PubMed Health⌕ Search

Biomedical subjects

S J Connolly

Publications and source records attributed to S J Connolly.

At least 19 recordsLinked to original sources

Effects of magnesium on atrial fibrillation after cardiac surgery: a meta-analysis.

OBJECTIVES: To assess the efficacy of the administration of magnesium as a method for the prevention of postoperative atrial fibrillation (AF) and to evaluate its influence on hospital length of stay (LOS) and mortality. METHODS: Literature search and meta-analysis of the randomised control studies published since 1966. RESULTS: 20 randomised trials were identified, enrolling a total of 2490 patients. Study sample size varied between 20 and 400 patients. Magnesium administration decreased the proportion of patients developing postoperative AF from 28% in the control group to 18% in the treatment group (odds ratio 0.54, 95% confidence interval (CI) 0.38 to 0.75). Data on LOS were available from seven trials (1227 patients). Magnesium did not significantly affect LOS (weighted mean difference -0.07 days of stay, 95% CI -0.66 to 0.53). The overall mortality was low (0.7%) and was not affected by magnesium administration (odds ratio 1.22, 95% CI 0.39 to 3.77). CONCLUSION: Magnesium administration is an effective prophylactic measure for the prevention of postoperative AF. It does not significantly alter LOS or in-hospital mortality.

Anti-Arrhythmia Agents↗

Physiologic pacing: where pacing mode selection reflects the indication.

Results of recent trials suggest that in patients with left ventricular dysfunction, interventricular synchrony is possibly more important than atrioventricular synchrony. In patients with AV block and conduction system disease, alternatives to right ventricular apical pacing are therefore needed.

Arrhythmias, Cardiac↗

Dose-response relations of azimilide in the management of symptomatic, recurrent, atrial fibrillation.

We evaluated the efficacy and safety of azimilide, a new class III antiarrhythmic agent that blocks both the slow and fast components of the cardiac-delayed rectifier potassium currents in 4 randomized, double-blind, placebo-controlled trials with similar protocols. The purpose of this study was to assess the relation between dose and effect. A total of 1,380 patients with a documented history of symptomatic atrial fibrillation (AF), atrial flutter, or both, were enrolled. After a 3-day loading period during which the assigned dose was given twice a day, subjects received placebo or azimilide (35, 50, 75, 100, or 125 mg once a day) for the duration of the study period. The primary end point of the studies was the time to symptomatic arrhythmia recurrence with a transtelephonic electrocardiogram typical of AF, atrial flutter, or paroxysmal supraventricular tachycardia. For each study, Kaplan-Meier estimates of the median time to recurrence were computed for placebo and for each azimilide dose. Cox proportional-hazards modeling was used to estimate hazard ratios for each active dose. Each of the 2 highest azimilide doses (100 and 125 mg/day) significantly prolonged the time to recurrence of arrhythmia. For the 100 mg/day dose, the hazard ratio was 1.34, 95% confidence interval 1.05 to 1.72; p = 0.02. For the 125 mg/day dose, the hazard ratio was 1.32, 95% confidence interval 1.07 to 1.62; p = 0.01. Patients with a history of either ischemic heart disease or congestive heart failure had a significantly greater treatment effect from azimilide than those without it. Torsades de Pointes occurred in 0.9% of patients receiving either of the 2 effective doses. Thus, doses of azimilide <100 mg/day are not effective for control of AF, whereas doses of 100 and 125 mg/day are effective with an acceptable risk of serious toxicity.

Aged↗

Effect of clinical risk stratification on cost-effectiveness of the implantable cardioverter-defibrillator: the Canadian implantable defibrillator study.

BACKGROUND: Three randomized clinical trials showed that implantable cardioverter-defibrillators (ICDs) reduce the risk of death in survivors of ventricular tachyarrhythmias, but the cost per year of life gained is high. A substudy of the Canadian Implantable Defibrillator Study (CIDS) showed that 3 clinical factors, age >/=70 years, left ventricular ejection fraction </=35%, and New York Heart Association class III, predicted the risk of death and benefit from the ICD. We estimated the extent to which selecting patients for ICD therapy based on these risk factors makes ICD therapy more economically attractive. METHODS AND RESULTS: Patients in CIDS were grouped according to whether they had >/=2 of 3 risk factors. Incremental cost-effectiveness of ICD therapy was computed as the ratio of the difference in mean cost to the difference in life expectancy between the 2 groups. Over 6.3 years, the mean cost per patient in the ICD group was Canadian (C) $87 715 versus $38 600 in the amiodarone group (C$1 approximately US$0.67). Life expectancy for the ICD group was 4.58 years versus 4.35 years for amiodarone, for an incremental cost-effectiveness of ICD therapy of C$213 543 per life-year gained. The cost per life-year gained in patients with >/=2 factors was C$65 195, compared with C$916 659 with <2 risk factors. CONCLUSIONS: The cost-effectiveness of ICD therapy varies by patient risk factor status. The use of ICD therapy in patients who have >/=2 risk factors of age >/=70 years, left ventricular ejection fraction </=35%, and NYHA class III is C$65 195 to gain a year of life.

Aged↗

Relationship between pacemaker dependency and the effect of pacing mode on cardiovascular outcomes.

BACKGROUND: A recently completed trial, the Canadian Trial of Physiological Pacing (CTOPP), showed that physiological pacing did not significantly reduce mortality, stroke, or heart failure hospitalization, but it did show that atrial fibrillation occurred less frequently in patients with physiological pacing. Many pacemaker patients experience only transient bradyarrhythmias with an adequate unpaced heart rate (UHR) and are not pacemaker-dependent. The purpose of the present analysis was to determine if pacemaker-dependent patients have an increased benefit from physiological pacing compared with non-pacemaker-dependent patients. METHODS AND RESULTS: Of 2568 patients included in the CTOPP trial, 2244 patients had a pacemaker dependency test performed at the first follow-up visit. The yearly event rate of cardiovascular death or stroke steadily increased with decreasing UHR in the ventricular pacing group, but it remained constant in the physiological pacing group. When the patients were subdivided to UHR </=60 bpm or >60 bpm, there was an interaction between pacing mode treatment and UHR subgroup. The Kaplan-Meier plot confirmed a physiological pacing advantage only in the UHR </=60 bpm subgroup. This differential effect was also present for the outcomes of cardiovascular death and total mortality. CONCLUSIONS: This study demonstrated that UHR at first follow-up has an important influence on how pacing mode selection affects cardiovascular death and total mortality. Pacemaker-dependent patients with low UHR will probably be paced frequently and will likely benefit from physiological pacing. In contrast, non-pacemaker-dependent patients will likely be paced infrequently and may not benefit from physiological pacing.

Aged↗

New-onset atrial fibrillation: sex differences in presentation, treatment, and outcome.

BACKGROUND: Although sex differences in coronary artery disease have received considerable attention, few studies have dealt with sex differences in the most common sustained cardiac arrhythmia, atrial fibrillation (AF). Differences in presentation and clinical course may dictate different approaches to detection and management. We sought to examine sex-related differences in presentation, treatment, and outcome in patients presenting with new-onset AF. METHODS AND RESULTS: The Canadian Registry of Atrial Fibrillation (CARAF) enrolled subjects at the time of first ECG-confirmed diagnosis of AF. Participants were followed at 3 months, at 1 year, and annually thereafter. Treatment was at the discretion of the patients' physicians and was not directed by CARAF investigators. Baseline and follow-up data collection included a detailed medical history, clinical, ECG, and echocardiographic measures, medication history, and therapeutic interventions. Three hundred thirty-nine women and 560 men were followed for 4.14+/-1.39 years. Compared with men, women were older at the time of presentation, more likely to seek medical advice because of symptoms, and experienced significantly higher heart rates during AF. Compared with older men, older women were half as likely to receive warfarin and twice as likely to receive acetylsalicylic acid. Compared with men on warfarin, women on warfarin were 3.35 times more likely to experience a major bleed. CONCLUSIONS: Anticoagulants are underused in older women with AF relative to older men with AF, despite comparable risk profiles. Women receiving warfarin have a significantly higher risk of major bleeding, suggesting the need for careful monitoring of anticoagulant intensity in women.

Anticoagulants↗

Circadian variation of paroxysmal atrial fibrillation. PA3 Investigators. Atrial Pacing Peri-ablation for Prevention of Atrial Fibrillation Trial.

The circadian variation of paroxysmal atrial fibrillation (AF) was studied in 67 patients who received a dual-chamber pacemaker 3 months before a planned atrioventricular node ablation. A distinct circadian variation of AF was observed with 2 time peaks in initiation (1 in the early morning and 1 in the early evening hours), which was modulated by atrial pacing, the duration of AF, and the use of beta-adrenergic blocking agents.

Amiodarone↗

Cost-effectiveness of the implantable cardioverter-defibrillator: results from the Canadian Implantable Defibrillator Study (CIDS).

BACKGROUND: In the Canadian Implantable Defibrillator Study (CIDS), we assessed the cost-effectiveness of the implantable cardioverter-defibrillator (ICD) in reducing the risk of death in survivors of previous ventricular tachycardia (VT) or fibrillation (VF). METHODS AND RESULTS: Healthcare resource use was collected prospectively on the first 430 patients enrolled in CIDS (n=212 ICD, n=218 amiodarone). Mean cost per patient, adjusted for censoring, was computed for each group based on initial therapy assignment. Incremental cost-effectiveness of ICD therapy was computed as the ratio of the difference in cost (ICD minus amiodarone) to the difference in life expectancy (both discounted at 3% per year). All costs are in 1999 Canadian dollars (C$1 approximately US$0.65). Over 6.3 years, mean cost per patient in the ICD group was C$87 715 versus C$38 600 in the amiodarone group (difference C$49 115; 95% CI C$25 502 to C$69 508). Life expectancy for the ICD group was 4.58 years versus 4.35 years for amiodarone (difference 0.23, 95% CI -0.09 to 0.55), for incremental cost-effectiveness of ICD therapy of C$213 543 per life-year gained. ICD benefit was greater in patients with low left ventricular ejection fraction (<35%), and cost-effectiveness in this group was more attractive (C$108 484). Alternative extrapolations of survival benefit and costs to 12 years indicated cost-effectiveness in the range of C$100 000 to C$150 000 per life-year gained. CONCLUSIONS: At C$213 543, the value for the money offered by ICD therapy is not attractive by currently accepted standards. Further research is warranted to identify the indications and patient subgroups for whom ICDs are a cost-effective use of resources.

Cost-Benefit Analysis↗

Progression to chronic atrial fibrillation after pacing: the Canadian Trial of Physiologic Pacing. CTOPP Investigators.

OBJECTIVES: This study examined the effect of physiologic pacing on the development of chronic atrial fibrillation (CAF) in the Canadian Trial Of Physiologic Pacing (CTOPP). BACKGROUND: The role of physiologic pacing to prevent CAF remains unclear. Small randomized studies have suggested a benefit for patients with sick sinus syndrome. No data from a large randomized trial are available. METHODS: The CTOPP randomized patients undergoing first pacemaker implant to ventricular-based or physiologic pacing (AAI or DDD). Patients who were prospectively found to have persistent atrial fibrillation (AF) lasting greater than or equal to one week were defined as having CAF. Kaplan-Meier plots for the development of CAF were compared by log-rank test. The effect of baseline variables on the benefit of physiologic pacing was evaluated by Cox proportional hazards modeling. RESULTS: Physiologic pacing reduced the development of CAF by 27.1%, from 3.84% per year to 2.8% per year (p = 0.016). Three clinical factors predicted the development of CAF: age > or =74 years (p = 0.057), sinoatrial (SA) node disease (p < 0.001) and prior AF (p < 0.001). Subgroup analysis demonstrated a trend for patients with no history of myocardial infarction or coronary disease (p = 0.09) as well as apparently normal left ventricular function (p = 0.11) to derive greatest benefit. CONCLUSIONS: Physiologic pacing reduces the annual rate of development of chronic AF in patients undergoing first pacemaker implant. Age > or =74 years, SA node disease and prior AF predicted the development of CAF. Patients with structurally normal hearts appear to derive greatest benefits.

Aged↗

Randomized crossover comparison of DDDR versus VDD pacing after atrioventricular junction ablation for prevention of atrial fibrillation. The atrial pacing peri-ablation for paroxysmal atrial fibrillation (PA (3)) study investigators.

BACKGROUND: Some clinical data suggest that atrial-based pacing prevents paroxysmal atrial fibrillation (AF). This study tested the hypothesis that DDDR pacing compared with VDD pacing prevents AF after atrioventricular (AV) junction ablation. METHODS AND RESULTS: Patients were randomized to DDDR pacing (n=33) or to VDD pacing (n=34) after AV junction ablation and followed every 2 months for 6 months. Patients then crossed over to the alternate pacing mode and were followed for an additional 6 months. Primary analysis included the time to first recurrence of sustained AF (duration >5 minutes), total AF burden, and the development of permanent AF. The time to first episode of AF was similar in the DDDR group (0.37 days, 95% CI 0.1 to 1.3 days) and the VDD pacing group (0.5 days, 95% CI 0.2 to 1.7 days, P=NS). AF burden increased over time in both groups (P<0.01). At the 6-month follow-up, AF burden was 6.93 h/d (95% CI 4. 37 to 10.96 h/d) in the DDDR group and 6.30 h/d (95% CI 3.99 to 9.94 h/d) in the VDD group (P=NS). Twelve (35%) patients in the DDDR group and 11 (32%) patients in the VDD group had permanent AF within 6 months of ablation. Within 1 year of follow-up, 43% of patients had permanent AF. CONCLUSIONS: DDDR pacing compared with VDD pacing does not prevent paroxysmal AF over the long term in patients in the absence of antiarrhythmic drug therapy after total AV junction ablation. Many patients have permanent AF within the first year after ablation.

Aged↗

Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. Canadian Trial of Physiologic Pacing Investigators.

BACKGROUND: Evidence suggests that physiologic pacing (dual-chamber or atrial) may be superior to single-chamber (ventricular) pacing because it is associated with lower risks of atrial fibrillation, stroke, and death. These benefits have not been evaluated in a large, randomized, controlled trial. METHODS: At 32 Canadian centers, patients without chronic atrial fibrillation who were scheduled for a first implantation of a pacemaker to treat symptomatic bradycardia were eligible for enrollment. We randomly assigned patients to receive either a ventricular pacemaker or a physiologic pacemaker and followed them for an average of three years. The primary outcome was stroke or death due to cardiovascular causes. Secondary outcomes were death from any cause, atrial fibrillation, and hospitalization for heart failure. RESULTS: A total of 1474 patients were randomly assigned to receive a ventricular pacemaker and 1094 to receive a physiologic pacemaker. The annual rate of stroke or death due to cardiovascular causes was 5.5 percent with ventricular pacing, as compared with 4.9 percent with physiologic pacing (reduction in relative risk, 9.4 percent; 95 percent confidence interval, -10.5 to 25.7 percent [the negative value indicates an increase in risk]; P=0.33). The annual rate of atrial fibrillation was significantly lower among the patients in the physiologic-pacing group (5.3 percent) than among those in the ventricular-pacing group (6.6 percent), for a reduction in relative risk of 18.0 percent (95 percent confidence interval, 0.3 to 32.6 percent; P=0.05). The effect on the rate of atrial fibrillation was not apparent until two years after implantation. The observed annual rates of death from all causes and of hospitalization for heart failure were lower among the patients with a physiologic pacemaker than among those with a ventricular pacemaker, but not significantly so (annual rates of death, 6.6 percent with ventricular pacing and 6.3 percent with physiologic pacing; annual rates of hospitalization for heart failure, 3.5 percent and 3.1 percent, respectively). There were significantly more perioperative complications with physiologic pacing than with ventricular pacing (9.0 percent vs. 3.8 percent, P<0.001). CONCLUSIONS: Physiologic pacing provides little benefit over ventricular pacing for the prevention of stroke or death due to cardiovascular causes.

Aged↗

Canadian implantable defibrillator study (CIDS) : a randomized trial of the implantable cardioverter defibrillator against amiodarone.

BACKGROUND: Patients surviving ventricular fibrillation (VF) or sustained ventricular tachycardia (VT) are at a high risk of death due to a recurrence of arrhythmia. The implantable cardioverter defibrillator (ICD) terminates VT or VF, but it is not known whether this device prolongs life in these patients compared with medical therapy with amiodarone. METHODS AND RESULTS: A total of 659 patients with resuscitated VF or VT or with unmonitored syncope were randomly assigned to treatment with the ICD or with amiodarone. The primary outcome measure was all-cause mortality, and the secondary outcome was arrhythmic death. A total of 328 patients were randomized to receive an ICD. A thoracotomy was done in 33, no ICD was implanted in 18, and the rest had a nonthoracotomy ICD. All 331 patients randomized to amiodarone received it initially. At 5 years, 85.4% of patients assigned to amiodarone were still receiving it at a mean dose of 255 mg/day, 28.1% of ICD patients were also receiving amiodarone, and 21.4% of amiodarone patients had received an ICD. A nonsignificant reduction in the risk of death was observed with the ICD, from 10.2% per year to 8.3% per year (19.7% relative risk reduction; 95% confidence interval, -7.7% to 40%; P=0.142). A nonsignificant reduction in the risk of arrhythmic death was observed, from 4.5% per year to 3.0% per year (32.8% relative risk reduction; 95% confidence interval, -7.2% to 57.8%; P=0.094). CONCLUSIONS: A 20% relative risk reduction occurred in all-cause mortality and a 33% reduction occurred in arrhythmic mortality with ICD therapy compared with amiodarone; this reduction did not reach statistical significance.

Aged↗

Appropriate outcome measures in trials evaluating treatment of atrial fibrillation.

BACKGROUND: Atrial fibrillation (AF) is a widespread disease that has only recently received the focused attention of arrhythmia specialists despite being the most frequently occurring significant cardiac arrhythmia. METHODS AND RESULTS: The wide variety of trial designs used to evaluate AF treatment is a reflection of the diverse outcomes associated with this condition. The best trials assess the impact of treatment on a clearly measured outcome that is of clinical relevance to patients. This review discusses the different designs of AF treatment trials and analyzes the utility of the various outcomes that can be assessed. CONCLUSIONS: A sensible goal of AF treatment is to reduce the frequency of recurrences and to prolong the time between them. The most appropriate trials focus on AF recurrences that are symptomatic and therefore relevant to the patient. We still do not know if there is value in AF prevention, beyond preventing symptoms. However, ongoing and future studies will show whether AF suppression reduces the longer-term risks of stroke or death and improves patient quality of life. Cost of care will increasingly be studied in future trials of AF management.

Anti-Arrhythmia Agents↗

Clinical trials of pacing mode selection.

Current recommendations in favor of dual-chamber over single-chamber ventricular pacing for patients with sinus node dysfunction or AV conduction disorders were made largely based on observational data and expert opinions. The first randomized pacing mode selection study was relatively small and suggested survival advantage with physiologic pacing only after an extended follow-up duration of 5.5 years. Preliminary results of the first large-scale multicenter randomized pacing mode selection trial revealed only modest reduction in atrial fibrillation without survival advantage after 3 years of physiologic pacing. Two other large-scale multicenter randomized trials comparing physiologic versus ventricular pacing are currently ongoing. They may provide further scientific evidence based on which more objective recommendations can be made with respect to pacing mode selection.

Cardiac Pacing, Artificial↗