Gradient moment smoothing: a new flow compensation technique for multi-shot echo-planar imaging.

This work identifies an additional source of phase error across ky in multi-shot echo-planar imaging resulting from flow or motion along the phase-encoding direction. A velocity-independent flow compensation technique, gradient moment smoothing, is presented that corrects this error by forcing the phase to have smooth quadratic behavior. The correction is implemented, without compromising scan time, by changing the first moment of a bipolar prephaser pulse on a shot-by-shot basis. In phantom and in vivo experiments, gradient moment smoothing effectively eliminates ghosting and signal loss due to phase-encoding flow. When used in conjunction with a "flyback" echo-planar readout, which compensates for flow in the frequency-encoding direction, gradient moment smoothing renders multi-shot echo-planar imaging relatively insensitive to in-plane flow. This can make multi-shot echo-planar imaging a viable technique for accurately imaging in-plane flow and may desensitize it to the otherwise serious problem of in-plane motion.

Aorta, Thoracic↗

An orthogonal correlation algorithm for ghost reduction in MRI.

Ghosting in MRI due to modulation of k-space data can be caused by motion of the subject or characteristics of the sequence. A general solution for 2DFT MRI that reduces ghosting without causal modeling is presented. Separate image data sets are acquired in which the phase and frequency directions are swapped. In these two data sets, the image signal is correlated, whereas the ghost signals are not. By taking a correlation of these two data sets, an image with greatly reduced ghosting is obtained. The reduction is shown to depend both on the correct signal intensity of the image, as well as the ghost intensity in the ghosted region. The reduction approaches 100% in regions of low image signal, and is more moderate in regions of higher image signal. The process was applied to conventional spin-echo, fast-spin-echo, and gradient echo imaging of volunteers and a phantom. Results of a reader study of the volunteer images reflected a significant overall reduction of ghosting artifacts in all volunteer experiments.

Abdomen↗

Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging.

An elliptical centric phase-encoding (PE) order is applied to steady-state 3DFT imaging as performed during a single breath-hold or following contrast agent administration. In a set of simulation, phantom, and in vivo experiments, this truly centric PE order is shown to be both more resistant to breathing artifact and more capable of suppressing undesirable venous signals that can arise following peak arterial enhancement than a number of other centric PE techniques that are presently in use. Unlike other PE orders, the elliptical centric ordering changes with the relative dimensions of the two PE fields of view and is optimal based on increasing k-space radius. It thus creates a temporally diminishing importance to the PE order. The specific advantages of such an acquisition are demonstrated.

Artifacts↗

Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements.

Multiple element surface coils are often used in clinical MRI to increase the image signal-to-noise ratio (S/N). Use of multicoils typically requires increased net sampling bandwidth and data processing for each coil element. A phase-alignment technique is described which combines the signals from all coil elements before image reconstruction, greatly relaxing the technical requirements of the standard multicoil methods. Hardware and software implementations allow reduction of the reconstruction requirement to that of a single coil. The hardware implementation additionally allows a significant reduction in the net sampling bandwidth. The method is applicable to high speed MRI techniques, as demonstrated in phantoms and volunteers.

Magnetic Resonance Imaging↗

Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries.

PURPOSE: To determine the reliability of obtaining arterial-phase, contrast-material-enhanced three-dimensional (3D) magnetic resonance (MR) angiograms of the renal arteries by using a technique that combines two-dimensional real-time MR fluoroscopy and a 3D MR angiographic acquisition with elliptical centric view order. MATERIALS AND METHODS: Twenty-five consecutive patients suspected of having renal artery disease were evaluated with the fluoroscopically triggered technique by using a mean dose of 0.18 mmol/kg gadoteridol. Left renal vein suppression, inferior vena cava suppression, motion artifact, and image quality for depiction of the renal arteries were each evaluated on a five-point scale (1 = best). The findings were compared with those of another 25 consecutive patients who underwent conventional gadolinium-enhanced 3D MR angiography. RESULTS: The fluoroscopically triggered technique produced 4.6 times less left renal vein enhancement than did the conventional method (P < .01). With the fluoroscopically triggered technique, visualization of the renal arteries was adequate for diagnosis in 24 patients (96%) and the overall result (score of 1-3 for all criteria) was of good quality in 22 patients (88%). CONCLUSION: With this fluoroscopically triggered MR angiographic technique, high-quality, arterial phase, relatively motion immune angiograms can be routinely obtained.

Adolescent↗

The shoulder: adaptive motion correction of MR images.

PURPOSE: To evaluate an adaptive-motion-correction technique to reduce global motion in shoulder magnetic resonance (MR) images. MATERIALS AND METHODS: In the adaptive-motion-correction technique, interleaved navigator echoes are used to provide a measure of view-to-view displacement along the craniocaudal direction for each image echo in the acquisition. The information is then retrospectively applied to the k-space data to correct for global shoulder motion. This algorithm was evaluated in a series of 143 consecutive patient shoulder examinations by comparing the original image set for each patient with the same image set after retrospective correction by means of this algorithm. RESULTS: The average amplitude of craniocaudal motion was 1.4 mm. Image degradation due to motion was apparent in 100 (70%) of the 143 examinations. Application of the adaptive-motion-correction technique improved image quality in 73 (73%) of these 100 examinations or 51% of all 143 examinations. CONCLUSION: Adaptive motion correction improved image quality in approximately three-quarters of the examinations in which motion was present.

Humans↗

Multiple breathhold 3D time-of-flight MR angiography of the renal arteries.

A technique is described for angiographic imaging of the renal arteries with acquisition performed over several periods of suspended respiration. The 3D Fourier transform (FT) gradient-echo angiographic sequence uses magnetization preparation and appropriately chosen delay times for background nulling and time-of-flight enhancement of the vasculature. The sequence was applied to 10 volunteers, each of whom was imaged in three ways: (i) over a series of breathholds in which feedback was provided to enable reproducible breathholding; (ii) over a series of breathholds with no feedback; and (iii) over continuous respiration. Results were evaluated by measuring the transverse extent of the well-delineated renal vasculature and by noting the distal extent of the vasculature branching (main, segmental, and interlobar branches). The transverse extent of renal vasculature visible with breathhold feedback, breathholding, and free breathing was 6.1 +/- 0.9 cm, 5.0 +/- 1.8 cm, and 4.0 +/- 1.4 cm, respectively (mean +/- SD). Breathhold feedback enabled visualization of segmental renal arteries bilaterally in all 10 volunteers.

Fourier Analysis↗

Algorithms for extracting motion information from navigator echoes.

Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least squares for extracting displacement information from motion-monitoring navigator echoes, using computer simulation and in vivo imaging. The least squares algorithm was determined to be of higher accuracy than the correlation algorithm against errors caused by noise and profile deformation.

Algorithms↗

Magnetic resonance imaging of transverse acoustic strain waves.

We describe a phase contrast based MRI technique with high sensitivity to cyclic displacement that is capable of quantitatively imaging acoustic strain waves in tissue-like materials. A formalism for considering gradient waveforms as basis functions to measure arbitrary cyclic motion waveforms is introduced. Experiments with tissue-like agarose gel phantoms show that it is possible to measure small cyclic displacements at a submicron level by an appropriate choice of the applied gradient basis function and to use this capability to observe the spatial and temporal pattern of displacements caused by acoustic strain waves. The propagation characteristics of strain waves are determined by the mechanical properties of the media. It is therefore possible to use this technique to noninvasively estimate material properties such as elastic modulus.

Acoustics↗

Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography.

New centric phase encoding orders are introduced for transient state three-dimensional MR imaging. Unlike previous centric orders, these variants are not fixed with respect to differences in the relative y and z fields of view, but are tailored to account for the, differential degrees of gradient dephasing in the Ky and Kz phase encoding directions and thus maintain the highest weighting for the most central k-space values. The new centric orders are compared with previous methods in both simulation and experimental magnetization-prepared MR angiography of the carotid and renal arteries. In comparison with other tested centric orders, the new methods provided better retention of true vessel shape caused by isotropic blurring across the phase encoding plane. In addition, the new methods provided increased contrast, with the degree of improvement over previous methods depending on vessel orientation, size, and degree of inflow.

Brain↗

Real-time adaptive motion correction in functional MRI.

Functional magnetic resonance imaging (fMRI) of the brain is often degraded by bulk head motion. Algorithms that address this by retrospective re-registration of images in an fMRI time series are all fundamentally limited by any motion that occurs through-plane. Here, a technique is described that can account for such motion by prospective correction in real time. A navigator echo is used before every image acquisition to detect superior/inferior displacements of the head. The displacement information is then used to adjust the plane of excitation of the ensuing single-shot echo-planar fMRI axial image. These correction updates can be completed in 100 mm with motion sensitivity at least as small as 0.5 mm. The efficacy of this method is documented in phantom and human studies.

Brain↗

3D MR angiography of pulmonary arteries using real-time navigator gating and magnetization preparation.

An ECG-triggered magnetization-prepared segmented 3D fast gradient echo sequence was developed to perform pulmonary arterial MR angiography. A selective inversion recovery pulse was used in the magnetization preparation to suppress venous vasculature. A real-time gating technique based on navigator echoes was implemented to reduce respiration effects. Pencil-beam navigator echoes were acquired immediately before and after the readout train and processed in real-time to dynamically measure the diaphragm position, which was used to control data acquisition with an accept-or-reject-reacquire logic. In a study of 10 volunteers, a gated 3D acquisition with 28 slices required on average approximately 4 min of acquisition time, and six to seven segmental arteries related to the interlobar trunk of the pulmonary artery were depicted. The use of SIR pulse reduced venous signal by 99%. The gated acquisitions were superior to the ungated acquisitions (n = 10, P < 0.005). The real-time navigator gating technique is effective for reduction of respiration effects and thereby makes high resolution 3D MRA of the pulmonary arteries feasible.

Algorithms↗

Cardiac magnetic resonance fluoroscopy.

A technique is described for high speed interactive imaging of the heart with either white or black blood contrast. Thirty-two views of a segmented, magnetization-prepared gradient echo sequence are acquired during diastole. Using three-quarter partial Fourier sampling, data for a complete 128 x 128 image are acquired in three cardiac cycles. High speed reconstruction provides an image update of each cardiac cycle 159 ms after measurement. An independent graphical user interface facilitates interactive control of section localization and contrast by permitting pulse sequence parameter modification during scanning. The efficiency and image quality of the cardiac MR fluoroscopy technique were evaluated in 11 subjects. Compared with the conventional graphic prescription method, the cardiac fluoroscopy technique provides an approximate eightfold reduction in the time required to obtain subject-specific double oblique sections. Image quality for these scout acquisitions performed during free breathing was sufficient to identify small cardiac structures.

Coronary Angiography↗

Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography.

PURPOSE: To test the hypothesis that respiration effects in three-dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Real-time respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real-time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory-gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.

Adult↗

Mesial temporal sclerosis: diagnosis with fluid-attenuated inversion-recovery versus spin-echo MR imaging.

PURPOSE: To compare the accuracy of a fluid-attenuated inversion-recovery (FLAIR) sequence with that of a conventional double spin-echo (SE) sequence in the identification of increased signal intensity of the hippocampus in mesial temporal sclerosis (MTS). MATERIALS AND METHODS: Three blinded reviewers independently graded the FLAIR and SE images in 36 patients with intractable complex partial seizures. Reproducibility was tested. At histopathologic examination, the criterion standard, 32 patients had MTS. RESULTS: The accuracy of FLAIR images was 97% versus 91% for SE images (P<.02). The radiologists preferred the contrast properties of FLAIR to those of SE images by a significant margin (P<.0001). Surgical to nonsurgical hippocampal contrast-to-noise ratio (C/N) measurements were better for the second echo of the SE sequence than for FLAIR (P<.002). Hippocampus-to-background tissue C/N was superior with FLAIR (P<.0001). CONCLUSION: FLAIR provides images with T2-weighted contrast and complete suppression of high signal intensity of CSF. Incorporation of a FLAIR sequence into the routine MR evaluation of patients with epilepsy is recommended.

Adult↗

Use of functional magnetic resonance imaging.

It has been the goal of this article to provide the reader with a brief background of fMRI, a basic understanding of the techniques of fMRI, and, more importantly, the potential for clinical and experimental studies using fMRI. In contrast to the limited number of installed PET and MEG units, the large installed base of MR imaging scanners (over 1000 installed at least at 1.5 T in the United States) makes fMRI potentially widely available. Initial studies (both clinical and experimental) have been validated and are reproducible in mapping the sensorimotor and visual cortices. The areas of language lateralization and memory are still preliminary at best. As methods to reduce the effects of head motion (due to both bulk head motion and physiologically induced motion) arise, the reliability of fMRI should improve, allowing for more definitive identification of task activation.

Brain Diseases↗

Medical imaging.

Explore the source record for details and available documents.

Diagnostic Imaging↗

The effect of respiration on the contrast and sharpness of liver lesions in MRI.

This work demonstrates the effects of through-plane motion due to respiration on contrast and sharpness of liver lesions in MRI. The effects of slice coverage with and without such respiratory motion is also reported. This work is comprised of two parts: a theoretical prediction of liver-lesion contrast and blur with and without respiration and an experimental validation using gel phantoms of the predicted results. Both theory and experiment show a loss of contrast, increasing with amplitude of the peak-to-peak motion. The loss of contrast for a 5-mm lesion at normal respiration of 15 mm peak-to-peak superior-inferior motion is approximately 10% with a low order sorted respiratory ordered phase encoding acquisition and approximately 50% for an unsorted acquisition. Lesion blur is greatest for the low order sorted acquisition while the unsorted and high sort acquisitions maintain edge definition. Breath-hold imaging is potentially superior to nonbreath-hold imaging in liver lesion contrast and edge definition, but is more sensitive to inadequate slice coverage.

Artifacts↗