PubMed Health⌕ Search

Biomedical subjects

S J van Noort

Publications and source records attributed to S J van Noort.

3 recordsLinked to original sources

High speed atomic force microscopy of biomolecules by image tracking.

An image-tracking procedure for atomic force microscopy is proposed and tested, which allows repeated imaging of the same area without suffering from lateral drift. The drift correction procedure is based on on-line cross-correlation of succeeding images. Using the image-tracking procedure allows zooming in on a small scan area over a long period and thus increases the frame rate inversely proportional to the scan area. Application of the procedure is demonstrated for diffusion of 5.4-kb DNA plasmids. With a scan area of 500 * 500 nm(2), a single plasmid can be imaged for more than 30 min at 4 s per frame, with a drift less than 10 nm. The high temporal resolution allows detailed analysis of the diffusion of DNA molecules. A diffusion coefficient of 30 nm(2)/s is found for most DNA molecules, though many molecules are temporally pinned to the mica surface, restricting diffusion.

Aluminum Silicates↗

Optimization of adhesion mode atomic force microscopy resolves individual molecules in topography and adhesion.

The force sensor of an atomic force microscope (AFM) is sensitive enough to measure single molecular binding strengths by means of a force-distance curve. In order to combine high-force sensitivity with the spatial resolution of an AFM in topography mode, adhesion mode has been developed. Since this mode generates a force-distance curve for every pixel of an image, the measurement speed in liquid is limited by the viscous drag of the cantilever. We have equipped our adhesion mode AFM with a cantilever that has a low viscous drag in order to reach pixel frequencies of 65 Hz. Optimized filtering techniques combined with an auto-zero circuitry that reduces the drift in the deflection signal, limited high- and low-frequency fluctuations in the height signal to 0.3 nm. This reduction of the height noise, in combination with a thermally stabilized AFM, allowed the visualization of individual molecules on mica with an image quality comparable to tapping mode. The lateral resolution in both the topography and the simultaneously recorded adhesion image are only limited by the size of the tip. Hardware and software position feedback systems allows individual molecules to be followed in time during more than 30 min with scan sizes down to 60 x 60 nm2.

Evaluation Studies as Topic↗

Direct visualization of dynamic protein-DNA interactions with a dedicated atomic force microscope.

Photolyase DNA interactions and the annealing of restriction fragment ends are directly visualized with the atomic force microscope (AFM). To be able to interact with proteins, DNA must be loosely bound to the surface. When MgCl2 is used to immobilize DNA to mica, DNA is attached to the surface at distinct sites. The pieces of DNA in between are free to move over the surface and are available for protein interaction. After implementation of a number of instrumental improvements, the molecules can be visualized routinely, under physiological conditions and with molecular resolution. Images are acquired reproducibly without visible damage for at least 30 min, at a scan rate of 2 x 2 microm2/min and a root mean square noise of less than 0.2 nm. Nonspecific photolyase DNA complexes were visualized, showing association, dissociation, and movement of photolyase over the DNA. The latter result suggests a sliding mechanism by which photolyase can scan DNA for damaged sites. The experiments illustrate the potential that AFM presents for modern molecular biology.

Binding Sites↗