significant 3 vessel and 2 vessel disease was 6 and 7, respectively. An abnormal DSE result was present in 36 (31%) patients. Thirty-one (26%) had cTnT>0.1 microg/L. Sixty-four (54%) patients were on dialysis and 46 (39%) were diabetic. The sensitivity, specificity, positive and negative predictive values for DSE in detecting significant coronary artery disease were 88%, 94%, 86% and 95%, respectively. The same values for a raised cTnT were 54%, 62%, 40% and 74%, respectively. The combination of an abnormal DSE result and raised cTnT gave values of 61%, 91%, 76%, and 80%, respectively. Over the follow-up period, mortality was significantly higher in those with a raised baseline cTnT but not those with an abnormal DSE result or significant CAD. CONCLUSION: DSE is an accurate technique for the detection of significant CAD in renal transplant candidates. An elevated cTnT does not predict significant CAD in this population and when used in conjunction with DSE, reduces the sensitivity of the combined tests. cTnT is an important marker of prognosis in renal transplant candidates.

Adult↗

Closure of defects of the atrial septum in adults using the Amplatzer device: 100 consecutive patients in a single center.

BACKGROUND: Transcatheter device closure of atrial septal defects (ASD) is an alternative to surgery, but experience is limited in adults, especially in those with large (> 26 mm) defects. HYPOTHESIS: We investigated the safety, efficacy, and learning curve for closure of ASD and patent foramen ovale (PFO) using the Amplatzer device. METHODS: In all, 101 procedures were carried out in 100 consecutive adult patients in a single cardiac center between July 1998 and August 2002. RESULTS: Preprocedure diagnosis was ASD and PFO in 50 patients each. A device was deployed in 94 of 101 attempts (93%) in 94 of 100 patients (94%). Atrial septal defect device sizes were 10-38 mm, median 24 mm, and 40% were > 26 mm. Major complications occurred in 2 of 100 patients (2%). One ASD device displaced requiring surgery within 24 h and one patient with PFO experienced pericardial tamponade; there were no deaths. Local vascular complications occurred in 4 of 100 (4%) and late complications in 4 of 100 (4%) patients. Patent foramen ovale closure was quicker (p<0.001), required less radiation (p=0.04), and was associated with fewer local vascular complications than ASD closure (p=0.04). Deployment of ASD devices > 26 mm was not associated with increased complications, length of procedure, or radiation compared with devices < or = 26 mm (all p>0.05). Complications in the first 35 patients were more frequent than in subsequent patients: 7 of 35 (20%) versus 3 of 65 (4.6%) (p=0.04); procedure and fluoroscopy times (both p<0.001) and radiation doses (p=0.001) were also higher. CONCLUSION: The Amplatzer device is an effective method for transcatheter closure of interatrial defects in adults, including large ASDs up to 38 mm. Major complications are uncommon. A learning curve of approximately 35 cases was suggested by the decline of complications, procedure times, and radiation exposure.

Adult↗

Septal myotomy-myectomy and transcoronary septal alcohol ablation in hypertrophic obstructive cardiomyopathy. A comparison of clinical, haemodynamic and exercise outcomes.

AIMS: Surgical myectomy has been successfully used to treat patients with symptomatic obstructive hypertrophic cardiomyopathy (HCM). More recently, alcohol septal ablation has been advocated as a less invasive, but equally effective alternative therapy. The aim of this non-randomized cohort study was to compare subjective and objective outcomes in patients undergoing these therapies. METHODS: Forty-four patients (25 male; age 41+/-15 years) with symptomatic drug-refractory obstructive HCM were studied. Twenty-four patients underwent surgical myectomy and 20 alcohol septal ablation. All patients underwent clinical evaluation, echocardiography and upright maximal cardiopulmonary exercise testing using a cycle ergometer before and following their intervention. RESULTS: Peak gradient was reduced to a similar extent by both modalities (myectomy: 83+/-23 to 15+/-10 mmHg (P<0.000001); ablation: 91+/-18 to 22+/-14 mmHg (P<0.000002);P =0.48 for myectomy vs ablation) and led to similar improvements in NYHA class (myectomy: 2.4+/-0.6 to 1.5+/-0.7 (P<0.00001); ablation: 2.3+/-0.5 to 1.7+/-0.8 (P<0.0001);P=0.3 for myectomy vs ablation). Myectomy resulted in a greater improvement in peak oxygen consumption (myectomy: 16.4+/-5.8 to 23.1+/-7.1 ml.kg(-1) min(-1) (P<0.00002); ablation: 16.2+/-5.2 to 19.3+/-6.1 ml.kg(-1) min(-1) (P<0.05);P <0.05 for myectomy vs ablation) and work rate achieved (myectomy: 130+/-57 to 161+/-60 watts (P<0.04); ablation: 121+/-53 to 137+/-51 watts (P=0.11);P <0.05 for myectomy vs ablation). CONCLUSION: Surgical myectomy and alcohol septal ablation are equally effective at reducing obstruction and subjective exercise limitation in appropriately selected patients. However, the superior effect of surgical myectomy on exercise test parameters suggests that surgery remains the gold standard against which new treatment modalities should be compared.

Adult↗

Left ventricular opacification during selective intracoronary injection of echocardiographic contrast in patients with hypertrophic cardiomyopathy.

Percutaneous alcohol ablation of the interventricular septum via the first septal perforator branch of the left anterior descending artery can successfully treat dynamic left ventricular outflow tract obstruction in patients with hypertrophic cardiomyopathy. Increasingly, echocardiographic contrast agents are used before alcohol injection to identify the perfusion bed of the septal perforator vessels. This study describes the unexpected opacification of the left ventricular cavity in three of five consecutive patients following selective injection of the first septal perforator with Optison. This case study demonstrates that direct communication between the first septal perforator vessel and the left ventricle is common, an observation that may have considerable relevance to the technique of alcohol septal reduction.

Adult↗

Successful treatment of Staphylococcus lugdunensis endocarditis complicated by multiple emboli: a case report and review of the literature.

We describe the prompt diagnosis and successful treatment of mitral valve endocarditis in a 52-year-old woman due to a recently described coagulase negative staphylococcus, Staphylococcus lugdunensis. Endocarditis due to this organism has a high mortality rate with 8 out of 12 published cases ending in fatality. Review of the literature revealed that use of commercial identification systems can lead to misidentification of Staphylococcus lugdunensis and consequently delay appropriate treatment. It is clinically important to distinguish Staphylococcus lugdunensis from other coagulase negative staphylococci by detailed microbiological testing. The awareness of this from of endocarditis and its natural history is important since it differs significantly from other coagulase negative staphylococci. It highlights the need for early surgical intervention not only for haemodynamic complications but also for recurrent emboli. Multiple emboli appears to be a frequent finding on review of the literature.

Anti-Bacterial Agents↗

A comparison of left ventricular myocardial velocity in diastole measured by magnetic resonance and left ventricular filling measured by Doppler echocardiography.

Abnormal diastolic left ventricular function is an early marker for myocardial disease and may be impaired even when global systolic function is normal. Subendocardial function is affected early in ischaemic heart disease and by altering left ventricular long axis motion, may contribute to abnormal transmitral pressure gradients. Regional myocardial long axis velocity in diastole measured by magnetic resonance was compared with left ventricular filling measured by Doppler echocardiography in 25 patients with coronary artery disease. Fifteen patients also underwent magnetic resonance assessment at the time of onset of early diastolic blood flow. The onset of diastolic long axis velocity preceded flow across the mitral valve by a mean of 46 ms. Mean long axis myocardial velocity correlated with peak early filling velocity (E) (r = 0.73, P < 0.001), early deceleration (r = -0.73, P < 0.001), and the early to late filling ratio (E/A) ratio (r = 0.6, P < 0.01). Maximum myocardial long axis velocity also correlated with peak early filling velocity (r = 0.56, P < 0.01), early deceleration rate (r = 0.63, P < 0.001), and the E/A ratio (r = 0.53, P < 0.01). The variability of long axis velocity around the ventricle correlated inversely with peak early filling, (r = -0.7, P < 0.001), early deceleration (r = -0.56, P < 0.01), and the E/A ratio (r = -0.48, P < 0.02). Peak atrial filling velocity did not correlate with any measure of long axis myocardial velocity. We conclude that early diastolic long axis myocardial velocity has a significant effect on left ventricular filling.

Adult↗

Anatomical definition of aortic root abscesses by transesophageal echocardiography: planning a surgical strategy using homograft valves.

Infective endocarditis of the native or a prosthetic aortic valve may be complicated by abscess cavity development in the aortic root, and successful treatment depends upon early diagnosis, clear anatomical definition preoperatively, and maintaining sterility of the second implant. Homograft valves offer many advantages in this setting. Timing of surgery and the choice of the particular technique depends on accurate characterization of the anatomical details of the abscess. Five cases of paravalvular aortic root abscess in the setting of prosthetic valve endocarditis are described. In each case the diagnosis was made with transesophageal echocardiography, and the information was used in planning the operative procedure of homograft valve replacement. This strategy is proposed as optimal management of this potentially lethal condition.

Abscess↗

Early changes in left ventricular function after aortic valve replacement for isolated aortic stenosis.

To assess the immediate effects of aortic valve replacement (AVR) for valvular aortic stenosis (AS) on left ventricular (LV) systolic and diastolic function and global hemodynamics, 17 patients with AS underwent transesophageal echocardiography combined with high-fidelity LV pressure recording and thermodilution cardiac output measurements before cardiopulmonary bypass and 0.5, 6, 12, and 20 hours after AVR. Compared with results before bypass, LV systolic function had already changed 30 minutes after AVR, and remained constant thereafter: peak LV systolic wall stress decreased (from 210 +/- 60 to 130 +/- 40 g.cm-2), peak rate of dimension shortening increased (from 7.3 +/- 2.2 to 9.7 +/- 2.1 cm.s-1), both p < 0.01. Peak segmental external power thus remained constant (16.6 +/- 6.7 vs 17.7 +/- 7.6 mW.cm-3); p = NS. Changes in LV diastolic function and global hemodynamics were delayed. The peak rate of ventricular pressure decrease, normalized to developed end-systolic pressure, increased (from 15 +/- 3.2 to 19 +/- 5.2 s-1) by 6 hours. The minimal ventricular pressure of early diastole decreased (from 8.9 +/- 4.9 to 4.3 +/- 3.7 mm Hg), the peak rate of dimension lengthening of early diastole increased (from 6.0 +/- 3.0 to 8.8 +/- 2.0 cm.s-1), and LV stroke volume index increased (from 24 +/- 7 to 31 +/- 6 ml.m-2) by 12 hours, all p < 0.01. LV incoordination, defined as the dimension changes during isovolumic periods, had also improved significantly at 20 hours. Heart rate and LV enddiastolic dimension did not change.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Bedside assessment of myocardial performance in the critically ill.

No measurement of myocardial performance currently available in the ICU can be regarded is ideal. Table 2 summarises the main features of the major monitoring techniques. As many of the indices of myocardial performance are interdependent, quantifying the contribution of each component to overall cardiac function is not possible currently, and the clinical utility of monitoring each individually is not therefore established. Bedside measurements of LV dimensions, volumes and ejection fraction, and the other indices of systolic and diastolic function can now be made, but the case for their routine use in influencing clinical practice remains unproven. Transoesophageal echocardiography has an important and established diagnostic role and has been used successfully for continuous monitoring during surgery, but practical considerations seriously limit its potential for routine use. Radionuclide techniques allow the measurement of many of the same parameters and have the potential for continuous use, but practical problems and the additional risk of radiation exposure may limit this application in the critical care environment. Doppler techniques are non-invasive, provide continuous data and are simple to operate, but the data provided has important limitations. Although the pulmonary artery catheter has been in use for over twenty years, questions regarding the information is provides concerning myocardial function remain and the extent to which it should influence therapeutic decisions is still controversial. However with the development of additional facilities, particularly the continuous measurement of cardiac output the pulmonary artery catheter seems likely to remain the mainstay of bedside monitoring of myocardial performance in the critically ill in the immediate future.

Cardiac Output↗